SYSTEMATIC REVIEW OF TIP APEX DISTANCE (TAD) IN DYNAMIC HIP SCREW (DHS) FIXATION OF OSTEOPOROTIC HIP FRACTURES

被引:0
|
作者
Abdulkareem, Imran Haruna [1 ]
机构
[1] Univ Leeds, Teaching Hosp, Leeds, W Yorkshire, England
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:S606 / S607
页数:2
相关论文
共 50 条
  • [1] Value of Tip-Apex Distance (TAD) in the Fixation of Intertrochanteric Fractures by Dynamic Hip Screw (DHS)
    Khairy, Hossam Mohamed
    El-Alfy, Ali Tawfik
    El-Malt, Ahmed Elsayed
    Samy, Ramy Nabil
    [J]. ARCHIVES OF PHARMACY PRACTICE, 2019, 10 (03) : 81 - 86
  • [2] Audit of Tip-Apex Distance in Dynamic Hip Screw Fixation of Proximal Femoral Fractures
    Potter, M.
    Hickey, B.
    [J]. BRITISH JOURNAL OF SURGERY, 2024, 111
  • [3] The prognostic value of tip-to-apex distance (TAD index) in intertrochanteric fractures fixed by dynamic hip screw
    Sedighi, Ali
    Sales, Jafar Ganjpour
    Alavi, Sahar
    [J]. ORTHOPEDIC REVIEWS, 2012, 4 (04) : 143 - 145
  • [4] 10Tip-Apex Distance in DHS & IM Nail Fixations for Hip Fractures
    Tan, G.
    Ong, C. T.
    Kainth, G.
    [J]. BRITISH JOURNAL OF SURGERY, 2022, 109
  • [5] Osteosynthesis of Intracapsular Femoral Neck Fractures by Dynamic Hip Screw (DHS) Fixation
    Majernicek, M.
    Dungl, P.
    Kolman, J.
    Malkus, T.
    Vaculik, J.
    [J]. ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2009, 76 (04) : 319 - 325
  • [6] To Study the Effectiveness and Safety of Dynamic Hip Screw (DHS) Fixation for Intertrochanteric Fractures
    Awan, Malik Mohammad Yasin
    Amjad, Mohammad
    Shah, Abdullah
    Ahmed, Ijaz
    Shad, Muhammad Nauman
    Fatima, Ajaz
    [J]. PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2019, 13 (02): : 342 - 345
  • [7] Intertrochanteric fracture fixation with Dynamic Hip Screw: Is tip-apex distance measurement useful for predicting fixation failure?
    Goh, K. L.
    Zamzuri, Z.
    Ariff, Mohd S.
    Azril, Mohamed M. A.
    [J]. INTERNATIONAL MEDICAL JOURNAL MALAYSIA, 2016, 15 (01) : 31 - 34
  • [8] Correlation between Post-Operation Center-Trochanteric Distance (CTD) and Tip Apex Distance (TAD) changes in Intertrochanteric Fractures Treated by Dynamic Hip Screw
    Ebrahimpour, Adel
    Karimi, Amin
    Sadighi, Mehrdad
    Sajjadi, Mohammadreza Minator
    Okhovatpour, Mohammad Ali
    Sabbaghzadeh, Amir
    Zandi, Reza
    [J]. TRAUMA MONTHLY, 2019, 24 (06) : 32 - 37
  • [9] Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip
    Baumgaertner, MR
    Solberg, BD
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (06): : 969 - 971
  • [10] THE VALUE OF THE TIP-APEX DISTANCE IN PREDICTING FAILURE OF FIXATION OF PERITROCHANTERIC FRACTURES OF THE HIP
    BAUMGAERTNER, MR
    CURTIN, SL
    LINDSKOG, DM
    KEGGI, JM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (07): : 1058 - 1064