Coordinated state-estimation method for air-conditioning loads to provide primary frequency regulation service

被引:16
|
作者
Li, Zihao [1 ]
Wu, Wenchuan [1 ]
Zhang, Boming [1 ]
机构
[1] Tsinghua Univ, Dept Elect Engn, Beijing, Peoples R China
基金
美国国家科学基金会;
关键词
air conditioning; frequency control; renewable energy sources; building management systems; centralised control; frequency response; power system state estimation; coordinated state-estimation method; air conditioning loads; primary frequency regulation service; large-scale renewable generation penetration; building thermal capacity; linear power- frequency characteristics; AC; bandwidth limitations; real-time centralised control method; two-level coordinated state-estimation method; coordination burden reduction; local controller; central coordinator; thermal parameters; heterogeneous parameters; rebound effect; THERMOSTATICALLY CONTROLLED LOADS; DEMAND;
D O I
10.1049/iet-gtd.2017.0176
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The penetration of large-scale renewable generation leads to a shortage of primary frequency regulation resources as well as increasing regulation demand. By exploiting the thermal capacity of buildings, the authors achieve linear power-frequency characteristics comparable to turbine droop control via clustering a number of air-conditioning units (ACs) to participate in primary frequency regulation without affecting indoor comfort. Due to the bandwidth limitations and latency in communication, the real-time centralised control method face great challenges. This study proposes a two-level coordinated state-estimation method to reduce the coordination burden, in which a central coordinator and local controller for each AC are involved. The central coordinator periodically gathers the working state of every AC and estimated thermal parameters individually, then broadcasts this identified model parameters - the coordination information - to each local controller. Resorting to a state-estimation method considering the coordinated information and local measurements, local controller determines whether to toggle the state of local AC to realise a fast frequency response. Simulation results show that the approach can effectively manage a large number of ACs with heterogeneous parameters to provide a primary frequency regulation service without inducing a rebound effect.
引用
收藏
页码:3381 / 3388
页数:8
相关论文
共 37 条
  • [1] Coordinated Control of Air-Conditioning Loads for System Frequency Regulation
    Jiang, Tingyu
    Ju, Ping
    Wang, Chong
    Li, Hongyu
    Liu, Jingzi
    [J]. IEEE TRANSACTIONS ON SMART GRID, 2021, 12 (01) : 548 - 560
  • [2] A hierarchical coordinated control strategy of air-conditioning loads for peak regulation service
    Wang, Wei
    Lin, Shunfu
    Wang, Lulu
    Mi, Yang
    Tan, Jin
    Qian, Liang
    Li, Dongdong
    Li, Fangxing
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2024, 18 (10) : 1980 - 1991
  • [3] Control of Residential Air-conditioning Loads to Provide Regulation Services under Uncertainties
    Lankeshwara, Gayan
    Sharma, Rahul
    Yan, Ruifeng
    Saha, Tapan K.
    [J]. 2021 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2021,
  • [4] Decentralized control strategy of air-conditioning loads for primary frequency regulation based on environment information
    Jiang, Baofeng
    Yang, Zheng
    Xiong, Wei
    Chen, Lingyu
    Wang, Pengyu
    Liao, Siyang
    [J]. FRONTIERS IN ENERGY RESEARCH, 2024, 11
  • [5] Coordinated Control Strategy of Air-conditioning Loads for Power System Balancing
    Liu, Meng
    Wei, Zhongkang
    Chu, Xiaodong
    Zhang, Wen
    [J]. 2014 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2014,
  • [6] Coordinated Control Method for DFIG-Based Wind Farm to Provide Primary Frequency Regulation Service
    Wang, Zhongguan
    Wu, Wenchuan
    [J]. 2020 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2020,
  • [7] Coordinated Control Method for DFIG-Based Wind Farm to Provide Primary Frequency Regulation Service
    Wang, Zhongguan
    Wu, Wenchuan
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2018, 33 (03) : 2644 - 2659
  • [8] A control strategy for air-conditioning loads participating in frequency regulation based on model predictive control
    Zhu, Guo-Xin
    Bao, Yu-Qing
    Yu, Qing-Quan
    [J]. SUSTAINABLE ENERGY GRIDS & NETWORKS, 2024, 38
  • [9] Distributed Control of Air-Conditioning Loads for Voltage Regulation in Active Distribution Network
    Wang, Dongxiao
    Meng, Ke
    Gao, Xiaodan
    Liang, Gaoqi
    Luo, Fengji
    Dong, Zhao Yang
    [J]. 2016 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PESGM), 2016,
  • [10] Modelling and control of central air-conditioning loads for power system emergency frequency control
    Liu, Meng
    Tian, Yuyang
    Cheng, Dingyi
    Zhang, Yan
    Ding, Lei
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2022, 16 (20) : 4054 - 4067