Reference intervals for serum 1,5-anhydroglucitol of a population with normal glucose tolerance in Jiangsu Province

被引:7
|
作者
Chen, Cheng [1 ]
Wang, Xiaohang [1 ]
Tan, Yuanyuan [1 ]
Yang, Jiao [1 ]
Yuan, Yuexing [1 ]
Chen, Juan [1 ]
Guo, Haijian [2 ]
Wang, Bei [3 ]
Sun, Ziling [1 ]
Wang, Yao [1 ]
机构
[1] Southeast Univ, Med Sch, Zhongda Hosp, Inst Diabet,Dept Endocrinol, 87 Dingjiaqiao Rd, Nanjing 210009, Jiangsu, Peoples R China
[2] Jiangsu Prov Ctr Dis Control & Prevent, Dept Integrated Serv, Nanjing, Peoples R China
[3] Southeast Univ, Sch Publ Hlth, Minist Educ, Key Lab Environm Med Engn,Dept Epidemiol & Stat, Nanjing, Peoples R China
关键词
1; 5-anhydroglucitol; biomarker; reference interval; uric acid; URIC-ACID; MONITORING-SYSTEM; GLYCEMIC CONTROL; PLASMA; HEMOGLOBIN; EXCURSIONS; MARKER; ADULTS; ASSAY; RISK;
D O I
10.1111/1753-0407.13016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Serum 1,5-anhydroglucitol (1,5-AG) is a new glycemic marker which can reflect glucose fluctuation over 3 to 7 days and is now increasingly used to monitor glucose control and to screen for diabetes. However, 1,5-AG has not been widely used in China due to lack of epidemiological support. Our study aims to establish the reference intervals for a population with normal glucose tolerance in Jiangsu Province and to explore the determinants of these intervals. Method The study enrolled 646 healthy adults aged 20 to 70 years in Jiangsu Province in 2018 after oral glucose tolerance test. 1,5-AG, fasting and 2-hour glucose, UA, liver enzyme, serum lipid, creatinine, and glycosylated hemoglobin were measured. We calculated reference intervals using the parametric method and examined the relationship between 1,5-AG and influence factors. Results The average age of the participants was 50.5 +/- 9.0 years, and 69.5% of them were females. The reference intervals were 15.8 to 52.6 mu g/mL for males and 14.3 to 48.0 mu g/mL for females. Among females, the reference intervals were 13.9 to 45.3 and 14.6 to 49.6 mu g/mL for menopausal and postmenopausal females, respectively. Males showed higher 1,5-AG concentrations than females, and postmenopausal females had higher 1,5-AG than menopausal females. There was a positive correlation between uric acid and 1,5-AG in both genders. Positive correlation between 1,5-AG and age was only observed in females. Conclusion We established reference intervals for 1,5-AG in Jiangsu Province, and the level of 1,5-AG is affected by sex, uric acid, and age.
引用
收藏
页码:447 / 454
页数:8
相关论文
共 50 条
  • [1] Reference intervals for serum 1,5-anhydroglucitol in children, adolescents, adults, and pregnant women
    Welter, Marciane
    Boritza, Katia C.
    Anghebem-Oliveira, Mauren I.
    Henneberg, Railson
    Hauser, Aline B.
    Rego, Fabiane G. M.
    Picheth, Geraldo
    CLINICA CHIMICA ACTA, 2018, 486 : 54 - 58
  • [2] PLASMA 1,5-ANHYDROGLUCITOL IN SUBJECTS WITH VARIOUS GLUCOSE-TOLERANCE
    POPPSNIJDERS, C
    CROMME, PVM
    GEENEN, B
    VANDERVEEN, EA
    DIABETOLOGIA, 1986, 29 (08) : A583 - A583
  • [3] Evaluation of an assay for serum 1,5-anhydroglucitol (GlycoMark™) and determination of reference intervals on the Hitachi 917 analyzer
    Nowatzke, W
    Sarno, MJ
    Birch, NC
    Stickle, DF
    Eden, T
    Cole, TG
    CLINICA CHIMICA ACTA, 2004, 350 (1-2) : 201 - 209
  • [4] A decrease in serum 1,5-anhydroglucitol levels is associated with the presence of a first-degree family history of diabetes in a Chinese population with normal glucose tolerance
    Hu, X.
    He, X.
    Ma, X.
    Su, H.
    Ying, L.
    Peng, J.
    Wang, Y.
    Bao, Y.
    Zhou, J.
    Jia, W.
    DIABETIC MEDICINE, 2018, 35 (01) : 131 - 136
  • [5] Establishment of Community-Based Reference Intervals for Fructosamine, Glycated Albumin, and 1,5-Anhydroglucitol
    Selvin, Elizabeth
    Warren, Bethany
    He, Xintong
    Sacks, David B.
    Saenger, Amy K.
    CLINICAL CHEMISTRY, 2018, 64 (05) : 843 - 850
  • [6] Serum 1,5-anhydroglucitol is low in gastrectomized men
    Murai, Jun
    Koga, Masafumi
    Saito, Hiroshi
    Mukai, Mikio
    Kasayama, Soji
    ACTA DIABETOLOGICA, 2014, 51 (02) : 337 - 338
  • [7] Comparison of Two Assays for Serum 1,5-Anhydroglucitol
    Selvin, Elizabeth
    Rynders, Gregory P.
    Steffes, Michael W.
    CLINICA CHIMICA ACTA, 2011, 412 (9-10) : 793 - 795
  • [8] Serum 1,5-anhydroglucitol is low in gastrectomized men
    Jun Murai
    Masafumi Koga
    Hiroshi Saito
    Mikio Mukai
    Soji Kasayama
    Acta Diabetologica, 2014, 51 : 337 - 338
  • [9] Escherichia coli phosphorylates 1,5-anhydroglucitol and releases 1,5-anhydroglucitol 6-phosphate when glucose is absent in the medium
    Shiga, Y
    Kametani, S
    Mizuno, H
    Akanuma, H
    JOURNAL OF BIOCHEMISTRY, 1996, 119 (01): : 173 - 179
  • [10] Serum 1,5-anhydroglucitol when used with fasting plasma glucose improves the efficiency of diabetes screening in a Chinese population
    Lingwen Ying
    Xingxing He
    Xiaojing Ma
    Yun Shen
    Hang Su
    Jiahui Peng
    Yufei Wang
    Yuqian Bao
    Jian Zhou
    Weiping Jia
    Scientific Reports, 7