The computer-aided parallel external fixator for complex lower limb deformity correction

被引:18
|
作者
Wei, Mengting [1 ]
Chen, Jianwen [2 ,3 ]
Guo, Yue [2 ,3 ]
Sun, Hao [1 ]
机构
[1] Hebei Univ Technol, Sch Control Sci & Engn, 8 Guangrong Rd, Tianjin 300130, Peoples R China
[2] Natl Res Ctr Rehabil Tech Aids, Rehabil Hosp, 1 Ronghua Middle Rd, Beijing 100176, Peoples R China
[3] Minist Civil Affairs, Key Lab Human Mot Anal & Rehabil Technol, 1 Ronghua Middle Rd, Beijing 100176, Peoples R China
基金
“十二五”国家科技支撑计划重点项目”;
关键词
Bone external fixator; Stewart platform; Virtual reality technology; Deformity correction; TAYLOR SPATIAL FRAME; STEWART PLATFORM; ILIZAROV METHOD; TIBIA VARA; DISTRACTION; MANIPULATOR; MANAGEMENT; CHILDREN; FRACTURE;
D O I
10.1007/s11548-017-1654-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Since parameters of the parallel external fixator are difficult to measure and calculate in real applications, this study developed computer software that can help the doctor measure parameters using digital technology and generate an electronic prescription for deformity correction. According to Paley's deformity measurement method, we provided digital measurement techniques. In addition, we proposed an deformity correction algorithm to calculate the elongations of the six struts and developed a electronic prescription software. At the same time, a three-dimensional simulation of the parallel external fixator and deformed fragment was made using virtual reality modeling language technology. From 2013 to 2015, fifteen patients with complex lower limb deformity were treated with parallel external fixators and the self-developed computer software. All of the cases had unilateral limb deformity. The deformities were caused by old osteomyelitis in nine cases and traumatic sequelae in six cases. A doctor measured the related angulation, displacement and rotation on postoperative radiographs using the digital measurement techniques. Measurement data were input into the electronic prescription software to calculate the daily adjustment elongations of the struts. Daily strut adjustments were conducted according to the data calculated. The frame was removed when expected results were achieved. Patients lived independently during the adjustment. The mean follow-up was 15 months (range 10-22 months). The duration of frame fixation from the time of application to the time of removal averaged 8.4 months (range 2.5-13.1 months). All patients were satisfied with the corrected limb alignment. No cases of wound infections or complications occurred. Using the computer-aided parallel external fixator for the correction of lower limb deformities can achieve satisfactory outcomes. The correction process can be simplified and is precise and digitized, which will greatly improve the treatment in a clinical application.
引用
收藏
页码:2107 / 2117
页数:11
相关论文
共 50 条
  • [1] The computer-aided parallel external fixator for complex lower limb deformity correction
    Mengting Wei
    Jianwen Chen
    Yue Guo
    Hao Sun
    International Journal of Computer Assisted Radiology and Surgery, 2017, 12 : 2107 - 2117
  • [2] Deformity correction and lengthening of lower legs with an external fixator
    Matsubara, Hidenori
    Tsuchiya, Hiroyuki
    Sakurakichi, Keisuke
    Watanabe, Koji
    Tomita, Katsuro
    INTERNATIONAL ORTHOPAEDICS, 2006, 30 (06) : 550 - 554
  • [3] Deformity correction and lengthening of lower legs with an external fixator
    Hidenori Matsubara
    Hiroyuki Tsuchiya
    Keisuke Sakurakichi
    Koji Watanabe
    Katsuro Tomita
    International Orthopaedics, 2006, 30 : 550 - 554
  • [4] Acute correction of lower limb deformity and simultaneous lengthening with a monolateral fixator
    Donnan, LT
    Saleh, M
    Rigby, AS
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (02): : 254 - 260
  • [5] Deformity correction with external fixator in pseudoachondroplasia
    Li, Qi-Wei
    Song, Hae-Ryong
    Mahajan, Ravindra H.
    Suh, Seung-Woo
    Lee, Seok-Hyun
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (454) : 174 - 179
  • [6] Use of an external ring fixator for correction of an acquired angular limb deformity in a donkey
    Eggleston, RB
    Mueller, POE
    Chambers, JN
    Bentley, A
    JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2000, 217 (08): : 1186 - +
  • [7] Complex rigid foot deformity correction with hexapod external fixator system
    Sancar Bakircioglu
    Murat Danisman
    Ozan Tuncay
    Ulas Can Kolac
    Muhammed Abdulkadir Bulut
    Guney Yilmaz
    International Orthopaedics, 2023, 47 : 2773 - 2780
  • [8] Complex rigid foot deformity correction with hexapod external fixator system
    Bakircioglu, Sancar
    Danisman, Murat
    Tuncay, Ozan
    Kolac, Ulas Can
    Bulut, Muhammed Abdulkadir
    Yilmaz, Guney
    INTERNATIONAL ORTHOPAEDICS, 2023, 47 (11) : 2773 - 2780
  • [9] A hexapod robot external fixator for computer assisted fracture reduction and deformity correction
    Seide, K
    Faschingbauer, M
    Wenzl, ME
    Weinrich, N
    Juergens, C
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2004, 1 (01): : 64 - 69
  • [10] Computer-aided Navigation for Correction of Glenoid Deformity in Total Shoulder Arthroplasty
    Stanley, Rodney J.
    Edwards, T. Bradley
    Sarin, Vineet K.
    Gartsman, Gary M.
    TECHNIQUES IN SHOULDER AND ELBOW SURGERY, 2007, 8 (01): : 23 - 28