Measurement setups that characterize the impedance of suspensions of blood over the wide frequency range of 100 Hz to 100 MHz are presented in this paper. The performance of the two- and four-electrode techniques have been compared and evaluated. By applying a combination of the two measurement techniques the best result is achieved when taking into account the main nonidealities, such as electrode polarization impedance and parasitic capacitances. It has been found that the conventional three-element model for the impedance of blood can be used for frequencies up to 1 MHz. For frequencies exceeding 1 MHz, an extended model is introduced where a constant phase angle element is used for modeling the cell membrane and a capacitor C-liq is added for modeling the electrical capacitance of water in blood.
引用
收藏
页码:1247 / 1249
页数:3
相关论文
共 19 条
  • [1] Measurement of Attenuation of Attenuators in the Frequency Range 20 Hz –100 MHz
    Yu. D. Bolmusov
    P. A. Gorbachev
    [J]. Measurement Techniques, 2015, 57 : 1282 - 1286
  • [2] Measurement of Attenuation of Attenuators in the Frequency Range 20 Hz-100 MHz
    Bolmusov, Yu. D.
    Gorbachev, P. A.
    [J]. MEASUREMENT TECHNIQUES, 2015, 57 (11) : 1282 - 1286
  • [3] AC impedance investigation of conductivity of automotive lubricants using two- and four-electrode electrochemical cells
    Vadim F. Lvovich
    Matthew F. Smiechowski
    [J]. Journal of Applied Electrochemistry, 2009, 39 : 2439 - 2452
  • [4] AC impedance investigation of conductivity of automotive lubricants using two- and four-electrode electrochemical cells
    Lvovich, Vadim F.
    Smiechowski, Matthew F.
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 2009, 39 (12) : 2439 - 2452
  • [5] Electrochemical Impedance Spectroscopy of Ion-Selective Membranes: Artifacts in Two-, Three-, and Four-Electrode Measurements
    Anderson, Evan L.
    Buhlmann, Philippe
    [J]. ANALYTICAL CHEMISTRY, 2016, 88 (19) : 9738 - 9745
  • [6] Laboratory study of the electrical properties of Lutetian limestones in the 100 Hz to 10 MHz frequency range
    Souffache, Blaise
    Tabbagh, Alain
    [J]. NEAR SURFACE GEOPHYSICS, 2021, 19 (05) : 573 - 582
  • [7] IN-VITRO TISSUE CHARACTERIZATION AND MODELING USING ELECTRICAL-IMPEDANCE MEASUREMENTS IN THE 100 HZ-10 MHZ FREQUENCY-RANGE
    RIGAUD, B
    HAMZAOUI, L
    FRIKHA, MR
    CHAUVEAU, N
    MORUCCI, JP
    [J]. PHYSIOLOGICAL MEASUREMENT, 1995, 16 : A15 - A28
  • [8] VERIFICATION OF LCR METERS BY MEANS OF A 4TP 100 Ω LINEARITY TEST STANDARD OVER THE FREQUENCY RANGE 100 HZ TO 1 MHZ
    Nicolas, J.
    Van Theemsche, A.
    Awan, S. A.
    [J]. 2010 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS CPEM, 2010, : 374 - +
  • [9] Development of calibration techniques for ultrasonic hydrophone probes in the frequency range from 1 to 100 MHz
    Umchid, S.
    Gopinath, R.
    Srinivasan, K.
    Lewin, P. A.
    Daryoush, A. S.
    Bansal, L.
    El-Sherif, M.
    [J]. ULTRASONICS, 2009, 49 (03) : 306 - 311
  • [10] Two efficient methods for measuring hydrophone frequency response in the 100 kHz to 2 MHz range
    Harris, GR
    Maruvada, S
    Gammell, PM
    [J]. AMUM 2004: ADVANCED METROLOGY FOR ULTRASOUND IN MEDICINE 2004, 2004, 1 : 26 - 31