Analysis of saving energy of fresh air ventilator

被引:0
|
作者
Ren, Shaobo [1 ]
Zhao, Jingye [1 ]
机构
[1] Beijing Inst Civil Engn & Architecture, Dept Environm & Energy Engn, Beijing 100044, Peoples R China
关键词
fresh air ventilator; energy saving; heat transfer; indoor air quality;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Sick Building Syndrome by lack of fresh air in traditional ways of air conditioning caused people's worrying about the indoor air quality, and made it imposible to realize a comfortable environment created by air conditioning. On the contrary, supplying a large quantity of outdoor air,regardless of fluctuation in building occupancy,is a wasteful strategy; Meantime more air means more investing and operating charges. A heat recoverable equipment, Fresh Air Ventilator(FAV), which can provide thermal comfort, and decrease energy consumption of the air conditioning system. In this paper the FAV could be introduced to complement existing air conditioning systems, the focus of this paper is on the characteristics of FAV for replacement of Fresh Air Units(FAU) Furthermore, Some difficulties in design of the new system such as air balance, frost deposit and so on, should be taken into account. With the advantages of Fresh Air Ventilator, we can get better indoor air quality, more effective energy.
引用
收藏
页码:673 / 676
页数:4
相关论文
共 50 条
  • [1] Piston wind and energy saving based on the analysis of fresh air in the subway system
    He, Deqiang
    Teng, Xiaoliang
    Chen, Yanjun
    Liu, Bin
    Wu, Jinxin
    [J]. SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 50
  • [2] Energy saving analysis on the recovery fresh air heat pump units of a public building
    Chen, Aoxue
    Liu, Hailong
    [J]. PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING II, PTS 1-4, 2013, 405-408 : 2955 - +
  • [3] Energy-saving analysis of cold and heat recovery of the full fresh air dehumidifier
    Kang, Zhiqiang
    Li, Jingqi
    Li, Zhixing
    Feng, Guohui
    [J]. 10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 4117 - 4121
  • [4] Simple and reliable energy saving AC fresh air control scheme
    Wang, L
    Ma, L
    Yang, TQ
    [J]. PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 1491 - 1497
  • [5] Analysis of Air Conditioning Energy Saving Measures
    Li, Siqi
    Li, Rui
    [J]. CONSTRUCTION AND URBAN PLANNING, PTS 1-4, 2013, 671-674 : 2526 - 2529
  • [6] A novel turbine ventilator with a damper regulator to adjust exhausted air for energy-saving in buildings
    Wang, Bohong
    Klemes, Jiri Jaromir
    Malasek, Jiri
    Hemzal, Milan
    Liang, Yongtu
    Zeng, Min
    [J]. JOURNAL OF BUILDING ENGINEERING, 2021, 38
  • [7] Energy saving potential of fresh air pre-handling system using shallow geothermal energy
    Lyu, Weihua
    Li, Xianting
    Wang, Baolong
    Shi, Wenxing
    [J]. ENERGY AND BUILDINGS, 2019, 185 : 39 - 48
  • [8] Energy-saving performance of modified heat recovery ventilator in air conditioner cooling rabbit house
    Liu, Peng
    Wu, Zhonghong
    Tang, Yuhan
    An, Lei
    Liu, Jijun
    Tian, Jianhui
    [J]. Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2019, 35 (05): : 197 - 202
  • [9] Research and Application of Controlling System of Fresh Air Antifreezing and Energy-Saving of Heating Air Conditioning in Winter
    Ping, Jiang
    [J]. 2011 INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SYSTEMS SCIENCE AND ENGINEERING (ICESSE 2011), VOL 1, 2011, : 154 - 157
  • [10] Energy saving air separation plant based on exergy analysis
    Taniguchi, Masaaki
    Asaoka, Hitoshi
    Ayuhara, Toshiyuki
    [J]. R and D: Research and Development Kobe Steel Engineering Reports, 2014, 64 (01): : 45 - 48