Safety of dobutamine stress real-time myocardial contrast echocardiography

被引:88
|
作者
Tsutsui, JM [1 ]
Elhendy, A [1 ]
Xie, F [1 ]
O'Leary, EL [1 ]
McGrain, AC [1 ]
Porter, TR [1 ]
机构
[1] Univ Nebraska, Med Ctr, Dept Internal Med, Cardiol Sect, Omaha, NE 68198 USA
关键词
D O I
10.1016/j.jacc.2005.01.024
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The aim of this study was to determine the safety of dobutamine stress myocardial perfusion imaging (MPI) obtained by, real-time contrast echocardiography, (RTCE) and intravenous ultrasound contrast in a large cohort of patients with suspected coronary artery disease (CAD). BACKGROUND Despite the increasing number of studies showing the potential clinical utility of myocardial contrast perfusion imaging with commercially available contrast agents, the safety of this technique in a clinical setting has not been demonstrated. METHODS Over a four-year period, 1,486 patients underwent dobutamine stress RTCE with low mechanical index pulse sequence schemes after intravenous injections of commercially available contrast agents (35% Definity, Bristol Myers Squibb Medical Imaging Inc., North Billerica, Massachusetts; 65% Optison, GE-Amersham, Princeton, New Jersey). The hemodynamic and adverse effects of RTCE were compared with 1,012 patients who underwent conventional dobutamine stress echocardiography (DSE) without contrast. The feasibility of image analysis was defined as the ability to analyze MPI in at least two of the three standard segments in each left ventricular wall. RESULTS No myocardial infarction or death occurred during dobutamine stress. There was no difference in the incidence of nonsustained ventricular tachycardia, sustained ventricular tachycardia, or supraventricular tachycardia during dobutamine infusion between RTCE and DSE. Myocardial perfusion imaging was considered feasible for analysis in 94% of the walls at baseline and 95% at peak stress. The anterior, lateral, and posterior walls were the most common regions in which MPI was not feasible. Myocardial perfusion imaging with RTCE had a higher accuracy for detecting patients with angiographically significant CAD than the analysis of wall motion (84% vs. 66%, respectively; p < 0.001). CONCLUSIONS Dobutamine stress RTCE appears to be a safe and feasible technique for evaluating patients with known or suspected CAD.
引用
收藏
页码:1235 / 1242
页数:8
相关论文
共 50 条
  • [1] Real-time myocardial contrast dobutamine stress echocardiography in coronary stenosis
    Roberts, Elved B.
    Schafer, Frank
    Akhtar, Wahid
    Patel, Devan
    Evans, Tom R.
    Coghlan, J. G.
    Lipkin, David P.
    Davar, Joseph I.
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2006, 113 (01) : 19 - 24
  • [2] Safety of real-time myocardial contrast echocardiography in combination with dobutamine stress testing: experience from 5450 studies
    Aggeli, C.
    Giannopoulos, G.
    Roussakis, G.
    Christoforatou, E.
    Ntarladimas, I.
    Marinos, G.
    Kokkinakis, C.
    Stefanadis, C.
    [J]. EUROPEAN HEART JOURNAL, 2007, 28 : 276 - 276
  • [3] Dobutamine stress myocardial contrast echocardiography. Intermittent triggering in real-time era
    Hashem, MS
    El-Khateeb, H
    Shaaban, A
    Selim, ML
    Shaalan, A
    Mostafa, AH
    Feteih, Z
    [J]. EUROPEAN HEART JOURNAL, 2002, 23 : 300 - 300
  • [4] Ischemic cascade by real time myocardial contrast echocardiography during dobutamine stress echocardiography
    Coucello, J. A.
    Azevedo, J.
    Soares, L.
    Galvao, J.
    Silva, F.
    Custodio, H.
    Aleixo, A.
    [J]. EUROPEAN HEART JOURNAL, 2006, 27 : 514 - 514
  • [5] Comparison of adenosine stress and dobutamine stress by real-time myocardial contrast echocardiography in detecting myocardium ischemia in dogs
    Xing Yan-qiu
    Hou Bo-wen
    Zhang Yun
    Liu Xiang-qun
    Gao Hai-qing
    [J]. CHINESE MEDICAL JOURNAL, 2009, 122 (17) : 2002 - 2007
  • [7] Assessment of myocardial perfusion using real-time myocardial contrast echocardiography and dobutamine stress echocardiography in patients after percutaneous coronary intervention
    Shu, X. H.
    Pan, C. Z.
    Guo, S. Z.
    Ruan, W.
    Ge, J. B.
    Chen, H. Z.
    [J]. EUROPEAN HEART JOURNAL, 2006, 27 : 714 - 715
  • [8] Safety and feasibility of real time myocardial perfusion imaging with intravenous ultrasound contrast during dobutamine stress echocardiography
    Tsutsui, JM
    Xie, F
    Elhendy, A
    McGrain, AC
    Cory, B
    Garvin, R
    Porter, TR
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 303A - 304A
  • [9] Value of Low dose Dobutamine Stress Quantitative Real-Time Myocardial Contrast Echocardiography for Detection of Viable Myocardium
    Li, Dongye
    Hao, Ji
    Xia, Yong
    Qi, Chunmei
    Xu, Tongda
    Pan, Defeng
    Chen, Junhong
    Zhang, Hui
    Wang, Xiaoping
    Zhang, Yanbin
    [J]. CIRCULATION, 2010, 122 (02) : E108 - E108
  • [10] Real-time dobutamine stress myocardial perfusion echocardiography predicts outcome in the elderly
    Tsutsui, Jeane M.
    Xie, Feng
    Cloutier, David
    Kalvaitis, Saul
    Elhendy, Abdou
    Porter, Thomas R.
    [J]. EUROPEAN HEART JOURNAL, 2008, 29 (03) : 377 - 385