Development of Defined Microbial Population Standards Using Fluorescence Activated Cell Sorting for the Absolute Quantification of S. aureus Using Real-Time PCR

被引:6
|
作者
Martinon, Alice [1 ]
Cronin, Ultan P. [1 ]
Wilkinson, Martin G. [1 ]
机构
[1] Univ Limerick, Dept Life Sci, Limerick, Ireland
关键词
Quantification; Real-time PCR; Fluorescence activated cell sorting; DNA standards; Staphylococcus aureus; STAPHYLOCOCCUS-AUREUS; LISTERIA-MONOCYTOGENES; QUANTITATIVE PCR; FLOW-CYTOMETRY; RAPID DETECTION; SYBR GREEN; DNA; MILK; INHIBITION; POLYMERASE;
D O I
10.1007/s12033-011-9417-3
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In this article, four types of standards were assessed in a SYBR Green-based real-time PCR procedure for the quantification of Staphylococcus aureus (S. aureus) in DNA samples. The standards were purified S. aureus genomic DNA (type A), circular plasmid DNA containing a thermonuclease (nuc) gene fragment (type B), DNA extracted from defined populations of S. aureus cells generated by Fluorescence Activated Cell Sorting (FACS) technology with (type C) or without purification of DNA by boiling (type D). The optimal efficiency of 2.016 was obtained on Roche LightCycler(A (R)) 4.1. software for type C standards, whereas the lowest efficiency (1.682) corresponded to type D standards. Type C standards appeared to be more suitable for quantitative real-time PCR because of the use of defined populations for construction of standard curves. Overall, Fieller Confidence Interval algorithm may be improved for replicates having a low standard deviation in Cycle Threshold values such as found for type B and C standards. Stabilities of diluted PCR standards stored at -20A degrees C were compared after 0, 7, 14 and 30 days and were lower for type A or C standards compared with type B standards. However, FACS generated standards may be useful for bacterial quantification in real-time PCR assays once optimal storage and temperature conditions are defined.
引用
收藏
页码:62 / 71
页数:10
相关论文
共 50 条
  • [1] Development of Defined Microbial Population Standards Using Fluorescence Activated Cell Sorting for the Absolute Quantification of S. aureus Using Real-Time PCR
    Alice Martinon
    Ultan P. Cronin
    Martin G. Wilkinson
    Molecular Biotechnology, 2012, 50 : 62 - 71
  • [2] A method for the absolute quantification of cDNA using real-time PCR
    Whelan, JA
    Russell, NB
    Whelan, MA
    JOURNAL OF IMMUNOLOGICAL METHODS, 2003, 278 (1-2) : 261 - 269
  • [3] Quantification of microbial communities in groundwater using real-time PCR
    Asano, Takahiro
    Sasaki, Yoshito
    Yoshikawa, Hideki
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2009, 73 (13) : A57 - A57
  • [4] Quantification of disease progression of several microbial pathogens on Arabidopsis thaliana using real-time fluorescence PCR
    Brouwer, M
    Lievens, B
    Van Hemelrijck, W
    Van den Ackerveken, G
    Cammue, BPA
    Thomma, BPHJ
    FEMS MICROBIOLOGY LETTERS, 2003, 228 (02) : 241 - 248
  • [5] Absolute quantification of gene expression in biomaterials research using real-time PCR
    Leong, David Tai
    Gupta, Anurag
    Bai, Hui Fen
    Wan, Guoqiang
    Yoong, Li Foong
    Too, Heng-Phon
    Chew, Fook Tim
    Hutmacher, Dietmar Werner
    BIOMATERIALS, 2007, 28 (02) : 203 - 210
  • [6] Development of absolute quantification method for genotype-specific Babesia microti using real-time PCR and practical experimental tips of real-time PCR
    Ohmori, Shiho
    Nagano-Fujii, Motoko
    Saito-Ito, Atsuko
    PARASITOLOGY INTERNATIONAL, 2016, 65 (05) : 567 - 571
  • [7] Food matrix standards for the quantification of allergenic food ingredients using real-time PCR
    Siegel, Marion
    Mutschler, A.
    Boernsen, B.
    Pietsch, Klaus
    Waiblinger, Hans-Ulrich
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2013, 237 (02) : 185 - 197
  • [8] Food matrix standards for the quantification of allergenic food ingredients using real-time PCR
    Marion Siegel
    A. Mutschler
    B. Boernsen
    Klaus Pietsch
    Hans-Ulrich Waiblinger
    European Food Research and Technology, 2013, 237 : 185 - 197
  • [9] Optotracing for selective fluorescence-based detection, visualization and quantification of live S. aureus in real-time
    Karen Butina
    Ana Tomac
    Ferdinand X. Choong
    Hamid Shirani
    K. Peter R. Nilsson
    Susanne Löffler
    Agneta Richter-Dahlfors
    npj Biofilms and Microbiomes, 6
  • [10] Development of Plasmid Calibrators for Absolute Quantification of miRNAs by Using Real-Time qPCR
    Formisano-Treziny, Christine
    de San Feliciano, Marina
    Gabert, Jean
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2012, 14 (04): : 314 - 321