A comparison of punching shear strengthening of RC flat plates with FRP bars and steel bolts

被引:6
|
作者
Yooprasertchai, Ekkachai [1 ]
Piamkulvanit, Mawin [1 ]
Srithong, Chanathip [1 ]
Sukcharoen, Teerathamrong [1 ]
Sahamitmongkol, Raktipong [1 ]
机构
[1] King Mongkuts Univ Technol Thonburi, Construct Innovat & Future Infrastruct Res Ctr CI, Dept Civil Engn, Fac Engn, Bangkok 10140, Thailand
关键词
Strengthening; Punching shear; Flat plate structures; CFRP; AFRP; Steel bolts; SLAB-COLUMN CONNECTIONS; REINFORCED-CONCRETE SLABS; PERFORMANCE; BEHAVIOR; BEAMS; RETROFIT;
D O I
10.1016/j.cscm.2021.e00828
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study investigated the behavior of carbon fiber-reinforced polymer (CFRP), aramid fiberreinforced polymer (AFRP) bars and steel bolts as post-installed shear reinforcements for strengthening flat plate structures to evaluate their cost and performance effectiveness via a series of monotonic load tests. Seven interior slab-column connections with a square column including one control specimen and six strengthened specimens with a single-line cruciform shear reinforcement were tested. Two shear reinforcement ratio conditions were examined, which comprised four and seven bars on each side of the column corresponding to 0.75 and 0.5 times the effective slab depth, respectively. The results were compared with the well-established design guidelines, revealing that the shear capacity of the specimens with post-installed shear reinforcement increased to a level where the failure mode changed from punching shear to flexure, resulting in more ductile behavior of the specimens. Additionally, the critical shear crack theory was used to characterize the performance of the specimens; the experimental results agreed well with the theory. The study indicated that FRP materials are competitive compared to the steel material.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Experimental and numerical study into the punching shear strengthening of RC flat slabs using post-installed steel bolts
    Saleh, Haifa
    Kalfat, Robin
    Abdouka, Kamiran
    Al-Mahaidi, Riadh
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 188 : 28 - 39
  • [2] Strengthening of flat slabs with FRP fan for punching shear
    Meisami, M. Hasan
    Mostofinejad, Davood
    Nakamura, Hikaru
    COMPOSITE STRUCTURES, 2015, 119 : 305 - 314
  • [3] Review of Punching Shear Behaviour of Flat Slabs Reinforced with FRP Bars
    Mohamed, Osama A.
    Khattab, Rania
    WORLD MULTIDISCIPLINARY CIVIL ENGINEERING-ARCHITECTURE-URBAN PLANNING SYMPOSIUM - WMCAUS, 2017, 245
  • [4] Punching shear strengthening of flat slabs with EBROG and EBRIG - FRP strips
    Amiri, Somayeh
    Talaeitaba, Sayed Behzad
    STRUCTURES, 2020, 26 : 139 - 155
  • [5] Cracking and punching shear failure analysis of RC flat plates
    Loo, YC
    Guan, H
    JOURNAL OF STRUCTURAL ENGINEERING, 1997, 123 (10) : 1321 - 1330
  • [6] A rational formula to predict punching shear capacity at interior columns connections with RC flat slabs reinforced with either steel or FRP bars but without shear reinforcement
    Alrudaini, Thaer M. Saeed
    STRUCTURES, 2022, 37 : 56 - 68
  • [7] Experimental and Numerical Analysis of the Punching Shear Resistance Strengthening of Concrete Flat Plates by Steel Collars
    Abdulhussein, Ahmed Aziz
    Al-Sherrawi, Mohannad H.
    ENGINEERING TECHNOLOGY & APPLIED SCIENCE RESEARCH, 2021, 11 (06) : 7853 - 7860
  • [8] Punching Shear Strengthening of RC Flat Plate with Ferrocement Drop Panel
    Sirimontree, Sayan
    Witchayangkoon, Boonsap
    Lertpocasombut, Krittiya
    INTERNATIONAL TRANSACTION JOURNAL OF ENGINEERING MANAGEMENT & APPLIED SCIENCES & TECHNOLOGIES, 2016, 7 (02): : 81 - 88
  • [9] Punching shear strength of UHPFRC-RC composite flat plates
    Wu, Xiangguo
    Yu, Shiyan
    Xue, Shicheng
    Kang, Thomas H. -K.
    Hwang, Hyeon-Jong
    ENGINEERING STRUCTURES, 2019, 184 : 278 - 286
  • [10] Rational prediction of punching shear strength of slabs reinforced with steel or FRP bars
    Lee, J-H
    Yang, J-M
    Yoon, Y-S
    MAGAZINE OF CONCRETE RESEARCH, 2010, 62 (11) : 821 - 830