Energy Saving Quantitative Analysis of Passive, Active, and Renewable Technologies in Different Climate Zones

被引:2
|
作者
Kim, Chul-Ho [1 ]
Park, Min-Kyeong [2 ]
Kang, Won-Hee [2 ]
机构
[1] Korea Univ, Coll Engn, Res Inst Engn & Technol, 145 Anam Ro, Seoul 02841, South Korea
[2] Korea Univ, Coll Engn, Dept Architecture, 145 Anam Ro, Seoul 02841, South Korea
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 15期
关键词
high-performance buildings; passive systems; active systems; renewable energy systems; ASHRAE international climate zones; EnergyPlus; PERFORMANCE; BUILDINGS; EFFICIENCY; SYSTEMS; COMFORT; MODEL; HEAT;
D O I
10.3390/app11157115
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The purpose of this study was to provide a guideline for the selection of technologies suitable for ASHRAE international climate zones when designing high-performance buildings. In this study, high-performance technologies were grouped as passive, active, and renewable energy systems. Energy saving technologies comprising 15 cases were categorized into passive, active, and renewable energy systems. EnergyPlus v9.5.0 was used to analyze the contribution of each technology in reducing the primary energy consumption. The energy consumption of each system was analyzed in different climates (Incheon, New Delhi, Minneapolis, Berlin), and the detailed contributions to saving energy were evaluated. Even when the same technology is applied, the energy saving rate differs according to the climatic characteristics. Shading systems are passive systems that are more effective in hot regions. In addition, the variable air volume (VAV) system, combined VAV-energy recovery ventilation (ERV), and combined VAV-underfloor air distribution (UFAD) are active systems that can convert hot and humid outdoor temperatures to create comfortable indoor environments. In cold and cool regions, passive systems that prevent heat loss, such as high-R insulation walls and windows, are effective. Active systems that utilize outdoor air or ventilation include the combined VAV-economizer, the active chilled beam with dedicated outdoor air system (DOAS), and the combined VAV-ERV. For renewable energy systems, the ground source heat pump (GSHP) is more effective. Selecting energy saving technologies that are suitable for the surrounding environment, and selecting design strategies that are appropriate for a given climate, are very important for the design of high-performance buildings globally.
引用
收藏
页数:26
相关论文
共 50 条
  • [1] The integration of passive and active renewable energy technologies in cities
    Clarke, JA
    Johnstone, CM
    Macdonald, I
    [J]. REBUILD - THE EUROPEAN CITIES OF TOMORROW: SHAPING OUR EUROPEAN CITIES FOR THE 21ST CENTURY, 1998, : 294 - 297
  • [2] Passive Houses for different climate zones
    Schnieders, Juergen
    Feist, Wolfgang
    Rongen, Ludwig
    [J]. ENERGY AND BUILDINGS, 2015, 105 : 71 - 87
  • [3] The influence of building material, windows and insulators on energy saving in different climate zones in Iran
    P. Gohari
    [J]. International Journal of Energy and Water Resources, 2019, 3 (4) : 283 - 289
  • [4] Energy-saving potential of a radiant cooling system in different climate zones of India
    Khan, Yasin
    Bhandari, Mahabir
    Mathur, Jyotirmay
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2018, 24 (04) : 356 - 370
  • [5] Co-optimization of building energy systems with renewable generations combining active and passive energy-saving
    Wu, Zhiyue
    Shi, Xin
    Fang, Fang
    Wen, Gangcheng
    Mi, Yunjie
    [J]. APPLIED ENERGY, 2023, 351
  • [6] Application of Low Cost Active and Passive Energy Saving Technologies in an Ultra-low Energy Consumption Building
    Ma, Hongting
    Zhou, Weiye
    Lu, Xinyu
    Ding, Zequn
    Cao, Yang
    [J]. CUE 2015 - APPLIED ENERGY SYMPOSIUM AND SUMMIT 2015: LOW CARBON CITIES AND URBAN ENERGY SYSTEMS, 2016, 88 : 807 - 813
  • [7] The optimum thickness and energy saving potential of external wall insulation in different climate zones of China
    Zhu, Panyu
    Huckemann, Volker
    Fisch, M. Norbert
    [J]. 2011 INTERNATIONAL CONFERENCE ON GREEN BUILDINGS AND SUSTAINABLE CITIES, 2011, 21 : 608 - 616
  • [8] Assessment of practices and technologies of energy saving and renewable energy sources in hotels in Crete
    Zografakis, Nikolaos
    Gillas, Konstantinos
    Pollaki, Antrianna
    Profylienou, Maroulitsa
    Bounialetou, Fanouria
    Tsagarakis, Konstantinos P.
    [J]. RENEWABLE ENERGY, 2011, 36 (05) : 1323 - 1328
  • [9] Effects of climate change on outdoor meteorological parameters for building energy-saving design in the different climate zones of China
    Cao, Jingfu
    Li, Mingcai
    Wang, Min
    Xiong, Mingming
    Meng, Fanchao
    [J]. ENERGY AND BUILDINGS, 2017, 146 : 65 - 72
  • [10] Energy performance analysis of thermal insulating plaster in the different climate zones
    Kassim, Mohamed
    Aslani, Alireza
    Zahedi, Rahim
    [J]. THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 47