Model tests on installation and extraction of suction caissons in dense sand

被引:27
|
作者
Zhang, Yukun [1 ]
Li, Dayong [2 ]
Gao, Yufeng [1 ]
机构
[1] Hohai Univ, Minist Educ Geomech & Embankment Engn, Key Lab, Nanjing, Jiangsu, Peoples R China
[2] Shandong Univ Sci & Technol, Coll Civil Engn & Architecture, Qingdao 266590, Peoples R China
基金
中国国家自然科学基金;
关键词
Extraction; model test; pullout capacity; suction caisson; suction-assisted installation; SHALLOW SKIRTED FOUNDATION; UPLIFT CAPACITY; MARINE SAND; COMPRESSION; TRANSIENT; CLAY;
D O I
10.1080/1064119X.2016.1259698
中图分类号
P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
A series of model tests were performed on steel- and Perspex-made suction caissons in saturated dense marine sand to explore installation and extraction behaviors. The extractions of the caisson were conducted by applying monotonic loading or by pumping water into the caisson. Responses of suction caissons to pullout rates, aspect ratios, and extraction manners were examined. Test results show that a cone-shaped subsidence region occurs around the suction caisson during the suction-assisted installation. The pullout bearing capacity of the suction caisson in sand is dominated by the loading rate and the loading manner. For the suction caisson subjected to monotonic loading, the maximum bearing capacity is reached at the pullout rate of about 20.0mm/s. The mobilized vertical displacement corresponding to the pullout capacity increases with increasing the pullout rate. The passive suction beneath the suction caisson lid reaches the maximum value when the pullout bearing capacity is mobilized. In addition, during the suction caisson extracted by pumping water into the caisson, the maximum pore water pressure in the caisson is obtained under the displacement of approximately 0.04 times the caisson diameter. The absolute values of the maximum pore water pressures for the suction caissons approximately equal those of the maximum vertical resistances at the monotonic pullout rate of 5 mm/s. When the vertical displacements of the suction caissons with the aspect ratio of 1.0 and 2.0 reach 0.92 and 1.77 times the caisson diameter, respectively, the seepage failure occurs around the caissons. Using a scaling method, the test results can be used to predict the time length required for the prototype suction caisson to be extracted from the seabed.
引用
收藏
页码:921 / 929
页数:9
相关论文
共 50 条
  • [1] Extraction of suction caissons in sand
    Lehane, B. M.
    Elkhatib, S.
    Terzaghi, S.
    GEOTECHNIQUE, 2014, 64 (09): : 735 - 739
  • [2] A full numerical model for the installation analysis of suction caissons in sand
    Harireche, Ouahid
    Naqash, Muhammad Tayyab
    Farooq, Qazi Umar
    OCEAN ENGINEERING, 2021, 234
  • [3] Suction caissons in dense sand, part I: installation, limiting capacity and drainage
    Bienen, B.
    Klinkvort, R. T.
    O'Loughlin, C. D.
    Zhu, F.
    Byrne, B. W.
    GEOTECHNIQUE, 2018, 68 (11): : 937 - 952
  • [4] A standard formulation for the installation of suction caissons in sand
    Alluqmani, Ayed Eid
    Naqash, Muhammad Tayyab
    Harireche, Ouahid
    JOURNAL OF OCEAN ENGINEERING AND SCIENCE, 2019, 4 (04) : 395 - 405
  • [5] Installation of suction caissons in sand with silt layers
    Tran, Manh N.
    Randolph, Mark F.
    Airey, David W.
    JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 2007, 133 (10) : 1183 - 1191
  • [6] Design procedures for installation of suction caissons in sand
    Houlsby, GT
    Byrne, BW
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-GEOTECHNICAL ENGINEERING, 2005, 158 (03) : 135 - 144
  • [7] Model tests on installation behavior of modified suction caissons in layered soil
    Zhang Yu-kun
    Qin Ting-hui
    Li Da-yong
    Wang Chong-chong
    ROCK AND SOIL MECHANICS, 2022, 43 (05) : 1317 - 1325
  • [8] Model tests on installation techniques of suction caissons in a soft clay seabed
    Guo, Zhen
    Wang, Lizhong
    Yuan, Feng
    Li, Lingling
    APPLIED OCEAN RESEARCH, 2012, 34 : 116 - 125
  • [9] The influence of the drainage regime on the installation and the response to vertical cyclic loading of suction caissons in dense sand
    Stapelfeldt, M.
    Bienen, B.
    Grabe, J.
    OCEAN ENGINEERING, 2020, 215
  • [10] Installation and lateral loading tests of suction caissons in silt
    Zhu, Bin
    Kong, De-qiong
    Chen, Ren-peng
    Kong, Ling-gang
    Chen, Yun-min
    CANADIAN GEOTECHNICAL JOURNAL, 2011, 48 (07) : 1070 - 1084