Physiological flow analysis in significant human coronary artery stenoses

被引:0
|
作者
Banerjee, RK
Back, LH
Back, MR
Cho, YI
机构
[1] Univ Cincinnati, Dept Mech Ind & Nucl Engn, Cincinnati, OH 45221 USA
[2] CALTECH, Jet Prop Lab, Pasadena, CA USA
[3] Univ S Florida, Coll Med, Div Vasc & Endovasc Surg, Tampa, FL USA
[4] Drexel Univ, Dept Mech Engn & Mech, Philadelphia, PA 19104 USA
关键词
D O I
暂无
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
To evaluate the local hemodynamics in flow limiting coronary lesions, computational hemodynamics was applied to a group of patients previously reported by Wilson et al. (1988) with representative pre-angioplasty stenosis geometry (minimal lesion size d(m)=0.95 mm; 68% mean diameter stenosis) and with measured values of coronary flow reserve (CFR) in the abnormal range (2.3+/-0.1). The computations were at mean flow rates ((Q) over tilde) of 50, 75 and 100 ml/min (the limit of our converged calculations). Computed mean pressure drops Delta(p) over tilde were similar to9 mmHg for basal flow (50 ml/min), similar to27 mmHg for elevated flow (100 ml/min) and increased to an extrapolated value of similar to34 mmHg for hyperemic flow (115 ml/min), which led to a distal mean coronary pressure (p) over tilde (rh) of similar to55 mmHg, a level known to cause ischemia in the subendocardium (Brown et al., 1984), and consistent with the occurrence of angina in the patients. Relatively high levels of wall shear stress were computed in the narrow throat region and ranged from about 600 to 1500 dyn/cm(2), with periodic (phase shifted) peak systolic values of about 3500 dyn/cm(2). In the distal vessel, the interaction between the separated shear layer wave, convected downstream by the core flow, and the wall shear layer flow, led to the formation of vortical flow cells along the distal vessel wall during the systolic phase where Reynolds numbers Re-e(t) were higher. During the phasic vortical mode observed at both basal and elevated mean flow rates, wide variations in distal wall shear stress occurred, distal transmural pressures were depressed below throat levels, and pressure recovery was larger farther along the distal vessel. Along the constriction (convergent) and throat segments of the lesion the pulsatile flow field was principally quasi-steady before flow separation occurred. The flow regimes were complex in the narrow mean flow Reynolds number range (R) over tildee(e)=100-230 and a frequency parameter of alpha(e)=2.25. The shear layer flow disturbances diminished in strength due to viscous damping along the distal vessel at these relatively low values of (R) over tildee(e), typical of flow through diseased epicardial coronary vessels. The distal hyperemic flow field was likely to be in an early stage of turbulent flow development during the peak systolic phase.
引用
收藏
页码:451 / 476
页数:26
相关论文
共 50 条
  • [1] Physiological flow simulation in residual human stenoses after coronary angioplasty
    Banerjee, RK
    Back, LH
    Back, MR
    Cho, YI
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2000, 122 (04): : 310 - 320
  • [2] Reduced coronary flow reserve in the coronary sinus is a predictor of hemodynamically significant stenoses of the left coronary artery territory
    Vrublevsky, AV
    Boshchenko, AA
    Karpov, RS
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 349A - 349A
  • [3] Subendocardial viability ratio as an index of impaired coronary flow reserve in hypertensives without significant coronary artery stenoses
    Tsiachris, D.
    Tsioufis, C.
    Syrseloudis, D.
    Roussos, D.
    Tatsis, I.
    Dimitriadis, K.
    Toutouzas, K.
    Tsiamis, E.
    Stefanadis, C.
    JOURNAL OF HUMAN HYPERTENSION, 2012, 26 (01) : 64 - 70
  • [4] Subendocardial viability ratio as an index of impaired coronary flow reserve in hypertensives without significant coronary artery stenoses
    D Tsiachris
    C Tsioufis
    D Syrseloudis
    D Roussos
    I Tatsis
    K Dimitriadis
    K Toutouzas
    E Tsiamis
    C Stefanadis
    Journal of Human Hypertension, 2012, 26 : 64 - 70
  • [5] The role of noninvasive imaging in assessing hemodynamically significant coronary artery stenoses
    Graham, John J.
    Dick, Alexander J.
    JOURNAL OF CARDIAC SURGERY, 2007, 22 (01) : 67 - 69
  • [6] Fractional Flow Reserve in Serial Coronary Artery Stenoses
    Kumbhani, Dharam J.
    Bhatt, Deepak L.
    JAMA CARDIOLOGY, 2016, 1 (03) : 359 - 360
  • [7] PROXIMAL CORONARY FLOW RESERVE DOES NOT REFLECT CORONARY FLOW RESERVE DISTAL TO SIGNIFICANT STENOSES
    HELLER, LI
    LEWIS, BS
    SILVER, KH
    DONOHUE, J
    WEINER, BH
    KERN, MJ
    KRAFT, PL
    BALCOM, SJ
    DECKELBAUM, LI
    CIRCULATION, 1994, 90 (04) : 227 - 227
  • [8] MULTICENTER EVALUATION OF DUAL SOURCE CT CORONARY ANGIOGRAPHY IN PATIENTS WITH INTERMEDIATE LIKELIHOOD OF CORONARY ARTERY STENOSES (MEDIC): ACCURACY FOR THE DETECTION OF INDIVIDUALS WITH SIGNIFICANT CORONARY ARTERY STENOSES
    Achenbach, Stephan
    Schuhbaeck, Annika
    Marwan, Mohamed
    Bathina, Ravi
    Ovrehus, Kristian
    Anders, Katharina
    Hoffmann, Udo
    Abbara, Suhny
    Aulbach, Peter
    Ropers, Dieter
    Pflederer, Tobias
    Becker, Christoph
    Berman, Daniel
    Hausleiter, Joerg
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E1337 - E1337
  • [9] Extremely high Agatston calcium score without significant coronary artery stenoses
    Moriel, Mady
    Bogot, Naama R.
    Wolak, Arik
    Hadas, Irith
    Weisz, Giora
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2015, 16 (03) : 346 - 346
  • [10] Ergonovine-induced alterations in coronary flow velocity preceding onset of occlusive spasm in patients without significant coronary artery stenoses
    Yamada, T
    Okamoto, M
    Sueda, T
    Hashimoto, M
    Matsuura, H
    Kajiyama, G