A novel optimized hybrid fuzzy logic intelligent PID controller for an interconnected multi-area power system with physical constraints and boiler dynamics

被引:59
|
作者
Haroun, A. H. Gomaa [1 ,2 ]
Li, Yin-ya [1 ]
机构
[1] Nanjing Univ Sci & Technol, Sch Automat, Nanjing 210094, Jiangsu, Peoples R China
[2] Nyala Univ, Dept Elect & Elect Engn, Coll Engn Sci, South Darfur, Nyala, Sudan
基金
中国国家自然科学基金;
关键词
Load frequency control (LFC); Interconnected multi-area electrical power system; Particle swarm optimization (PSO); Intelligent PID controller; Fuzzy logic intelligent PID (FLiPID) controller; LOAD-FREQUENCY CONTROL; AUTOMATIC-GENERATION CONTROL; MAGNETIC ENERGY-STORAGE; GOVERNOR DEADBAND; DESIGN; PARAMETERS; ALGORITHM; AGC;
D O I
10.1016/j.isatra.2017.09.003
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In the fast developing world nowadays, load frequency control (LFC) is considered to be a most significant role for providing the power supply with good quality in the power system. To deliver a reliable power, LFC system requires highly competent and intelligent control technique. Hence, in this article, a novel hybrid fuzzy logic intelligent proportional-integral-derivative (FLiPID) controller has been proposed for LFC of interconnected multi-area power systems. A four-area interconnected thermal power system incorporated with physical constraints and boiler dynamics is considered and the adjustable parameters of the FLiPID controller are optimized using particle swarm optimization (PSO) scheme employing an integral square error (ISE) criterion. The proposed method has been established to enhance the power system performances as well as to reduce the oscillations of uncertainties due to variations in the system parameters and load perturbations. The supremacy of the suggested method is demonstrated by comparing the simulation results with some recently reported heuristic methods such as fuzzy logic proportional-integral (FLPI) and intelligent proportional-integral-derivative (PID) controllers for the same electrical power system. the investigations showed that the FLiPID controller provides a better dynamic performance and outperform compared to the other approaches in terms of the settling time, and minimum undershoots of the frequency as well as tie-line power flow deviations following a perturbation, in addition to perform appropriate settlement of integral absolute error (IAE). Finally, the sensitivity analysis of the plant is inspected by varying the system parameters and operating load conditions from their nominal values. It is observed that the suggested controller based optimization algorithm is robust and perform satisfactorily with the variations in operating load condition, system parameters and load pattern. (C) 2017 ISA. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:364 / 379
页数:16
相关论文
共 50 条
  • [1] A novel hybrid DEPS optimized fuzzy PI/PID controller for load frequency control of multi-area interconnected power systems
    Sahu, Rabindra Kumar
    Panda, Sidhartha
    Yegireddy, Narendra Kumar
    JOURNAL OF PROCESS CONTROL, 2014, 24 (10) : 1596 - 1608
  • [2] Design and analysis of fuzzy PID controller with derivative filter for AGC in multi-area interconnected power system
    Mohanty, Pradeep Kumar
    Sahu, Binod Kumar
    Pati, Tridipta Kumar
    Panda, Sidhartha
    Kar, Sanjeeb Kumar
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2016, 10 (15) : 3764 - 3776
  • [3] Ant lion optimized hybrid intelligent PID-based sliding mode controller for frequency regulation of interconnected multi-area power systems
    Haroun, Gomaa A. H.
    Li, Yin-Ya
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2020, 42 (09) : 1594 - 1617
  • [4] A novel optimized fractional-order hybrid fuzzy intelligent PID controller for interconnected realistic power systems
    Haroun, A. H. Gomaa
    Li Yin-Ya
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2019, 41 (11) : 3065 - 3080
  • [5] Load Frequency Control in Multi-Area Power System Based on Fuzzy Logic-PID Controller
    Kouba, Nour El Yakine
    Menaa, Mohamed
    Hasni, Mourad
    Boudour, Mohamed
    2015 IEEE INTERNATIONAL CONFERENCE ON SMART ENERGY GRID ENGINEERING (SEGE 2015), 2015,
  • [6] Ant Lion Optimized Fractional Order Fuzzy Pre-Compensated Intelligent Pid Controller for Frequency Stabilization of Interconnected Multi-Area Power Systems
    Haroun, A. H. Gomaa
    Li, Yin-Ya
    APPLIED SYSTEM INNOVATION, 2019, 2 (02) : 1 - 24
  • [7] A Novel Hybrid BFO-PS Optimized Fuzzy PID Controller for AGC of Interconnected Power System
    Xie, Pingping
    Zhu, Jizhong
    Hong, Chao
    Zhou, Baorong
    Liu, Yongjun
    Xuan, Peizheng
    Zou, Jin
    Zhao, Wenmeng
    2018 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2018,
  • [8] Gravitational Search Algorithm (GSA) Optimized Fuzzy-PID controller Design for Load frequency control of an interconnected multi-area power system
    Debnath, Manoj Kumar
    Mallick, Ranjan Kumar
    Das, Sadhana
    Aman, Aditya
    PROCEEDINGS OF IEEE INTERNATIONAL CONFERENCE ON CIRCUIT, POWER AND COMPUTING TECHNOLOGIES (ICCPCT 2016), 2016,
  • [9] Frequency regulation controller for multi-area interconnected power system
    Malek, Sajjad
    Khodabakhshian, Amin
    Hooshmand, Rahmat-Allah
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2024, 18 (17) : 2776 - 2792
  • [10] Fuzzy PID Controller Optimized by Improved Gravitational Search Algorithm for Load Frequency Control in Multi-area Power System
    Chen, Gonggui
    Qin, Feng
    Long, Hongyu
    Zeng, Xianjun
    Kang, Peng
    Zhang, Jinming
    IAENG International Journal of Computer Science, 2022, 49 (01) : 125 - 139