Surface Electromyography Characteristics for Motion Intention Recognition and Implementation Issues in Lower-limb Exoskeletons

被引:18
|
作者
Kyeong, Seulki [1 ]
Feng, Jirou [1 ]
Ryu, Jae Kwan [2 ]
Park, Jung Jae [2 ]
Lee, Kyeong Ha [2 ]
Kim, Jung [1 ]
机构
[1] Korea Adv Inst Sci & Technol KAIST, Dept Mech Engn, Daejeon 34141, South Korea
[2] LIG Nex 1, 333 Pangyo Ro, Seongnam Si, Gyeonggi Do, South Korea
关键词
Disturbance force; exoskeleton; surface electromyography (sEMG); walking environment; EMG; ORTHOSES; STRATEGY; FATIGUE;
D O I
10.1007/s12555-020-0934-3
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Recognizing the user's motion intentions is a crucial challenge to develop human augmented robotic devices due to safety and easiness of interactions. Among the possible sensorial modalities, surface electromyography (sEMG) signals have been tested to be a primary motion intention channel due to the inherent advantage of electromechanical delay and the muscle activation information. However, the lack of detailed sEMG characteristics as motion recognition has been difficult issues to develop safe and intuitive interactions with the robots. In this study, we evaluated the sEMG characteristics for their potential applicability to recognizing the motion intentions of humans. For the discrete motion intention recognition, the walking environments were classified using only sEMG signals by support vector machine (SVM) and linear discriminated analysis (LDA) models with accuracy of 79.1% and 76.3%. Due to the fact that it is crucial to identify an unexpected disturbance by the collision between the exoskeleton and surrounding environment in recognizing the user intention to guarantee the safety of the user, sEMG and torque sensors were used to classify user-intended interaction forces and disturbance forces in the event of collisions. A control algorithm was proposed that detects and compensates for collisions, and its performance showed that robust motion intention recognition and control of powered exoskeletons are possible. We investigated the effect of muscle fatigue caused by long-term walking with heavy load wearing an exoskeleton. The sEMG amplitude and frequency were analyzed for muscle fatigue due to single-joint (knee extensions) and multi-joint (walking) exercises, and muscle fatigue due to walking was prominent in the signal from the vastus medialis (VM). The characteristics of sEMG due to muscle fatigue should be seriously considered in continuous motion estimation.
引用
收藏
页码:1018 / 1028
页数:11
相关论文
共 50 条
  • [1] Surface Electromyography Characteristics for Motion Intention Recognition and Implementation Issues in Lower-limb Exoskeletons
    Seulki Kyeong
    Jirou Feng
    Jae Kwan Ryu
    Jung Jae Park
    Kyeong Ha Lee
    Jung Kim
    International Journal of Control, Automation and Systems, 2022, 20 : 1018 - 1028
  • [2] Human Lower Limb Motion Intention Recognition for Exoskeletons: A Review
    Li, Ling-Long
    Cao, Guang-Zhong
    Liang, Hong-Jie
    Zhang, Yue-Peng
    Cui, Fang
    IEEE SENSORS JOURNAL, 2023, 23 (24) : 30007 - 30036
  • [3] Lower limb motion recognition based on surface electromyography
    Tu, Juan
    Dai, ZunXiang
    Zhao, Xiang
    Huang, Zijuan
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 81
  • [4] Intention Recognition for Lower-Limb Exoskeleton
    Chen Q.-M.
    Huang R.
    Dianzi Keji Daxue Xuebao/Journal of the University of Electronic Science and Technology of China, 2018, 47 (03): : 330 - 336
  • [5] Lower Limb Motion Recognition with Improved SVM Based on Surface Electromyography
    Tu, Pengjia
    Li, Junhuai
    Wang, Huaijun
    SENSORS, 2024, 24 (10)
  • [6] Generation and control of adaptive gaits in lower-limb exoskeletons for motion assistance
    Sanz-Merodio, D.
    Cestari, M.
    Arevalo, J. C.
    Carrillo, X. A.
    Garcia, E.
    ADVANCED ROBOTICS, 2014, 28 (05) : 329 - 338
  • [7] An Adjustable Compliant Joint for Lower-Limb Exoskeletons
    Cestari, Manuel
    Sanz-Merodio, Daniel
    Carlos Arevalo, Juan
    Garcia, Elena
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2015, 20 (02) : 889 - 898
  • [8] Comparative Analysis of Environment Recognition Systems for Control of Lower-Limb Exoskeletons and Prostheses
    Laschowski, Brock
    McNally, William
    Wong, Alexander
    McPhee, John
    2020 8TH IEEE RAS/EMBS INTERNATIONAL CONFERENCE FOR BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB), 2020, : 581 - 586
  • [9] Gait parameter adaptation for lower-limb exoskeletons
    Sanz-Merodio, D.
    Cestari, M.
    Arevalo, J. C.
    Garcia, E.
    PROCEEDINGS IWBBIO 2013: INTERNATIONAL WORK-CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, 2013, : 667 - 675
  • [10] Mechatronic Exoskeletons for Lower-Limb Rehabilitation: An Innovative Review
    Huamanchahua, Deyby
    Taza-Aquino, Yerson
    Figueroa-Bados, Jhon
    Alanya-Villanueva, Jason
    Vargas-Martinez, Adriana
    Ramirez-Mendoza, Ricardo A.
    2021 IEEE INTERNATIONAL IOT, ELECTRONICS AND MECHATRONICS CONFERENCE (IEMTRONICS), 2021, : 926 - 933