Closed-loop multibody kinematic optimization coupled with double calibration improves scapular kinematic estimates in asymptomatic population

被引:5
|
作者
Blache, Y. [1 ]
Degot, M. [1 ]
Duprey, S. [2 ]
Begon, M. [3 ]
Rogowski, I. [1 ]
机构
[1] Univ Claude Bernard Lyon 1, Univ Lyon, Lab Interuniv Biol Motricite, EA 7424, F-69622 Villeurbanne, France
[2] Univ Gustave Eiffel, Univ Claude Bernard Lyon 1, Univ Lyon, IFSTTAR,LBMC,UMR T9406, F-69622 Lyon, France
[3] Univ Montreal, Ecole Kinesiol & Sci Act Phys, Montreal, PQ, Canada
关键词
Scapula; Scapulo-thoracic; Shoulder; Scapula locator; SHOULDER; MOTION; RELIABILITY; ORIENTATION; VALIDITY; JOINTS;
D O I
10.1016/j.jbiomech.2021.110653
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Non-invasive methods still need to better estimate scapular kinematics because of soft tissue artifact issue. This study aimed to develop and assess new procedures to estimate scapular kinematics by combining closed kinematic chain optimization and double calibration. Sixteen healthy volunteers performed static postures mimicking analytical and daily living movements. Scapulo-thoracic angles were computed either with a scapula locator (Ref), or with a closed-loop multibody kinematic optimization (Ell) or with double calibration involving linear (DClin), exponential (DCexp) or logarithmic (DClog) correction. Double calibration corrections enforced scapulo-thoracic angles to be the same than those measured with Ref at the end of the movement performed. DClin and DClog significantly (p < 0.01) reduced scapulothoracic misorientation for at least the second third of the movement with averaged improvement ranging from 9 degrees to 32 degrees. Moreover, for arm elevation in the sagittal plane, internal rotations and mimicking hair combing, the beneficial effect of DClin and DClog propagates up to half of the movement. To conclude, when a kinematic chain is required, coupling double calibration (using either linear or logarithmic correction), to a closed-loop multibody kinematic optimization is an efficient and fast method in regard with improvement in scapular kinematic estimates in healthy population.
引用
收藏
页数:6
相关论文
共 5 条
  • [1] Does double calibration coupled with a closed loop multibody kinematic optimization improve scapular kinematic estimates?
    Blache, Y.
    Degot, M.
    Begon, M.
    Duprey, S.
    Rogowski, I.
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2020, 23 : S35 - S37
  • [2] ANALYSIS OF A MULTIBODY ELASTODYNAMIC MODEL FOR CLOSED-LOOP KINEMATIC MECHANISMS
    Carbonari, Luca
    Brillarelli, Stefano
    Palpacelli, Matteo-Claudio
    Callegari, Massimo
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2019, VOL 9, 2019,
  • [3] CLOSED-LOOP KINEMATIC CALIBRATION OF THE RSI 6-DOF HAND CONTROLLER
    HOLLERBACH, JM
    LOKHORST, DM
    [J]. IEEE TRANSACTIONS ON ROBOTICS AND AUTOMATION, 1995, 11 (03): : 352 - 359
  • [4] Closed-Loop Kinematic Calibration of Robots Using a Six-Point Measuring Device
    Liu, Ying
    Zhuang, Zhenghao
    Li, Yuwen
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [5] A closed-loop kinematic approach to Self-Calibration of joint offset for multi-branched robots
    Zhao, Chuanlin
    Qian, Letian
    Wang, Shuhan
    Jia, Yuyi
    Luo, Xin
    [J]. MEASUREMENT, 2024, 238