A dual reflective electrothermal MEMS micromirror for full circumferential scanning endoscopic imaging - art. no. 688508

被引:0
|
作者
Wu, Lei [1 ]
Xie, Huikai [1 ]
机构
[1] Univ Florida, Dept Elect & Comp Engn, Gainesville, FL 32611 USA
关键词
MEMS; full circumferential scanning; dual reflective; micromirror; endoscopy; OCT;
D O I
10.1117/12.769621
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
This paper reports the design, fabrication and measurements of a dual-reflective, single-crystal silicon based micromirror that can perform full circumferential scanning (FCS) for endoscopic optical coherence tomography (EOCT). In the proposed FCS-EOCT probe, two optical fibers are used to deliver light beams to either surface of the micromirror, which can rotate +/- 45 degrees (or 90 degrees) and thus a 180 degrees optical scanning is obtained from each mirror surface, resulting in full circumferential scans. A novel surface- and bulk-combined micromachining process based on SOI wafers is developed for fabricating the dual reflective micromirror. The single-crystal-silicon device layer of SOI wafers is used for mirror flatness, and A1 is coated on both sides for high reflectivity. With one light beam delivered to each mirror surface, full 360 degrees scans have been observed. Other measured data include the resonant frequency: 328Hz, radius of curvatures: 124 mm (front surface) and 127 mm (back surface), and the reflectances: 81.3% (front surface) and 79.0% (back surface).
引用
收藏
页码:88508 / 88508
页数:8
相关论文
共 37 条
  • [1] Electrothermal micromirror with dual-reflective surfaces for circumferential scanning endoscopic imaging
    Wu, Lei
    Xie, Huikai
    JOURNAL OF MICRO-NANOLITHOGRAPHY MEMS AND MOEMS, 2009, 8 (01):
  • [2] The fractal charactor of micromirror for metal MEMS optical switch - art. no. 662409
    Zhang Yi
    Luo Yuan
    Xu Xiaodong
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2007: OPTOELECTRONIC SYSTEM DESIGN, MANUFACTURING, AND TESTING, 2008, 6624 : 62409 - 62409
  • [3] MEMS ultrasonic probe rotary scanning imaging system for medical endoscope - art. no. 635818
    Chen Xiaodong
    Wen Shijie
    Yu Daoyin
    Sensors, Automatic Measurement, Control, and Computer Simulation, Pts 1 and 2, 2006, 6358 : 35818 - 35818
  • [4] Dynamic focus-tracking MEMS scanning micromirror with low actuation voltages for endoscopic imaging
    Strathman, Matthew
    Liu, Yunbo
    Li, Xingde
    Lin, Lih Y.
    OPTICS EXPRESS, 2013, 21 (20): : 23934 - 23941
  • [5] Slow scanning electromagnetic MEMS scanner for laser display - art. no. 688704
    Jeong, Hee-Moon
    Park, Yong-Hwa
    Jeong, Hyun-Ku
    Cho, Yong-Chul
    Chang, Seok-Mo
    Kim, Jun-O
    Kang, Seok-Jin
    Hwang, Jun-Sik
    Lee, Jin-Ho
    MOEMS AND MINIATURIZED SYSTEMS VII, 2008, 6887 : 88704 - 88704
  • [6] MEMS membrane mirrors for focus adjustment and aberration correction in endoscopic confocal and OCT imaging instruments - art. no. 646707
    Dickensheets, David L.
    MEMS Adaptive Optics, 2007, 6467 : 46707 - 46707
  • [7] Broadband endoscopic imaging through a single fiberoptic channel - art. no. 666806
    Kano, Angelique
    Koshel, John
    Gmitro, Arthur F.
    NOVEL OPTICAL SYSTEMS DESIGN AND OPTIMIZATION X, 2007, 6668 : 66806 - 66806
  • [8] Infrared dual spectral imaging system - art. no. 68350Q
    Wang Hai-tao
    Geng An-bing
    Yang Chang-cheng
    Cao Qiong
    Guo Liang-xian
    INFRARED MATERIALS, DEVICES, AND APPLICATIONS, 2007, 6835 : Q8350 - Q8350
  • [9] Scanning magnetic imaging of Sr2RuO4 -: art. no. 012504
    Björnsson, PG
    Maeno, Y
    Huber, ME
    Moler, KA
    PHYSICAL REVIEW B, 2005, 72 (01)
  • [10] Development of Dual Imaging Optical Sensor (DIOS) for small satellites - art. no. 667719
    Choi, Young-Wan
    Kang, Myung-Seok
    Jeong, Sung-Keun
    Yun, Ji-Ho
    Yang, Seung-Uk
    Kim, Jongun
    Kim, Ee-Eul
    EARTH OBSERVING SYSTEMS XII, 2007, 6677 : 67719 - 67719