Total Arthroplasty of the Metatarsophalangeal Joint of the Hallux

被引:20
|
作者
Horisberger, Monika [1 ]
Haeni, David [1 ]
Henninger, Heath B. [2 ]
Valderrabano, Victor [3 ]
Barg, Alexej [4 ]
机构
[1] Univ Basel Hosp, Dept Orthopaed Surg, Spitalstr 21, CH-4031 Basel, Switzerland
[2] Univ Utah, Harold K Dunn Orthopaed Res Lab, Dept Orthopaed, Salt Lake City, UT USA
[3] Schmerzklin Basel, Dept Orthopaed & Traumatol, Basel, Switzerland
[4] Univ Utah, Dept Orthopaed, Salt Lake City, UT USA
关键词
prosthesis; metatarsophalangeal joint; hallux rigidus; REPLACEMENT ARTHROPLASTY; SILICONE PROSTHESIS; FUNCTIONAL OUTCOMES; ARTHRODESIS; RIGIDUS; PLATE; WEAR;
D O I
10.1177/1071100716637901
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The current gold standard in the treatment of severe hallux rigidus is arthrodesis of the first metatarsophalangeal (MTP-I) joint. We present the results of a new 3-component MTP-I prosthesis. We determined (1) the intraoperative and perioperative complications; (2) survivorship of prosthesis components and rate of secondary surgeries for any reason; (3) prosthetic component stability and radiographic alignment; (4) the degree of pain relief; and (5) the midterm functional outcomes including radiographic range of motion (ROM). Methods: From 2008 to 2010, we prospectively included 29 MTP-I prostheses in 25 patients. The average age of the patients was 63.1 years (range, 48-87 years). The average follow-up was 49.5 months (range, 36-62 months). We observed complications and reoperations. A visual analog scale for pain and the American Orthopaedic Foot & Ankle Society (AOFAS) forefoot score were obtained pre- and postoperation. Component stability and alignment were assessed using weight-bearing radiographs. Fluoroscopy was used to determine radiographic MTP-I ROM. Results: Seven (24.1%) patients underwent 1 or more secondary surgeries. Four cases (13.7%) eventually had a conversion to MTP-I arthrodesis. Two patients (3 cases) died from causes not related to the procedure. This left 22 feet in 19 patients for final follow-up. All but 3 remaining prostheses showed stable osteointegration and no migration, but MTP-I alignment showed high variability. The average pain score decreased from 5.9 (range, 3-9) to 1.2 (range, 0-5). The average AOFAS forefoot score increased from 55 (range, 0-80) to 83.5 (range, 58-95). Range of motion initially increased from 37.8 degrees (range, 0-60 degrees) to 88.6 degrees (range, 45-125 degrees) intraoperatively and decreased to 29.0 degrees (range, 11-52 degrees) at latest follow-up. Conclusion: Our data suggest that total arthroplasty of MTP-I leads to a high amount of revision surgeries, but the remaining patients had significant pain relief at midterm follow-up. However, we observed high variability regarding the prosthesis component alignment and poor range of motion. Level of Evidence: Level IV, prospective cohort study.
引用
收藏
页码:755 / 765
页数:11
相关论文
共 50 条
  • [1] RESULTS OF IMPLANT ARTHROPLASTY OF THE HALLUX METATARSOPHALANGEAL JOINT IN THE ARTHRITIC FOREFOOT
    CRACCHIOLO, A
    [J]. ARTHRITIS AND RHEUMATISM, 1980, 23 (06): : 664 - 664
  • [2] Titanium Arthroplasty Toe Fit Plus for the Hallux Metatarsophalangeal Joint
    Lange, J.
    Merk, H.
    Barz, T.
    Walther, C.
    Follak, N.
    [J]. ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2008, 146 (05): : 609 - 615
  • [3] Metatarsophalangeal Arthroplasty in Hallux Rigidus
    Bhimani, Rohan
    Labib, Sameh A.
    [J]. FOOT AND ANKLE CLINICS, 2024, 29 (03) : 495 - 505
  • [4] Total arthroplasty of the metatarsophalangeal joint of the hallux - an average 4 years prospective follow-up study
    Horisberger, Monika
    Haeni, David
    Barg, Alexej
    Valderrabano, Victor
    [J]. SWISS MEDICAL WEEKLY, 2014, 144 : 12S - 13S
  • [5] Tendon arthroplasty of the first metatarsophalangeal joint in hallux rigidus: Preliminary communication
    Barca, F
    [J]. FOOT & ANKLE INTERNATIONAL, 1997, 18 (04) : 222 - 228
  • [6] Use of titanium grommets in silicone implant arthroplasty of the hallux metatarsophalangeal joint
    Sebold, EJ
    Cracchiolo, A
    [J]. FOOT & ANKLE INTERNATIONAL, 1996, 17 (03) : 145 - 151
  • [7] Rolled Tendon Allograft Interposition Arthroplasty for Salvage Surgery of the Hallux Metatarsophalangeal Joint
    Thomas, Danielle
    Thordarson, David
    [J]. FOOT & ANKLE INTERNATIONAL, 2018, 39 (04) : 458 - 462
  • [8] Hallux Metatarsophalangeal (MTP) Joint Arthroscopy for Hallux Rigidus
    Hunt, Kenneth J.
    [J]. FOOT & ANKLE INTERNATIONAL, 2015, 36 (01) : 113 - 119
  • [9] Allograft Tendon Interposition Arthroplasty of the Hallux Metatarsophalangeal Joint: A Technique Guide and Literature Review
    Watson, Troy S.
    Panicco, Jordan
    Parekh, Amit
    [J]. FOOT & ANKLE INTERNATIONAL, 2019, 40 (01) : 113 - 119
  • [10] IRREDUCIBLE DORSAL DISLOCATION OF THE METATARSOPHALANGEAL JOINT OF THE HALLUX
    DECASAS, R
    MESA, F
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1990, 109 (03) : 173 - 174