MRI quality assurance based on 3D FLAIR brain images

被引:5
|
作者
Peltonen, Juha I. [1 ,2 ]
Makela, Teemu [1 ,3 ]
Salli, Eero [1 ]
机构
[1] Univ Helsinki, Helsinki Univ Hosp, HUS Med Imaging Ctr, Radiol, POB 340, FI-00029 Helsinki, Finland
[2] Aalto Univ, Sch Sci, Dept Neurosci & Biomed Engn, POB 12200, FI-00076 Espoo, Finland
[3] Univ Helsinki, Dept Phys, POB 64, FI-00014 Helsinki, Finland
关键词
Magnetic resonance imaging; Quality assurance; Quality control; Computer-assisted image analysis; MAGNETIC-RESONANCE IMAGES; SUBARACHNOID HEMORRHAGE; SPATIAL-RESOLUTION; SEQUENCES; OPTIMIZATION; SENSITIVITY; PREVALENCE; CONTRAST;
D O I
10.1007/s10334-018-0699-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectiveQuality assurance (QA) of magnetic resonance imaging (MRI) often relies on imaging phantoms with suitable structures and uniform regions. However, the connection between phantom measurements and actual clinical image quality is ambiguous. Thus, it is desirable to measure objective image quality directly from clinical images.Materials and methodsIn this work, four measurements suitable for clinical image QA were presented: image resolution, contrast-to-noise ratio, quality index and bias index. The methods were applied to a large cohort of clinical 3D FLAIR volumes over a test period of 9.5 months. The results were compared with phantom QA. Additionally, the effect of patient movement on the presented measures was studied.ResultsA connection between the presented clinical QA methods and scanner performance was observed: the values reacted to MRI equipment breakdowns that occurred during the study period. No apparent correlation with phantom QA results was found. The patient movement was found to have a significant effect on the resolution and contrast-to-noise ratio values.DiscussionQA based on clinical images provides a direct method for following MRI scanner performance. The methods could be used to detect problems, and potentially reduce scanner downtime. Furthermore, with the presented methodologies comparisons could be made between different sequences and imaging settings. In the future, an online QA system could recognize insufficient image quality and suggest an immediate re-scan.
引用
收藏
页码:689 / 699
页数:11
相关论文
共 50 条
  • [1] MRI quality assurance based on 3D FLAIR brain images
    Juha I. Peltonen
    Teemu Mäkelä
    Eero Salli
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2018, 31 : 689 - 699
  • [2] Improving the image quality of 3D FLAIR with a spiral MRI technique
    Li, Zhiqiang
    Pipe, James G.
    Ooi, Melvyn B.
    Kuwabara, Michael
    Karis, John P.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (01) : 170 - 177
  • [3] A knowledge-based system for brain tumor segmentation using only 3D FLAIR images
    Yalda Amirmoezzi
    Sina Salehi
    Hossein Parsaei
    Kamran Kazemi
    Amin Torabi Jahromi
    Australasian Physical & Engineering Sciences in Medicine, 2019, 42 : 529 - 540
  • [4] A knowledge-based system for brain tumor segmentation using only 3D FLAIR images
    Amirmoezzi, Yalda
    Salehi, Sina
    Parsaei, Hossein
    Kazemi, Kamran
    Jahromi, Amin Torabi
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2019, 42 (02) : 529 - 540
  • [5] Brain age estimation based on 3D MRI images using 3D convolutional neural network
    Pardakhti, Nastaran
    Sajedi, Hedieh
    MULTIMEDIA TOOLS AND APPLICATIONS, 2020, 79 (33-34) : 25051 - 25065
  • [6] Brain age estimation based on 3D MRI images using 3D convolutional neural network
    Nastaran Pardakhti
    Hedieh Sajedi
    Multimedia Tools and Applications, 2020, 79 : 25051 - 25065
  • [7] Diagnosing perilymphatic fistula with 3D flair MRI
    Kemps, Glen
    Mistry, Jayran
    Connor, Steve
    Obholzer, Rupert
    Ainsworth, Carolyn
    HEARING BALANCE AND COMMUNICATION, 2023, 21 (03) : 175 - 177
  • [8] A hybrid method for 3D segmentation of MRI Brain Images
    Zhang, X
    Zhang, DZ
    Tian, JW
    Liu, J
    2002 6TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING PROCEEDINGS, VOLS I AND II, 2002, : 608 - 611
  • [9] 3D brain tumor segmentation in MRI images based on a modified PSO technique
    Gtifa, Wafa
    Hamdaoui, Faycal
    Sakly, Anis
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2019, 29 (04) : 501 - 509
  • [10] Comparison of wavelet based coders applied to 3D Brain Tumor MRI Images
    Dhouib, D.
    Nait-Ali, A.
    Olivier, C.
    Naceur, M. S.
    2009 6TH INTERNATIONAL MULTI-CONFERENCE ON SYSTEMS, SIGNALS AND DEVICES, VOLS 1 AND 2, 2009, : 751 - +