Conversion from dose-length product to effective dose in computed tomography venography of the lower extremities

被引:3
|
作者
Inoue, Yusuke [1 ]
Yonekura, Yuka [1 ]
Nagahara, Kazunori [2 ]
Uehara, Ayuka [2 ]
Ikuma, Hideki [2 ]
机构
[1] Kitasato Univ, Dept Diagnost Radiol, Sch Med, Minami Ku, 1-15-1 Kitasato, Sagamihara, Kanagawa, Japan
[2] Kitasato Univ Hosp, Dept Radiol, Minami Ku, 1-15-1 Kitasato, Sagamihara, Kanagawa, Japan
关键词
computed tomography; radiation dose; effective dose; dose-length product; DEEP-VEIN THROMBOSIS; CT VENOGRAPHY; ITERATIVE RECONSTRUCTION; PULMONARY-EMBOLISM; RADIATION; MODULATION;
D O I
10.1088/1361-6498/ac49d6
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
For radiation dose assessment of computed tomography (CT), effective dose (ED) is often estimated by multiplying the dose-length product (DLP), provided automatically by the CT scanner, by a conversion factor. We investigated such conversion in CT venography of the lower extremities performed in conjunction with CT pulmonary angiography. The study subjects consisted of eight groups imaged using different scanners and different imaging conditions (five and three groups for the GE and Siemens scanners, respectively). Each group included ten men and ten women. The scan range was divided into four anatomical regions (trunk, proximal thigh, knee and distal leg), and DLP was calculated for each region (regional DLP). Regional DLP was multiplied by a conversion factor for the respective region, to convert it to ED. The sum of the ED values for the four regions was obtained as standard ED. Additionally, the sum of the four regional DLP values, an approximate of the scanner-derived DLP, was multiplied by the conversion factor for the trunk (0.015 mSv mGy cm(-1)), as a simplified method to obtain ED. When using the simplified method, ED was overestimated by 32.3%-70.2% and 56.5%-66.2% for the GE and Siemens scanners, respectively. The degree of overestimation was positively and closely correlated with the contribution of the middle and distal portions of the lower extremities to total radiation exposure. ED/DLP averaged within each group, corresponding to the conversion factor, was 0.0089-0.0114 and 0.0091-0.0096 mSv mGy cm(-1) for the GE and Siemens scanners, respectively. In CT venography of the lower extremities, ED is greatly overestimated by multiplying the scanner-derived DLP by the conversion factor for the trunk. The degree of overestimation varies widely depending on the imaging conditions. It is recommended to divide the scan range and calculate ED as a sum of regional ED values.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Cardiac-Specific Conversion Factors to Estimate Radiation Effective Dose From Dose-Length Product in Computed Tomography
    Trattner, Sigal
    Halliburton, Sandra
    Thompson, Carla M.
    Xu, Yanping
    Chelliah, Anjali
    Jambawalikar, Sachin R.
    Peng, Boyu
    Peters, M. Robert
    Jacobs, Jill E.
    Ghesani, Munir
    Jang, James J.
    Al-Khalidi, Hussein
    Einstein, Andrew J.
    JACC-CARDIOVASCULAR IMAGING, 2018, 11 (01) : 64 - 74
  • [2] Dose-Length Product to Effective Dose Conversion Factors for Common Computed Tomography Examinations Based on Canadian Clinical Experience
    Elbakri, Idris A.
    Kirkpatrick, Kin D. C.
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2013, 64 (01): : 15 - 17
  • [3] Effective Dose and Dose-Length Product in CT
    Shrimpton, Paul C.
    Wall, Barry F.
    RADIOLOGY, 2009, 250 (02) : 604 - U417
  • [4] BETTER ESTIMATING RADIATION EFFECTIVE DOSE FROM CARDIAC COMPUTED TOMOGRAPHY (CT): A COMPREHENSIVE EXAMINATION OF THE RELATIONSHIP BETWEEN EFFECTIVE DOSE AND DOSE-LENGTH PRODUCT
    Trattner, Sigal
    Halliburton, Sandra
    Thompson, Carla
    Chelliah, Anjali
    Xu, Yanping
    Jambawalikar, Sachin
    Peters, M. Robert
    Ghesani, Munir
    Jang, James
    Hoffmann, Udo
    Brenner, David J.
    Einstein, Andrew Jeffrey
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 1744 - 1744
  • [5] Converting dose-length product to effective dose at CT
    Huda, Walter
    Ogden, Kent M.
    Khorasani, Mohammad R.
    RADIOLOGY, 2008, 248 (03) : 995 - 1003
  • [6] Effective Dose and Dose-Length Product in CT Response
    Yoshizumi, Terry T.
    Hurwitz, Lynne M.
    Goodman, Philip C.
    RADIOLOGY, 2009, 250 (02)
  • [7] Effective Dose to Dose-Length Product Coefficients for Calculation of CT Effective Dose
    Opreanu, Razvan C.
    Samaraweera, Ranji
    Kepros, John P.
    RADIOLOGY, 2009, 252 (01) : 315 - 315
  • [8] ESTIMATING EFFECTIVE DOSE OF RADIATION FROM PEDIATRIC CARDIAC COMPUTED TOMOGRAPHY ANGIOGRAPHY USING A 64-SLICE SCANNER: NEW CONVERSION FACTORS RELATING DOSE-LENGTH PRODUCT TO EFFECTIVE DOSE
    Trattner, Sigal
    Chelliah, Anjali
    Ruzal-Shapiro, Carrie B.
    Xu, Yanping
    Jambawalikar, Sachin
    Amurao, Maxwell
    Hoffmann, Udo
    Brenner, David J.
    Einstein, Andrew Jeffrey
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 1743 - 1743
  • [9] Computing effective doses from dose-length product in CT - Response
    Yoshizumi, Terry T.
    Hurwitz, Lynne M.
    Goodman, Philip C.
    RADIOLOGY, 2008, 248 (01) : 321 - U420
  • [10] MONITORING DOSE-LENGTH PRODUCT IN COMPUTED TOMOGRAPHY OF THE CHEST CONSIDERING SEX AND BODY WEIGHT
    Inoue, Yusuke
    Nagahara, Kazunori
    Hayakawa, Naomichi
    Hanawa, Hironori
    Hata, Hirofumi
    RADIATION PROTECTION DOSIMETRY, 2016, 171 (03) : 375 - 381