摘要
Inductor filter is widely used in grid-tied inverters. If an inverter with inductor filter operates in weak grid condition, voltage measurement error may exist due to the voltage sensor delay and the voltage drop on grid impedance. This can further lead to errors in the phase lock loop (PLL) and even system instability. In this paper, we analyze the voltage measurement error in weak grid condition in detail. All the essential elements in the measurement chain are considered. Analysis shows large DC offset and harmonic components may exist in the sampled voltage. To improve the PLL performance in weak grid condition, a PLL with extra DC offset and 2nd order harmonic rejection capability is presented. Further, the inverter current controller is designed considering grid impedance and grid harmonics. Experiments are performed to verify the presented method.
引用
收藏
页码:1103 / 1108
页数:6
相关论文
共 50 条
  • [1] Prescriptive Grid-Tied Inverter Control
    Lopez-Sarabia, Jorge L.
    Mayo-Maldonado, Jonathan C.
    Escobar, Gerardo
    Stone, David A.
    del Puerto-Flores, Dunstano
    Li, Yunwei
    [J]. IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2023, 11 (05) : 4818 - 4830
  • [2] Adaptive Virtual Impedance of Grid-Tied Inverters to Enhance the Stability in a Weak Grid
    Yan Du
    Qingqing Sun
    Xiangzhen Yang
    Linbo Cui
    Jian Zhang
    Fei Wang
    [J]. Journal of Electrical Engineering & Technology, 2019, 14 : 1235 - 1246
  • [3] Adaptive Virtual Impedance of Grid-Tied Inverters to Enhance the Stability in a Weak Grid
    Du, Yan
    Sun, Qingqing
    Yang, Xiangzhen
    Cu, Linbo
    Zhang, Jian
    Wang, Fei
    [J]. JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2019, 14 (03) : 1235 - 1246
  • [4] Performance Improvement of H8 Transformerless Grid-Tied Inverter Using Model Predictive Control Considering a Weak Grid
    Zaid, Sherif A.
    Albalawi, Hani
    AbdelMeguid, Hossam
    Alhmiedat, Tareq A.
    Bakeer, Abualkasim
    [J]. PROCESSES, 2022, 10 (07)
  • [5] Analysis and Design of Grid-Tied Inverter With LCL Filter
    Bierhoff, Michael
    Soliman, Ramy
    Espinoza C, Jose R.
    [J]. IEEE OPEN JOURNAL OF POWER ELECTRONICS, 2020, 1 : 161 - 169
  • [6] Analysis and design of grid-tied inverter with LCL filter
    Stralsund University of Applied Sciences, Stralsund
    18435, Germany
    不详
    53-C, Chile
    [J]. IEEE Open J. Power Electron., (161-169):
  • [7] Current Control Optimization for Grid-tied Inverters with Grid Impedance Estimation
    Shen, Guoqiao
    Zhang, Jun
    Li, Xiao
    Du, Chengrui
    Xu, Dehong
    [J]. 2010 TWENTY-FIFTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2010, : 861 - 866
  • [8] Impedance Modeling and Stability Analysis of Grid-tied Universal Droop Control Inverter
    Amin, Mohammad
    Zhong, Qing-Chang
    [J]. 2019 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2019, : 5569 - 5575
  • [9] On the Grid-Tied Inverter Power Limitation
    Tsai, Terng-Wei
    Chen, Yaow-Ming
    [J]. 2018 IEEE INTERNATIONAL POWER ELECTRONICS AND APPLICATION CONFERENCE AND EXPOSITION (PEAC), 2018, : 1847 - 1850
  • [10] An LCL-LC Power Filter for Grid-Tied Inverter
    Zhang, Xing
    Zhu, Hong
    Li, Fei
    Liu, Fang
    Liu, Chun
    Li, Benxuan
    [J]. 2013 IEEE INTERNATIONAL CONFERENCE OF IEEE REGION 10 (TENCON), 2013,