An accelerated threshold-based back-projection algorithm for Compton camera image reconstruction

被引:5
|
作者
Mundy, Daniel W. [1 ]
Herman, Michael G. [1 ]
机构
[1] Mayo Clin, Dept Radiat Oncol, Rochester, MN 55905 USA
关键词
Compton camera; image reconstruction; back-projection; EMISSION COMPUTED-TOMOGRAPHY; COLLIMATED GAMMA-CAMERA; SCATTER CAMERA; SYSTEM;
D O I
10.1118/1.3519873
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Compton camera imaging (CCI) systems are currently under investigation for radiotherapy dose reconstruction and verification. The ability of such a system to provide real-time images during dose delivery will be limited by the computational speed of the image reconstruction algorithm. In this work, the authors present a fast and simple method by which to generate an initial back-projected image from acquired CCI data, suitable for use in a filtered back-projection algorithm or as a starting point for iterative reconstruction algorithms, and compare its performance to the current state of the art. Methods: Each detector event in a CCI system describes a conical surface that includes the true point of origin of the detected photon. Numerical image reconstruction algorithms require, as a first step, the back-projection of each of these conical surfaces into an image space. The algorithm presented here first generates a solution matrix for each slice of the image space by solving the intersection of the conical surface with the image plane. Each element of the solution matrix is proportional to the distance of the corresponding voxel from the true intersection curve. A threshold function was developed to extract those pixels sufficiently close to the true intersection to generate a binary intersection curve. This process is repeated for each image plane for each CCI detector event, resulting in a three-dimensional back-projection image. The performance of this algorithm was tested against a marching algorithm known for speed and accuracy. Results: The threshold-based algorithm was found to be approximately four times faster than the current state of the art with minimal deficit to image quality, arising from the fact that a generically applicable threshold function cannot provide perfect results in all situations. The algorithm fails to extract a complete intersection curve in image slices near the detector surface for detector event cones having axes nearly parallel to the image plane. This effect decreases the sum of the image, thereby also affecting the mean, standard deviation, and SNR of the image. All back-projected events associated with a simulated point source intersected the voxel containing the source and the FWHM of the back-projected image was similar to that obtained from the marching method. Conclusions: The slight deficit to image quality observed with the threshold-based back-projection algorithm described here is outweighed by the 75% reduction in computation time. The implementation of this method requires the development of an optimum threshold function, which determines the overall accuracy of the method. This makes the algorithm well-suited to applications involving the reconstruction of many large images, where the time invested in threshold development is offset by the decreased image reconstruction time. Implemented in a parallel-computing environment, the threshold-based algorithm has the potential to provide real-time dose verification for radiation therapy. (C) 2011 American Association of Physicists in Medicine. [ DOI: 10.1118/1.3519873]
引用
收藏
页码:15 / 22
页数:8
相关论文
共 50 条
  • [1] A Novel Kernel-Weighted Back-Projection Reconstruction Algorithm for Compton Camera Imaging
    Panthi, R.
    Mackin, D.
    Peterson, S.
    Maggi, P.
    Polf, J.
    Beddar, S.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E407 - E407
  • [2] Improvement of wavelet threshold filtered back-projection image reconstruction algorithm
    Ren, Zhong
    Liu, Guodong
    Huang, Zhen
    [J]. INTERNATIONAL SYMPOSIUM ON OPTOELECTRONIC TECHNOLOGY AND APPLICATION 2014: IMAGE PROCESSING AND PATTERN RECOGNITION, 2014, 9301
  • [3] A Filtered Back-Projection Algorithm for 4π Compton Camera Data
    Haefner, Andrew
    Gunter, Donald
    Barnowski, Ross
    Vetter, Kai
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (04) : 1911 - 1917
  • [4] Fast algorithm for list mode back-projection of Compton scatter camera data
    Wilderman, SJ
    Rogers, WL
    Knoll, GF
    Engdahl, JC
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 957 - 962
  • [5] Fast algorithm for list mode back-projection of Compton scatter camera data
    Wilderman, SJ
    Rogers, WL
    Knoll, GF
    Engdahl, JC
    [J]. 1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 391 - 395
  • [6] GPGPU Accelerated Fast Convolution Back-Projection for Radar Image Reconstruction
    周斌
    彭应宁
    叶春茂
    汤俊
    [J]. Tsinghua Science and Technology, 2011, 16 (03) : 256 - 263
  • [7] An adaptive filtered back-projection for photoacoustic image reconstruction
    Huang, He
    Bustamante, Gilbert
    Peterson, Ralph
    Ye, Jing Yong
    [J]. MEDICAL PHYSICS, 2015, 42 (05) : 2169 - 2178
  • [8] Study on an Improved Filtered Back-projection Image Reconstruction Algorithm Combined with Wavelet Denoising
    Ren, Zhong
    Liu, Guodong
    Huang, Zhen
    [J]. INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2013: INFRARED IMAGING AND APPLICATIONS, 2013, 8907
  • [9] Myocardial perfusion SPECT image reconstruction with an iteration algorithm vs filtered back-projection
    Meristoudis, G.
    Boutsali, S.
    Kokkinou-Paschou, A.
    Giougi, A.
    Giannakopoulos, V.
    Giourgouli, S.
    Roussis, C.
    Balomenos, A.
    Batsakis, C.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S455 - S455
  • [10] Image Retrieval Method Based on Back-Projection
    Arai, Kohei
    [J]. ADVANCES IN COMPUTER VISION, VOL 2, 2020, 944 : 689 - 698