Non-invasive measurement of brain neurotransmitter: One novel model

被引:0
|
作者
Wenshi, Li [1 ,2 ]
Shengli, Lu [2 ]
Longxing, Shi [2 ]
机构
[1] Suzhou Univ, Dept Microelect, Sch Elect & Informat Engn, Suzhou 215021, Peoples R China
[2] Southeast Univ, Natl ASIC Syst Engn Res Ctr, Nanjing 210096, Peoples R China
来源
CHINESE JOURNAL OF ELECTRONICS | 2008年 / 17卷 / 02期
关键词
brain neurotransmitter; otopoint; infrared image; wavelet analysis; medicament inducement; validity study;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Brain sciences require tools that can noninvasively measure the bio-energy of Brain neurotransmitters (BNs). First we review the key models behind these tools, then to report one novel model OIIWA on otopoint's infrared image and wavelet analysis. Based on our model we provide a new investigative tool probe with 10-order wavelet coefficients corresponding to BNs in mHz level fluctuating, at last to select the medicament inducement as validity experiments for verifying the accuracy through the brain window of OIIWA. The data come from 10-subjective confirmed that our model validity be 90%.
引用
收藏
页码:270 / 272
页数:3
相关论文
共 50 条
  • [1] Non-invasive measurement of brain neurotransmitter: One novel model
    Department of Microelectronics, School of Electronics and Information Engineering, Suzhou University, Suzhou 215021, China
    不详
    Chin J Electron, 2008, 2 (270-272):
  • [2] Non-invasive measurement of brain damage in a primate model of multiple sclerosis
    't Hart, BA
    Vogels, J
    Bauer, J
    Brok, HPM
    Blezer, E
    TRENDS IN MOLECULAR MEDICINE, 2004, 10 (02) : 85 - 91
  • [3] Brain neurotransmitter non-invasive measurement validity: Auricular point's infrared image and wavelet analysis
    Li, Wenshi
    Su, Xiang
    2006 8TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, VOLS 1-4, 2006, : 2472 - +
  • [4] Non-invasive brain stimulation is not non-invasive
    Davis, Nick J.
    van Koningsbruggen, Martijn G.
    FRONTIERS IN SYSTEMS NEUROSCIENCE, 2013, 7
  • [5] Model for non-invasive cardiac output measurement
    Wassertheurer, Siegfried
    Mayer, Christopher
    Breitenecker, Felix
    AMS 2007: FIRST ASIA INTERNATIONAL CONFERENCE ON MODELLING & SIMULATION ASIA MODELLING SYMPOSIUM, PROCEEDINGS, 2007, : 580 - +
  • [6] Non-invasive measurement of functional optical brain changes
    Grattan, G
    Fabiani, M
    Foundations of Augmented Cognition, Vol 11, 2005, : 204 - 204
  • [7] A NOVEL NON-INVASIVE TECHNOLOGY FOR LIVER FIBROSIS MEASUREMENT
    Chen, Hao
    Wu, Shengdi
    Li, Zhenyan
    Klimov, Sergey
    Farris, Alton
    Jiang, Wei
    Jiang, Yi
    HEPATOLOGY, 2019, 70 : 1078A - 1078A
  • [8] A novel approach to non-invasive measurement of cardiac output
    Klein, Michael
    Machina, Matt
    Battisti, Anne
    Pucci, Olivia
    Minkovich, Leonid
    Duffin, James
    Fisher, Joseph
    FASEB JOURNAL, 2011, 25
  • [9] A novel approach for non-invasive measurement of blood haemoglobin
    Chaskar, U. M.
    Koli, S. R.
    Patil, S. L.
    INTERNATIONAL JOURNAL OF HEALTHCARE TECHNOLOGY AND MANAGEMENT, 2010, 11 (03) : 193 - 201
  • [10] Validation of a novel non-invasive ICP measurement technique
    Katila, Ari
    Zakelis, Rolandas
    Bartussis, Laimonas
    Ragauskas, Arminas
    Takala, Riikka
    Tenovuo, Olli
    Koskinen, Lars-Owe
    Malm, Jan
    Eklund, Anders
    BRAIN INJURY, 2014, 28 (5-6) : 854 - 854