Characterization of a Perirectal Artifact in 18F-FDG PET/CT

被引:11
|
作者
Lodge, Martin A. [1 ]
Chaudhry, Muhammad A. [1 ]
Udall, Don N. [1 ]
Wahl, Richard L. [1 ,2 ]
机构
[1] Johns Hopkins Univ, Russell H Morgan Dept Radiol & Radiol Sci, Sch Med, Div Nucl Med, Baltimore, MD 21287 USA
[2] Johns Hopkins Univ, Sidney Kimmel Comprehens Canc Ctr Johns Hopkins, Sch Med, Baltimore, MD 21287 USA
关键词
PET/CT; artifact; attenuation correction; perirectal; bladder; RECTAL-CANCER; FLUORODEOXYGLUCOSE PET; ATTENUATION CORRECTION; NODE METASTASES; CT; DISSECTION; RECURRENCE; FREQUENCY; IMAGES;
D O I
10.2967/jnumed.110.079145
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Assessing tumor involvement in the rectal region can sometimes be complicated by what appears to be an artifact on F-18-FDG PET/CT images. This artifact manifests as a high-intensity region on the PET image, extending posterior to the bladder in the area around the rectum. The aim of this study was to describe this artifact, which-as far as we are aware-has not been previously reported, and to investigate its cause. Methods: One hundred F-18-FDG PET/CT studies (ordered-subsets expectation maximization reconstruction, CT attenuation correction) of patients with no known malignancy in the pelvis were retrospectively reviewed. Localized regions of apparently high uptake posterior to the bladder were considered an artifact when there was a discrepancy between attenuation-corrected (asymmetric appearance) and non-attenuation- corrected images (symmetric appearance). In addition, an experiment was performed using a body phantom containing 2 cylindric inserts simulating the bladder and a region of low-attenuation rectal gas. Attenuation-corrected images were reconstructed with different amounts of spatial misregistration intentionally introduced between the CT and PET images. Results: The artifact was observed in 15 of 100 patient studies and had a mean maximum standardized uptake value of 4.8 +/- 2.7. When fused with sequentially acquired CT images, the artifact always appeared to be in the perirectal region near the bladder and an area of rectal gas. The phantom study indicated this artifact was consistent with an attenuation-correction problem caused by misregistration between CT and PET. Movement of gas within the rectum can cause an air pocket to be present during the PET acquisition at a location where CT indicated soft tissue. The resulting localized overcorrection for attenuation at the margin of the rectum and the extremely high activity concentration in the nearby bladder contributed to the artifact. Conclusion: Movement of gas within the rectum between acquisition of CT and PET images can lead to an artifact in attenuation-corrected PET images in the perirectal region. An awareness of this artifact and reference to non-attenuation-corrected images will aid in the interpretation of F-18-FDG pelvis studies.
引用
收藏
页码:1501 / 1506
页数:6
相关论文
共 50 条
  • [1] Characterization of 'cold' vertebrae on 18F-FDG PET/CT
    Jaimini, Abhinav
    D'Souza, Maria M.
    Seniaray, Nikhil
    Sharma, Harshul
    Arbind, Arpana
    Sharma, Rajnish
    Mondal, Anupam
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2016, 37 (01) : 30 - 42
  • [2] Characterization of adrenal lesions with 18F-FDG PET/CT
    Slattery, JM
    Blake, MA
    Kalra, MK
    Fischman, AJ
    Mueller, PR
    Boland, GW
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) : 102 - 102
  • [3] Identification of a characteristic perirectal artifact in FDG PET/CT
    Lodge, Martin
    Udall, Don
    Chaudhry, Muhammad
    Wahl, Richard
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [4] Increased 18F-FDG uptake in degenerative disease of the spine:: Characterization with 18F-FDG PET/CT
    Rosen, Ron S.
    Fayad, Laura
    Wahl, Richard L.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2006, 47 (08) : 1274 - 1280
  • [5] 18F-FDG PET/CT in Angiosarcoma
    Kuo, W.
    Lin, C.
    Yen, T.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S476 - S476
  • [6] 18F-FDG PET and 18F-FDG PET/CT for Assessing Response to Therapy in Esophageal Cancer
    Krause, Bernd J.
    Herrmann, Ken
    Wieder, Hinrich
    zum Bueschenfelde, Christian Meyer
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2009, 50 : 89S - 96S
  • [7] The Performance of 18F-FDG PET and 18F-FDG PET/CT in Detection of Carcinoma of Unknown Primary
    Dong, M.
    Zhao, K.
    Zhao, J.
    Guan, Y.
    Liu, Z.
    Ruan, L.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S275 - S275
  • [8] 18F-FDG PET/MRI versus 18F-FDG PET/CT for the diagnosis of pituitary adenoma
    Wang, Hao
    Zhao, Xiaobin
    Zang, Jie
    Zhu, Zhaohui
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [9] Role of 18F-FDG PET/CT in the characterization of adrenal masses
    Ansquer, C.
    Taieb, D.
    [J]. MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2013, 37 (05): : 215 - 220
  • [10] Characterization of the normal adrenal gland with 18F-FDG PET/CT
    Bagheri, B
    Maurer, AH
    Cone, L
    Doss, M
    Adler, L
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2004, 45 (08) : 1340 - 1343