Grafting of phenylboronic acid on a glassy carbon electrode and its application as a reagentless glucose sensor

被引:22
|
作者
Morita, Kotaro [2 ]
Hirayama, Naoki [2 ]
Imura, Hisanori [2 ]
Yamaguchi, Akira [1 ]
Teramae, Norio [1 ]
机构
[1] Tohoku Univ, Grad Sch Sci, Dept Chem, Aoba Ku, Sendai, Miyagi 9808578, Japan
[2] Kanazawa Univ, Grad Sch Nat Sci & Technol, Div Mat Sci, Kanazawa, Ishikawa 9201192, Japan
关键词
In situ generated diazonium cation; Glassy carbon; Impedance spectroscopy; Phenylboronic acid; Glucose; ARYL DIAZONIUM SALTS; ELECTROCHEMICAL REDUCTION; COVALENT MODIFICATION; SEMICONDUCTIVE SURFACES; ARYLDIAZONIUM SALTS; CYCLIC VOLTAMMETRY; ORGANIC LAYERS; BORONIC ACIDS; FILMS; MONOLAYERS;
D O I
10.1016/j.jelechem.2010.11.023
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Phenylboronic acid (PBA) was covalently grafted to the surface of glassy carbon (GC) electrodes using electrochemical reduction of in situ generated diazonium cation. The grafting of GC surfaces was controlled by varying both the concentration of precursor 3-aminophenylboronic acid and the number of potential cycling during the grafting procedure. Cyclic voltammetry (CV) and eletrochemical impedance spectroscopy (EIS) were used to confirm the grafting of the PBA group to the GC surface and formation of multilayer. The barrier properties of the grafted GC electrodes were studied in the presence of a redox probe such as Fe(CN)(6)(3-/4-) by CV. Additionally, the resultant PBA multilayer on the GC electrode was applied for glucose detection utilizing the EIS technique in the presence of a redox probe molecule. Then, the complexation ability of the grafted layers with glucose was also confirmed as an increase of total impedance at non-faradic EIS measurement. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:192 / 197
页数:6
相关论文
共 50 条
  • [1] Reagentless alcohol sensor based on thionine-TDI modified glassy carbon electrode
    Yu, Ai-Min
    Han, Ji-Lin
    Yang, Ke-Sheng
    Chen, Hong-Yuan
    Kao Teng Hsueh Hsiao Hua Heush Hsueh Pao/ Chemical Journal of Chinese Universities, 1995, 16 (08):
  • [2] Electrochemical Determination of Glycoalkaloids Using a Carbon Nanotubes-Phenylboronic Acid Modified Glassy Carbon Electrode
    Wang, Huiying
    Liu, Mingyue
    Hu, Xinxi
    Li, Mei
    Xiong, Xingyao
    SENSORS, 2013, 13 (12): : 16234 - 16244
  • [3] A REAGENTLESS ALCOHOL SENSOR-BASED ON THIONINE-TDI MODIFIED GLASSY-CARBON ELECTRODE
    YU, AM
    HAN, JL
    YANG, KS
    CHEN, HY
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 1995, 16 (08): : 1204 - 1206
  • [4] Phenylboronic acid self-assembled layer on glassy carbon electrode for recognition of glycoprotein peroxidase
    Liu, SQ
    Miller, B
    Chen, AC
    ELECTROCHEMISTRY COMMUNICATIONS, 2005, 7 (12) : 1232 - 1236
  • [5] POLY-SALICYLIC ACID MODIFIED GLASSY-CARBON ELECTRODE AND ITS APPLICATION
    XU, JR
    ZHUANG, XR
    TALANTA, 1991, 38 (10) : 1191 - 1195
  • [6] Voltammetric behavior of quercetin on a glassy carbon electrode and its application
    Liu, YM
    Li, GZ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (08) : 1022 - 1022
  • [7] Voltammetric behavior of nitrendipine on glassy carbon electrode and its application
    Liu, YM
    Li, GZ
    Jing, JR
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (11) : 1341 - 1343
  • [8] Voltammetric Behavior of ethambutol on a glassy carbon electrode and its application
    Zhang, YN
    Yang, YF
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (07) : 857 - 860
  • [9] Preparation of phosphate-binding-protein-modified electrode and its application to reagentless phosphate sensor
    Kubo, I
    Satoh, D
    SENSORS AND MATERIALS, 2004, 16 (08) : 391 - 399
  • [10] Surface nanocrystallization of glassy carbon electrode: Application in direct electrochemistry of glucose oxidase
    Xu, Xiahong
    Chen, Jinhua
    Li, Wang
    Nie, Zhou
    Yao, Shouzhuo
    ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (10) : 1459 - 1462