Comparison of CHF measurements in R-134a cooled tubes and the water CHF look-up table

被引:43
|
作者
Pioro, IL [1 ]
Groeneveld, DC
Cheng, SC
Doerffer, S
Vasic, AZ
Antoshko, YV
机构
[1] Univ Ottawa, Dept Engn Mech, Ottawa, ON K1N 6N5, Canada
[2] AECL Res, Chalk River Labs, Chalk River, ON K0J 1J0, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
D O I
10.1016/S0017-9310(00)00093-4
中图分类号
O414.1 [热力学];
学科分类号
摘要
An exhaustive experimental study of the critical heat flux (CHF) in R-134a-cooled tubes has been recently completed. The objective of this study was to provide a consistent set of CHF data to be used as a reference for future separate effect studies. The investigated range of flow parameters in R-134a was: outlet pressure 0.96-2.39 MPa (equivalent to 6-14 MPa in water), mass flux 500-3000 kg m(-2) s(-1) (equivalent to 700-4300 kg m(-2) s(-1) in water), and critical quality -0.1 to +0.9. To extend the range of critical qualities, different heated lengths (0.45-2 m) and two-phase flow at inlet to the test section were used. Scaling laws were applied to convert the standard CHF look-up table from water to R-134a equivalent conditions. The comparison of the data with the water-based lookup table showed that for high mass fluxes (G = 1400-4300 kg m(-2) s(-1) in water equivalent), the look-up table provides an excellent CHF prediction for R-134a-cooled tubes. The differences were mainly noticeable for the limiting critical quality range and for low mass flux. A discussion of the observed limiting critical quality phenomenon is also included. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:73 / 88
页数:16
相关论文
共 50 条
  • [1] Comparison of CHF measurements in horizontal and vertical tubes cooled with R-134a
    Pioro, IL
    Groeneveld, DC
    Leung, LKH
    Doerffer, SS
    Cheng, SC
    Antoshko, YV
    Guo, Y
    Vasic, A
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2002, 45 (22) : 4435 - 4450
  • [2] The 2006 CHF look-up table
    Groeneveld, D. C.
    Shan, J. Q.
    Vasic, A. Z.
    Leung, L. K. H.
    Durmayaz, A.
    Yang, J.
    Cheng, S. C.
    Tanase, A.
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2007, 237 (15-17) : 1909 - 1922
  • [3] The 1995 CHF look-up table - Reply
    Groenveld, DC
    [J]. NUCLEAR ENGINEERING AND DESIGN, 1996, 163 (1-2) : 27 - 28
  • [4] The general post-CHF heat transfer prediction method for tubes on the base of the look-up table.
    Efanov, AD
    Ivashkevitch, AA
    Kirillov, PL
    Sergeev, VV
    Smogalev, IP
    Vinogradov, VN
    Groeneveld, DC
    Leung, LKH
    [J]. HEAT TRANSFER 1998, VOL 2: GENERAL PAPERS, 1998, : 237 - 241
  • [5] A look-up table for trans-critical heat transfer in water-cooled tubes
    Zahlan, H.
    Tavoularis, S.
    Groeneveld, D. C.
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2015, 285 : 109 - 125
  • [6] An independent assessment of Groeneveld et al.'s 1995 CHF look-up table
    Baek, WP
    Kim, HC
    Chang, SH
    [J]. NUCLEAR ENGINEERING AND DESIGN, 1997, 178 (03) : 331 - 337
  • [8] Investigation on the characteristic of CHF in various flow pattern regimes based on look-up table data
    Chandraker, D. K.
    Vijayan, P. K.
    Saha, D.
    Sinha, R. K.
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2008, 238 (01) : 170 - 177
  • [9] An empirical correlation for the entrainment fraction at the onset of annular flow based on 2006 CHF look-up table
    Jiao, Bo
    Yang, Dongyu
    Gan, Zhihua
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2017, 317 : 69 - 80
  • [10] Assessment of the look-up table using the tubular and bundle CHF data and modification of the bundle correction factor
    Chandraker, D. K.
    Vijayan, P. K.
    Saha, D.
    Sinha, R. K.
    [J]. KERNTECHNIK, 2006, 71 (04) : 192 - 202