Non-invasive Image-Based Approach for Early Detection of Acute Renal Rejection

被引:0
|
作者
Khalifa, Fahmi [1 ]
El-Baz, Ayman [1 ]
Gimel'farb, Georgy [2 ]
Abu El-Ghar, Mohammed [3 ]
机构
[1] Univ Louisville, Dept Bioengn, Bioimaging Lab, Louisville, KY 40292 USA
[2] Univ Auckland, Dept Comp Sci, Auckland 1, New Zealand
[3] Univ Mansoura, Urology Nephrology Dept, Mansoura, Egypt
关键词
REGISTRATION;
D O I
暂无
中图分类号
TP31 [计算机软件];
学科分类号
081202 ; 0835 ;
摘要
A promising approach for the automatic classification of normal and acute rejection transplants from Dynamic Contrast Enhanced Magnetic Resonance Imaging (DCE-MRI) is proposed. The proposed approach consists of three main steps. The first step segments the kidney from the surrounding abdominal tissues by a level-set based deformable model with a speed function that accounts for a learned spatially variant statistical shape prior, 1(st)-order visual appearance descriptors of the contour interior and exterior (associated with the object and background, respectively), and a spatially invariant 2(nd)-order homogeneity descriptor. In the second step, to handle local object deformations due to kidney motion caused by patient breathing, we proposed a new nonrigid approach to align the object by solving Laplace's equation between closed equis-paced contours (iso-contours) of the reference and target objects. Finally, the perfusion curves that show the transportation of the contrast agent into the tissue are obtained from the segmented kidneys and used in the classification of normal and acute rejection transplants. Applications of the proposed approach yield promising results that would, in the near future, replace the use of current technologies such as nuclear imaging and ultrasonography, which are not specific enough to determine the type of kidney dysfunction.
引用
收藏
页码:10 / +
页数:3
相关论文
共 50 条
  • [1] Towards Non-invasive Image-Based Early Diagnosis of Autism
    Mostapha, M.
    Casanova, M. F.
    Gimel'farb, G.
    El-Baz, A.
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2015, PT II, 2015, 9350 : 160 - 168
  • [2] GlucoCEST MRI-based non-invasive detection of acute renal allograft rejection
    Kentrup, D.
    Busch, A.
    Pawelski, H.
    Schlatter, E.
    Hoerr, V.
    Reuter, S.
    [J]. ACTA PHYSIOLOGICA, 2015, 213 : 53 - 54
  • [3] NON-INVASIVE DETECTION OF ACUTE RENAL ALLOGRAFT REJECTION THROUGH GLUCOCEST MRI
    Kentrup, Dominik
    Busch, Annika
    Pawelski, Helga
    Schlatter, Eberhard
    Hoerr, Verena
    Reuter, Stefan
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2015, 30
  • [4] Detection of acute rejection: Validation of non-invasive diagnostic tests
    Ballester, M
    [J]. EUROPEAN HEART JOURNAL, 1997, 18 (06) : 885 - 886
  • [5] MiRNAs AS NON-INVASIVE BIOMARKER FOR ACUTE REJECTION OF RENAL ALLOGRAFT RECIPIENTS
    Soltaninejad, Ehsan
    Barabadi, Mehri
    Yekaninejad, Mir Saeed
    Amirzargar, Aliakbar
    [J]. TISSUE ANTIGENS, 2015, 85 (05): : 304 - 305
  • [6] Non-invasive early detection of acute transplant rejection via nanosensors of granzyme B activity
    Quoc D. Mac
    Dave V. Mathews
    Justin A. Kahla
    Claire M. Stoffers
    Olivia M. Delmas
    Brandon Alexander Holt
    Andrew B. Adams
    Gabriel A. Kwong
    [J]. Nature Biomedical Engineering, 2019, 3 : 281 - 291
  • [7] Non-invasive early detection of acute transplant rejection via nanosensors of granzyme B activity
    Mac, Quoc D.
    Mathews, Dave, V
    Kahla, Justin A.
    Stoffers, Claire M.
    Delmas, Olivia M.
    Holt, Brandon Alexander
    Adams, Andrew B.
    Kwong, Gabriel A.
    [J]. NATURE BIOMEDICAL ENGINEERING, 2019, 3 (04) : 281 - 291
  • [8] BIOMARKERS, A NON-INVASIVE APPROACH FOR DIAGNOSIS OF REJECTION IN RENAL TRANSPLANT RECIPIENTS
    Mostecki, Justin W.
    Zaslavskaia, Lioudmila
    Jiang, Ning
    Balazs, Ivan
    [J]. HUMAN IMMUNOLOGY, 2012, 73 : 95 - 95
  • [9] Non-invasive detection of acute renal allograft rejection by measurement of vascular endothelial growth factor in urine
    Peng, W.
    Chen, J.
    Jiang, Y.
    Shou, Z.
    Chen, Y.
    Wang, H.
    [J]. JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2007, 35 (04) : 442 - 449
  • [10] Accurate non-invasive image-based cytotoxicity assays for cultured cells
    Marques-Gallego, Patricia
    den Dulk, Hans
    Backendorf, Claude
    Brouwer, Jaap
    Reedijk, Jan
    Burke, Julian F.
    [J]. BMC BIOTECHNOLOGY, 2010, 10