Analysis of violet-excited fluorochromes by flow cytometry using a violet laser diode

被引:20
|
作者
Telford, WG
Hawley, TS
Hawley, RG
机构
[1] NCI, Expt Transplantat & Immunol Branch, Ctr Canc Res, NIH, Bethesda, MD 20892 USA
[2] Amer Red Cross, Holland Lab, Rockville, MD USA
关键词
violet laser diode; Cascade Blue; Pacific Blue; cyan fluorescent protein; 2-(5 '-chloro-2 '-phosphoryloxyphenyl)-6-chloro-4-(3H)-quinazoline;
D O I
10.1002/cyto.a.10046
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Low power violet laser diodes (VLDs) have been evaluated as potential replacements for water-cooled argon-ion and krypton-ion ultraviolet and violet lasers for DNA content analysis using the Hoechst dyes and 4,6diamidino-2-phenylindole (Shapiro HMN, Perlmutter NG: Cytometry 44:133-136, 2001). In this study, we used a VLD to excite a variety of violet-excited fluorescent molecules important in biomedical analysis, including the fluorochromes Cascade Blue and Pacific Blue, the expressible fluorescent protein cyan fluorescent protein (CFP), and the fluorogenic alkaline phosphatase (AP) substrate 2-(5'-chloro-2'-phosphoryloxyphenyl)-6-chloro-4-(3H)-quinazoline (ELF-97; for endogenous AP detection and cell surface labeling with AP-conjugated antibodies). Methods: Comparisons were made between VLD excitation and a krypton-ion laser emitting at 407 nm (both at higher power levels and with the beam attenuated at levels approximating the VLD) on the same FACSVantage SE stream-in-air flow cytometer. We evaluated a Power Technology 408-nm VLD (30 mW) equipped with circularization optics (18 mW maximum output, set to 15 mW) and a Coherent I-302C krypton-ion laser emitting at power levels ranging from 15 to 75 mW. Results: Cascade Blue, Pacific Blue, and CFP showed comparable signal-to-noise ratios and levels of sensitivity with VLD excitation versus the krypton-ion laser at high and VLD-matched power outputs. Multicolor fluorescent protein analysis with 488-nm excitation of green fluorescent protein and DsRed and VLD excitation of CFP was therefore feasible and was demonstrated. Similar levels of excitation efficiency between krypton-ion and VLD sources also were observed for ELF-97 detection. Conclusions: These evaluations confirmed that VLDs may be cost- and maintenance-effective replacements for water-cooled gas lasers for applications requiring violet excitation in addition to DNA binding dyes. Published 2003 Wiley-Liss, Inc.
引用
收藏
页码:48 / 55
页数:8
相关论文
共 50 条
  • [1] Analysis of violet-excited fluorochromes by flow cytometry using a violet diode laser
    Telford, W
    Hawley, TS
    Hawley, RG
    CYTOMETRY, 2002, : 123 - 123
  • [2] VIOBLUE™: A NOVEL VIOLET-EXCITED DYE FOR MULTICOLOR FLOW CYTOMETRY
    Herber, M.
    Weber-Lohmann, S.
    Buescher, M.
    Krauthaeuser, S.
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2008, 74B (06) : 381 - 382
  • [3] Pairs of violet-light-excited fluorochromes for flow cytometric analysis
    Anderson, MT
    Baumgarth, N
    Haugland, RP
    Gerstein, RM
    Tjioe, T
    Herzenberg, LA
    Herzenberg, LA
    CYTOMETRY, 1998, 33 (04): : 435 - 444
  • [4] Use of pacific Orange® dye with Qdot® nanocrystals and other violet-excited dyes in polychromatic flow cytometry.
    Buller, Gayle M.
    Liu, JiXiang
    Yue, Stephen
    Bradford, Jolene A.
    Godffrey, William L.
    BLOOD, 2006, 108 (11) : 52B - 53B
  • [5] Violet laser diodes in flow cytometry: An update
    Telford, William
    Kapoor, Veena
    Jackson, James
    Burgess, Walter
    Buller, Gayle
    Hawley, Teresa
    Hawley, Robert
    CYTOMETRY PART A, 2006, 69A (11) : 1153 - 1160
  • [6] FRET causing misleading signal from fluorescein excited by the violet laser in flow cytometry
    Waeckel, Louis
    Khenine, Hana
    Berger, Anne-Emmanuelle
    Lambert, Claude
    CYTOMETRY PART A, 2023, 103 (09) : 732 - 735
  • [7] Side population analysis using a violet-excited cell-permeable DNA binding dye
    Telford, William G.
    Bradford, Jolene
    Godfrey, William
    Robey, Robert W.
    Bates, Susan E.
    STEM CELLS, 2007, 25 (04) : 1029 - 1036
  • [8] Analysis of UV-excited fluorochromes by flow cytometry using near-ultraviolet laser diodes
    Telford, WG
    CYTOMETRY PART A, 2004, 59A (01) : 41 - 41
  • [9] Photoporation and cell transfection using a violet diode laser
    Paterson, L
    Agate, B
    Comrie, M
    Ferguson, R
    Lake, TK
    Morris, JE
    Carruthers, AE
    Brown, CTA
    Sibbett, W
    Bryant, PE
    Gunn-Moore, F
    Riches, AC
    Dholakia, K
    OPTICS EXPRESS, 2005, 13 (02): : 595 - 600
  • [10] A Simple and Effective Method for Differentiating GFP and YFP by Flow Cytometry using the Violet Laser
    Marcus, Assaf
    Raulet, David H.
    CYTOMETRY PART A, 2013, 83 (11) : 973 - 974