Validity and reliability of "Shriners Hospital for Children Upper Extremity Evaluation" in children with rheumatic diseases

被引:3
|
作者
Leblebici, Gokce [1 ,2 ]
Ovacik, Ugur [2 ,3 ]
Gungor, Feray [2 ,4 ]
Davids, Jon Robert [5 ]
Tarakci, Ela [4 ]
Kasapcopur, Ozgur [6 ]
机构
[1] Istanbul Medeniyet Univ, Fac Hlth Sci, Div Physiotherapy & Rehabil, D100 98 Kadikoy, TR-34000 Istanbul, Turkey
[2] Istanbul Univ Cerrahpasa, Inst Grad Studies, Dept Physiotherapy & Rehabil, Istanbul, Turkey
[3] Istanbul Aydin Univ, Vocat Sch Hlth Serv, Dept Med Serv & Tech, Physiotherapy Program, Istanbul, Turkey
[4] Istanbul Aydin Univ, Fac Hlth Sci, Div Physiotherapy & Rehabil, Istanbul, Turkey
[5] Shriners Hosp Children Northern Calif, Motion Anal Lab, Pediat Orthoped Surg, Sacramento, CA USA
[6] Istanbul Univ Cerrahpasa, Dept Pediat Rheumatol, Cerrahpasa Med Sch, Istanbul, Turkey
关键词
Function; Pediatrics; Reliability; Rheumatology; Upper extremity; Validity; HEALTH-ASSESSMENT QUESTIONNAIRE; VALIDATION; HAND; ARTHRITIS; ABILHAND; ABILITY;
D O I
10.1007/s10067-021-05866-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction/objectives The aim of this study was to investigate the validity and reliability of "Shriners Hospital for Children Upper Extremity Evaluation (SHUEE)" for children with rheumatic diseases. Methods The study was carried out after obtaining the necessary permissions and retrospectively registered. The psychometric properties evaluated were reliability and concurrent validity. Reliability was determined by intra- and inter-observer agreement. Concurrent validity was performed using the Jebsen Taylor Hand Function Test (JTHFT), Abilhand-Rheumatoid Arthritis (Abilhand-RA), and Children Health Assessment Questionnaire (CHAQ). The validity and reliability of the evaluation were determined after the retest 1 week later. Results Twenty children with rheumatic diseases were participated in to study. Intraclass coefficients ranged from 0.82 to 0.97 and the intraobserver reliability for SHUEE total and subscales were considered "excellent." Interobserver reliability was considered "excellent" for the SHUUE total score, spontaneous functional analysis and dynamic positional analysis, and "moderate" for grasp-release. A moderate negative correlation was determined between Spontaneous Functional Analysis and JTHFT (r = - 0.63; p = 0.003). Conclusion SHUEE is a valid and reliable evaluation for children with rheumatic diseases.
引用
下载
收藏
页码:5033 / 5040
页数:8
相关论文
共 50 条
  • [1] Validity and reliability of “Shriners Hospital for Children Upper Extremity Evaluation” in children with rheumatic diseases
    Gokce Leblebici
    Ugur Ovacik
    Feray Gungor
    Jon Robert Davids
    Ela Tarakci
    Ozgur Kasapcopur
    Clinical Rheumatology, 2021, 40 : 5033 - 5040
  • [2] Validation of the shriners hospital for children upper extremity evaluation(SHUEE) for children with hemiplegic cerebral palsy
    Davids, JR
    Peace, LC
    Wagner, LV
    Gidewall, MA
    Blackhurst, DW
    Roberson, WM
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (02): : 326 - 333
  • [3] Reliability and Validity of the Kinematic Dystonia Measure for Children With Upper Extremity Dystonia
    Kawamura, Anne
    Klejman, Sue
    Fehlings, Darcy
    JOURNAL OF CHILD NEUROLOGY, 2012, 27 (07) : 907 - 913
  • [4] Evaluation of the validity of the Prosthetic Upper Extremity Functional Index for children
    Wright, FV
    Hubbard, S
    Naumann, S
    Jutai, J
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2003, 84 (04): : 518 - 527
  • [5] An Assessment of the Applicability of Shriners Hospital Upper Extremity Evaluation as a Decision-making Tool and Outcome Measure in Upper Limb Cerebral Palsy in Indian Children
    Praveen Samuel Jose
    Veerappa Nagarathnam Radhakrishna
    Bibhudutta Sahoo
    Vrisha Madhuri
    Indian Journal of Orthopaedics, 2019, 53 : 15 - 19
  • [6] An assessment of the applicability of shriners hospital upper extremity evaluation as a decision-making tool and outcome measure in upper limb cerebral palsy in Indian children
    Jose, Praveen Samuel
    Radhakrishna, Veerappa Nagarathnam
    Sahoo, Bibhudutta
    Madhuri, Vrisha
    INDIAN JOURNAL OF ORTHOPAEDICS, 2019, 53 (01) : 15 - 19
  • [7] Validity and reliability of the Selective Control of the Upper Extremity Scale in children with upper motor neuron lesions
    Lieber, Jan
    Gartmann, Thomas
    Keller, Jeffrey W.
    van Hedel, Hubertus J. A.
    DISABILITY AND REHABILITATION, 2022, 44 (14) : 3694 - 3700
  • [8] Brazilian version of the Shriners Hospital Upper Extremity Evaluation (SHUEE): translation, cultural adaptation, and evaluation of psychometric properties
    Nicolini-Panisson, Renata D'agostini
    Tedesco, Ana Paula
    Davids, Jon Robert
    Wagner, Lisa Vorpagel
    Mattiello, Rita
    Fagundes Donadio, Marcio Vinicius
    REVISTA PAULISTA DE PEDIATRIA, 2020, 38
  • [9] Reliability and Validity of the Turkish Version of the Selective Control of the Upper Extremity Scale in Children with Cerebral Palsy
    Tuncdemir, Merve
    Karakaya, Jale
    Kerem-Gunel, Mintaze
    PHYSICAL & OCCUPATIONAL THERAPY IN PEDIATRICS, 2021, 42 (01) : 99 - 112
  • [10] EVALUATION AND MANAGEMENT OF PAIN IN CHILDREN WITH RHEUMATIC DISEASES
    VARNI, JW
    BERNSTEIN, BH
    RHEUMATIC DISEASE CLINICS OF NORTH AMERICA, 1991, 17 (04) : 985 - 1000