Tracking three dimensional ultrasound with immunity from ferro-magnetic interference

被引:0
|
作者
Sheehan, FH [1 ]
Schneider, M [1 ]
Bolson, EL [1 ]
Webster, B [1 ]
机构
[1] Univ Washington, Cardiovasc Res & Training Ctr, Seattle, WA 98195 USA
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Magnetic field tracking devices offer many advantages over other methods for tracking transducer location and orientation during ultrasound image acquisition. The disadvantage is sensitivity to ferromagnetic interference. We evaluated an "immune" tracking device that uses a flat plate magnetic field transmitter to shield the tracking volume from interference from the hospital bed. When we compared its accuracy with that of Ascension Technology, Inc.'s Flock of Birds(TM), we found that the immune device performed as well on a hospital bed as the Bird in a control environment. We conclude that the flat plate transmitter enables three-dimensional ultrasound by the freehand scanning approach in a clinical environment.
引用
收藏
页码:192 / 198
页数:7
相关论文
共 50 条
  • [1] Dynamical analysis and the soliton solutions of (2+1)-dimensional Heisenberg ferro-magnetic spin chains model with beta fractional derivative
    Luo, Jie
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [2] Ultrasound three-dimensional velocity measurements by feature tracking
    Bashford, GR
    vonRamm, OT
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1996, 43 (03) : 376 - 384
  • [3] Development of three-dimensional endoscopic ultrasound system with optical tracking
    Koizumi, N
    Sumiyama, K
    Suzuki, N
    Hattori, A
    Tajiri, H
    Uchiyama, A
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION-MICCAI 2002, PT 1, 2002, 2488 : 60 - 65
  • [4] Three-dimensional magnetic resonance myocardial motion tracking from a single image plane
    Abd-Elmoniem, Khaled Z.
    Osman, Nael F.
    Prince, Jerry L.
    Stuber, Matthias
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (01) : 92 - 102
  • [5] Three dimensional tracking with ultrasound for augmented reality applications in skull base surgery
    Alusi, G
    Tan, AC
    Linney, AD
    Raoof, K
    Wright, A
    CVRMED-MRCAS'97: FIRST JOINT CONFERENCE - COMPUTER VISION, VIRTUAL REALITY AND ROBOTICS IN MEDICINE AND MEDICAL ROBOTICS AND COMPUTER-ASSISTED SURGERY, 1997, 1205 : 511 - 517
  • [6] GPU based real-time instrument tracking with three dimensional ultrasound
    Novotny, Paul M.
    Stoll, Jeffrey A.
    Vasilyev, Nikolay V.
    del Nido, Pedro J.
    Dupont, Pierre E.
    Howe, Robert D.
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2006, PT 1, 2006, 4190 : 58 - 65
  • [7] Magnetic sensor data acquisition for three-dimensional ultrasound of the orbit
    Delcker, A
    Martin, T
    Tegeler, C
    EYE, 1998, 12 (4) : 725 - 728
  • [8] Magnetic sensor data acquisition for three-dimensional ultrasound of the orbit
    A Delcker
    T Martin
    C Tegeler
    Eye, 1998, 12 : 725 - 728
  • [9] GPU based real-time instrument tracking with three-dimensional ultrasound
    Novotny, Paul M.
    Stoll, Jeff A.
    Vasilyev, Nikolay V.
    del Nido, Pedro J.
    Dupont, Pierre E.
    Zickler, Todd E.
    Howe, Robert D.
    MEDICAL IMAGE ANALYSIS, 2007, 11 (05) : 458 - 464
  • [10] Statistical analysis of decorrelation-based transducer tracking for three-dimensional ultrasound
    Smith, W
    Fenster, A
    MEDICAL PHYSICS, 2003, 30 (07) : 1580 - 1591