X-Ray Tomographic Study of Pore Volume Fraction in Samples of Polymer Composite Materials. Scanning and Reconstruction of Tomographic Data

被引:1
|
作者
Demidov, A. A. [1 ]
Krupnina, O. A. [1 ]
Mikhailova, N. A. [1 ]
Kosarina, E., I [1 ]
机构
[1] All Russian Sci Res Inst Aviat Mat, Moscow 105005, Russia
关键词
polymer composite material (PCM); pore volume fraction (PVF); X-ray computed tomography (XCT); subpixel scanning;
D O I
10.1134/S1061830921090047
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A description of the X-ray tomographic studies of samples made of polymer composite materials for the purpose of quantitative determination of the pore volume fraction is presented. The tomographic examination includes two stages: scanning and image reconstruction. A subpixel scanning method was applied at the first stage to increase the image resolution. The corrections provided in the software of the tomograph were applied when reconstructing the image. The results of evaluating the volume fraction of pores obtained by subpixel and cylindrical scanning showed their complete convergence.
引用
收藏
页码:779 / 786
页数:8
相关论文
共 50 条
  • [1] X-Ray Tomographic Study of Pore Volume Fraction in Samples of Polymer Composite Materials. Scanning and Reconstruction of Tomographic Data
    A. A. Demidov
    O. A. Krupnina
    N. A. Mikhailova
    E. I. Kosarina
    [J]. Russian Journal of Nondestructive Testing, 2021, 57 : 779 - 786
  • [2] X-ray tomographic reconstruction of macromolecular samples
    Brockhauser, Sandor
    Di Michiel, Marco
    McGeehan, John E.
    McCarthy, Andrew A.
    Ravelli, Raimond B. G.
    [J]. JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2008, 41 : 1057 - 1066
  • [3] A Theoretical Study of the Tomographic Reconstruction of Magnetosheath X-Ray Emissions
    Jorgensen, A. M.
    Xu, R.
    Sun, T.
    Huang, Y.
    Li, L.
    Dai, L.
    Wang, C.
    [J]. JOURNAL OF GEOPHYSICAL RESEARCH-SPACE PHYSICS, 2022, 127 (04)
  • [4] Software for X-ray fluorescence and scattering tomographic reconstruction
    Brunetti, A
    Golosio, B
    [J]. COMPUTER PHYSICS COMMUNICATIONS, 2001, 141 (03) : 412 - 425
  • [5] Prototyping X-ray tomographic reconstruction pipelines with FleXbox
    Kostenko, A.
    Palenstijn, W. J.
    Coban, S. B.
    Hendriksen, A. A.
    van Liere, R.
    Batenburg, K. J.
    [J]. SOFTWAREX, 2020, 11
  • [6] Materials characterization by x-ray topographic and tomographic imaging
    Green, RE
    Winter, JM
    Lipetzky, KG
    [J]. NONDESTRUCTIVE EVALUATION (NDE) AND MATERIAL PROPERTIES IV, 1999, : 21 - 28
  • [7] Angular-translational x-ray tomographic scanning approach for non-rotating samples
    Ozdiev, Ali
    Dolmatov, Dmitry
    Lazarev, Sergey
    [J]. NDT & E INTERNATIONAL, 2020, 113
  • [8] X-ray fluorescence tomographic system design and image reconstruction
    Cong, Wenxiang
    Shen, Haiou
    Cao, Guohua
    Liu, Hong
    Wang, Ge
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2013, 21 (01) : 1 - 8
  • [9] Computed tomographic reconstruction based on x-ray refraction contrast
    Maksimenko, A
    Ando, M
    Hiroshi, S
    Yuasa, T
    [J]. APPLIED PHYSICS LETTERS, 2005, 86 (12) : 1 - 3
  • [10] Tomographic image reconstruction using X-ray phase information
    Momose, A
    Takeda, T
    Itai, Y
    Hirano, K
    [J]. PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 : 674 - 684