Clinically applicable labeling of mammalian and stem cells by combining; Superparamagnetic iron oxides and transfection agents

被引:529
|
作者
Frank, JA [1 ]
Miller, BR [1 ]
Arbab, AS [1 ]
Zywicke, HA [1 ]
Jordan, EK [1 ]
Lewis, BK [1 ]
Bryant, LH [1 ]
Bulte, JWM [1 ]
机构
[1] NIH, Expt Neuroimaging Sect, Lab Diagnost Radiol Res, Ctr Clin, Bethesda, MD 20892 USA
关键词
cell labeling; experimental study; iron; magnetic resonance (MR); experimental studies; stem cells;
D O I
10.1148/radiol.2281020638
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To label mammalian and stem cells by combining commercially available transfection agents (TAs) with superparamagnetic iron oxide (SPIO) magnetic resonance (MR) imaging contrast agents. MATERIALS AND METHODS Three TAs were incubated with ferumoxides and MION-46L in cell culture medium at various concentrations. Human mesenchymal i stem cells, mouse lymphocytes, rat oligodendrocyte progenitor CG-4 cells, and human cervical carcinoma cells were incubated 2-48 hours with 25 mug of iron per milliliter of combined TAs and SPIO. Cellular labeling was evaluated with T2 relaxometry, MR imaging of labeled cell suspensions, and Prussian blue staining for iron assessment. Proliferation and viability of mesenchymal stem cells and human cervical carcinoma cells labeled with a combination of TAs and ferumoxides were evaluated. RESULTS: When ferumoxides-TA or MION-46L-TA was used, intracytoplasmic particles stained with Prussian blue stain were detected for all cell lines with a labeling efficiency of nearly 100%. Limited or no uptake was observed for cells incubated i with ferumoxides or MION-46L alone. For TA-SPIO-labeled cells, MR images and relaxometry findings showed a. 50%-90% decrease in signal intensity and a more than 40-fold increase in T2s, Cell viability varied from 103.7% +/- 9 to 123.0% +/- 9 compared with control cell viability at 9 days, and cell proliferation was not affected by endosomal incorporation of SPIO nanoparticles. Iron concentrations varied with, ferumoxides-TA combinations and cells with a maximum of 30.1 pg +/- 3.7 of iron per cell for labeled mesenchymal stem cells. CONCLUSION: Magnetic labeling of mammalian cells with use of ferumoxides and TAs is possible and may enable cellular MR imaging and tracking in experimental and clinical settings. (C) RSNA, 2003.
引用
收藏
页码:480 / 487
页数:8
相关论文
共 50 条
  • [1] Clinically applicable labeling of mammalian and stem cells by combining superparamagnetic iron oxides and transfection agents (vol 228, pg 480, 2003)
    Frank, JA
    Miller, BR
    Arbab, AS
    Zywicke, HA
    Jordan, EK
    Lewis, BK
    Bryant, LH
    Bulte, JWM
    RADIOLOGY, 2003, 229 (02) : 610 - 610
  • [2] Magnetic intracellular labeling of mammalian cells by combining (FDA-approved) superparamagnetic iron oxide MR contrast agents and commonly used transfection agents
    Frank, JA
    Zywicke, H
    Jordan, EK
    Mitchell, J
    Lewis, BK
    Miller, B
    Bryant, LH
    Bulte, JWM
    ACADEMIC RADIOLOGY, 2002, 9 : S484 - S487
  • [3] Growth and differentiation of neural stem cells with superparamagnetic iron oxides labeling in vitro
    王爽
    谢鹏
    牟君
    赵裕光
    贾延劼
    吕发金
    罗天友
    方维东
    Journal of Medical Colleges of PLA, 2005, (05) : 273 - 275
  • [4] Carboxylated Superparamagnetic Iron Oxide Particles Label Cells Intracellularly Without Transfection Agents
    Volker Mailänder
    Myriam Ricarda Lorenz
    Verena Holzapfel
    Anna Musyanovych
    Karin Fuchs
    Markus Wiesneth
    Paul Walther
    Katharina Landfester
    Hubert Schrezenmeier
    Molecular Imaging and Biology, 2008, 10 : 138 - 146
  • [5] Carboxylated superparamagnetic iron oxide particles label cells intracellularly without transfection agents
    Mailaender, Volker
    Lorenz, Myriam Ricarda
    Holzapfel, Verena
    Musyanovych, Anna
    Fuchs, Karin
    Wiesneth, Markus
    Walther, Paul
    Landfester, Katharina
    Schrezenmeier, Hubert
    MOLECULAR IMAGING AND BIOLOGY, 2008, 10 (03) : 138 - 146
  • [6] Superparamagnetic iron oxide nanoparticles for direct labeling of stem cells and in vivo MRI tracking
    Kim, Saejeong J.
    Lewis, Bobbi
    Steiner, Mark-Steven
    Bissa, Ursula V.
    Dose, Christian
    Frank, Joseph A.
    CONTRAST MEDIA & MOLECULAR IMAGING, 2016, 11 (01) : 55 - 64
  • [7] Effect of Superparamagnetic Iron Oxide Nanoparticles-Labeling on Mouse Embryonic Stem Cells
    Parsa, Hamed
    Shamsasenjan, Karim
    Movassaghpour, Aliakbar
    Akbarzadeh, Parvin
    Tabrizi, Bahram Amoghli
    Dehdilani, Nima
    Loffinegad, Parisa
    Soleimanloo, Farzaneh
    CELL JOURNAL, 2015, 17 (02) : 221 - 230
  • [8] In Vitro Labeling of Human Umbilical Cord Mesenchymal Stem Cells With Superparamagnetic Iron Oxide Nanoparticles
    Hu, Sheng-Li
    Zhang, Jiu-Quan
    Hu, Xiang
    Hu, Rong
    Luo, Hai-Shui
    Li, Fei
    Xia, Yong-Zhi
    Li, Jiang-Tao
    Lin, Jiang-Kai
    Zhu, Gang
    Feng, Hua
    JOURNAL OF CELLULAR BIOCHEMISTRY, 2009, 108 (02) : 529 - 535
  • [9] Transferrin receptor upregulation:: In vitro labeling of rat mesenchymal stem cells with superparamagnetic iron oxide
    Schaefer, Richard
    Kehlbach, Rainer
    Wiskirchen, Jakub
    Bantleon, Ruediger
    Pintaske, Joerg
    Brehm, Bernhard R.
    Gerber, Annika
    Wolburg, Hartwig
    Claussen, Claus D.
    Northoff, Hinnak
    RADIOLOGY, 2007, 244 (02) : 514 - 523
  • [10] EFFECTS OF SUPERPARAMAGNETIC IRON OXIDE LABELING ON CHONDROCYTE DIFFERENTIATION OF MESENCHYMAL STEM CELLS IN COLLAGEN SPONGE
    Henrionnet, C.
    Roeder, E.
    Goebel, J.
    Galois, L.
    Bensoussan, D.
    Felblinger, J.
    Magdalou, J.
    Beuf, O.
    Gillet, P.
    Pinzano, A.
    OSTEOARTHRITIS AND CARTILAGE, 2010, 18 : S83 - S83