Physical characterization of Peripherally-Inserted Central Catheters (PICC)

被引:0
|
作者
Rosa Mitelmao, Fabiana Cristina [1 ]
Mangini Filho, Salvador [1 ]
Chaud, Marco Vinicius [2 ]
Duarte Carvalho Vila, Marta Maria [3 ]
Cardoso Figueiredo Balcao, Victor Manuel [3 ,4 ,5 ]
de Oliveira Junior, Jose Martins [1 ]
机构
[1] Univ Sorocaba, LaFINAU Lab Appl Nucl Phys, BR-18023000 Sorocaba, SP, Brazil
[2] Univ Sorocaba, LaBNUS Lab Biomat & Nanotechnol, Technol Pk Sorocaba, BR-18078005 Sorocaba, SP, Brazil
[3] Univ Sorocaba, PhageLab Lab Biotilms & Bacteriophages, BR-18023000 Sorocaba, SP, Brazil
[4] Univ Aveiro, Dept Biol, Campus Univ Santiago, P-3810193 Aveiro, Portugal
[5] Univ Aveiro, CESAM, Campus Univ Santiago, P-3810193 Aveiro, Portugal
来源
MATERIA-RIO DE JANEIRO | 2020年 / 25卷 / 01期
基金
巴西圣保罗研究基金会;
关键词
Mechanical testing; Tension test; X-ray reflectivity; Deformation; Elastic properties; Polymers;
D O I
10.1590/S1517-707620200001.0870
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Peripherally-inserted central catheters (PICC) are widely used in neonates hospitalized in Neonatal Intensive Care Units (NICU). The aim of the study entertained herein was to evaluate the physical characteristics of PICC, through application of the standards ABNT NBR ISO 10555-1:2003 and ABNT NBR ISO 10555-3:2003, and compare the results produced in the analysis of PICC at the beginning of their production process (extruded catheters only) with those obtained in the analysis of the finished product. Experimental tests were performed in PICC manufactured by a domestic manufacturer between the years 2011 and 2012. The data was gathered from tests performed on both catheters that were just extruded, i.e. without painting the demarcations, cutting and other processes related with quality assurance, and on catheters after completion of the overall manufacturing process. In the present study, one included all stages of the catheter production process that can generate some type of modification in the product that could impart risks to the patients needing to use them. The catheters were analyzed for strength to rupture, radiopacity, flow characteristics, leakage of fluid under pressure, and occurrence of air leak in the suction tube assembly, as advocated by the NBR ISO 10555-1:2003 and NBR ISO 10555-3:2003 standards The results obtained were satisfactory in all analyses performed, except for the resistance to rupture, which did not meet the specifications advocated by the standards for catheters made of silicone. One has also examined catheters made of polyurethane, which in turn did meet the standards with regard to resistance to rupture. As standards do not specify important points to be taken into account for conducting tests unequivocally, suggestions were made for revision of those standards.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] PERIPHERALLY-INSERTED CENTRAL CATHETERS PLACED IN THE ICU
    Loza, A.
    Jimenez, P.
    Macias, D.
    Gonzalez, S.
    Lucena, F.
    Leon, C.
    Lesmes, A.
    [J]. INTENSIVE CARE MEDICINE, 2014, 40 : S145 - S145
  • [2] Peripherally-inserted central catheters in low weight infants
    Chigot, V
    Dubois, J
    Rypens, F
    Garel, LA
    [J]. RADIOLOGY, 2001, 221 : 148 - 148
  • [3] COMPLICATIONS OF PERIPHERALLY INSERTED CENTRAL CATHETERS (PICC)
    Varghese, R.
    Krishnareddy, K.
    Edke, U.
    Redona, V.
    Sara, S.
    [J]. INTENSIVE CARE MEDICINE, 2012, 38 : S184 - S184
  • [4] Nurses inserted picc (peripherally inserted central venous catheters)
    George, Mary
    [J]. EUROPEAN JOURNAL OF ONCOLOGY NURSING, 2008, 12 (02) : 164 - 164
  • [5] Nurses inserted PICC (Peripherally Inserted Central venous Catheters)
    George, Mary
    [J]. PEDIATRIC BLOOD & CANCER, 2007, 49 (04) : 423 - 424
  • [6] Peripherally inserted central catheters (PICC): a promising technique
    Vidal, V.
    Jacquier, A.
    Monnet, O.
    Varoquaux, A.
    Le Corroller, T.
    Gaubert, J. Y.
    Champsaur, P.
    Bartoli, J. M.
    Moulin, G.
    [J]. JOURNAL DE RADIOLOGIE, 2008, 89 (7-8): : 907 - 909
  • [7] Peripherally Inserted Central Catheters (PICC) for Multiple Blood Collections
    Segura, L. J.
    [J]. JOURNAL OF THE AMERICAN ASSOCIATION FOR LABORATORY ANIMAL SCIENCE, 2009, 48 (05): : 571 - 571
  • [8] Intravenous peripherally-inserted central catheters for antibiotic therapy in children with cystic fibrosis
    Bui, S.
    Babre, F.
    Hauchecorne, S.
    Christoflour, N.
    Ceccato, F.
    Boisserie-Lacroix, V.
    Clouzeau, H.
    Fayon, M.
    [J]. JOURNAL OF CYSTIC FIBROSIS, 2009, 8 (05) : 326 - 331
  • [9] USE OF PERIPHERALLY INSERTED CENTRAL CATHETERS IN INFANTS: PICC STUDY
    Chegondi, Madhuradhar
    Ness-Cochinwala, Manette
    Pinto, Matthew
    Schreiber, Hilary
    Polikoff, Lee
    Kerris, Elizabeth
    Kothari, Harsh
    Bloxham, Jodi
    Berman-Sieger, Abigail
    Mancuso, Bethany
    Harder, Tyler
    Korn, Sarah
    Gillette, Cheryl
    Taillie, Eileen
    Cholette, Jill
    Johnson, Rachel
    Kaipa, Santosh
    Faustino, E. Vincent
    [J]. CRITICAL CARE MEDICINE, 2024, 52
  • [10] A TEAM-BASED, MULTIDISCIPLINARY APPROACH TO REDUCING PERIPHERALLY-INSERTED CENTRAL CATHETERS (PICC) COMPLICATIONS IN HAEMATOLOGICAL PATIENTS:A PROSPECTIVE STUDY
    Natalia, N.
    Garcia Suarez, J.
    Guillen, H.
    Martin, Y.
    Callejas, M.
    Gil Fernandez, J. J.
    Magro, E.
    Flores, E.
    Calero, M.
    Lopez Rubio, M.
    Casco, C.
    Pascual, T.
    Arranz, J. J.
    Diaz, M. T.
    Burgaleta, C.
    [J]. HAEMATOLOGICA, 2012, 97 : 568 - 569