Tribological investigations of the wear couple alumina-CFRP for total hip replacement

被引:19
|
作者
Früh, HJ
Willmann, G
机构
[1] Sofamor Danek GMBH, Niederlassung Deggendorf, D-94469 Deggendorf, Germany
[2] CeramTec AG, D-73207 Plochingen, Germany
关键词
carbon fibre reinforced plastic (CFRP); alumina; hip replacement; tribology;
D O I
10.1016/S0142-9612(98)00006-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Wear debris is the main reason for aseptic loosening in total hip. Most troublesome is the wear of polyethylene cups. Ceramic femoral heads were introduced about 20 years ago. The combination ceramic-on-polyethylene reduces the wear rate and the loosening rate. But cups of polyethylene are still the weakest link in a hip prosthesis. Carbon fibre reinforced plastic (CFRP) was proposed as an alternative for polyethylene. Various test were performed to study the combination metal-on-CFRP, zirconia-on-CFRP, and alumina-an-CFRP. The simulator tests showed that the wear rate of alumina-on-CFRP is in the order of 1-3 mu m per year. Based on investigation of retrieved implants the wear rate is 6.3 mu m per year. Based on these results the combination alumina femoral heads (Biolox(R)-forte) and CFRP cups (Caproman(R)) could be approved for total hip replacement. (C) 1998 Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1145 / 1150
页数:6
相关论文
共 50 条
  • [1] Tribological investigations of the wear couple alumina-CFRP for total hip replacement
    Sofamor Danek GmbH, Niederlassung Deggendorf, Werftstr. 17, D-94469 Deggendorf, Germany
    不详
    Biomaterials, 13 (1145-1150):
  • [2] Clinical results of alumina-on-alumina couple in total hip replacement.
    Meunier, A
    Nizard, R
    Bizot, P
    Sedel, L
    ALTERNATIVE BEARING SURFACES IN TOTAL JOINT REPLACEMENT, 1998, 1346 : 213 - 234
  • [3] Influence of the wear-couple and patient activity on linear wear in total hip replacement
    Hendrich, Ch.
    Wollmerstedt, N.
    Goebel, S.
    Martell, J. M.
    BIOCERAMICS AND ALTERNATIVE BEARINGS IN JOINT ARTHROPLASTY, 2007, : 9 - 17
  • [4] Wear and friction behaviour of UHMWPE - Alumina combination for total hip replacement
    Chanda, A
    Mukhopadhyay, AK
    Basu, D
    Chatterjee, S
    CERAMICS INTERNATIONAL, 1997, 23 (05) : 437 - 447
  • [5] Tribological and material analyses of retrieved alumina and zirconia ceramic heads correlated with polyethylene wear after total hip replacement
    Kim, Y. -H.
    Kim, J. -S.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (06): : 731 - 737
  • [6] Effect of bovine serum constituents on the surface of the tribological pair alumina/alumina nanocomposites for total hip replacement
    Morillo, C.
    Sawae, Y.
    Murakami, T.
    TRIBOLOGY INTERNATIONAL, 2010, 43 (5-6) : 1158 - 1162
  • [7] Wear and friction behaviour of UHMWPE-alumina combination for total hip replacement
    Central Glass & Ceramic Research, Inst, Calcutta, India
    Journal of Engineering and Applied Science, 1997, 23 (05): : 437 - 447
  • [8] Alumina pairing in total hip replacement
    Nizard, R
    Sedel, L
    Hannouche, D
    Hamadouche, M
    Bizot, P
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (06): : 755 - 758
  • [9] Wear of alumina on alumina total hip prosthesis - Effect of lubricant on hip simulator test
    Ueno, M
    Amino, H
    Oonishi, H
    Clarke, IC
    Good, V
    BIOCERAMICS, 2000, 192-1 : 561 - 564
  • [10] Low wear and friction in alumina/alumina total hip joints - A hip simulator study
    Saikko, V
    Pfaff, HG
    ACTA ORTHOPAEDICA SCANDINAVICA, 1998, 69 (05): : 443 - 448