Equivalence of hydroxyethyl starch HES 130/0.4 and HES 200/0.5 for perioperative volume replacement in major gynaecological surgery

被引:38
|
作者
Sander, O
Reinhart, K
Meier-Hellman, A
机构
[1] Helios Clin Erfurt GmbH, Dept Anaesthesiol Pain Therapy Intens Care Med, D-99089 Erfurt, Germany
[2] Univ Jena, Dept Anaesthesiol & Intens Care Med, D-6900 Jena, Germany
关键词
C2/C6; ratio; hydroxyethyl starch; molar substitution; perioperative haemodynamic stability;
D O I
10.1034/j.1399-6576.2003.00220.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Hydroxyethyl starch solutions (HES) are increasingly used for the compensation of surgical blood loss. The objective of this clinical trial was to compare a novel 6% HES 130/0.4 solution with a favourable pharmacological profile and a standard 6% HES 200/0.5 solution for maintenance of haemodynamic stability in major gynaecological surgery. Methods: Sixty female patients aged 18 - 80 years undergoing major gynaecological surgery with indication for perioperative colloidal volume replacement were enrolled in this prospective, randomized double-blinded clinical study. The administration of study medication was dependent on individual requirements to maintain haemodynamic stability. The amount of study medication required from induction of anaesthesia until 6 h postoperatively served as the primary investigative parameter. Results: The two one-sided test procedure by Westlake demonstrated equivalence of mean infused volumes between HES 130/0.4 and HES 200/0.5 during the study period ( 1224 +/- 544 ml and 1389 +/- 610 ml, respectively, P< 0.05). Perioperatively, haemodynamics did not differ significantly between treatment groups. While none of the mean values of coagulation parameters shifted outside the normal range, the degree of haemodilution revealed reduced haematocrit values in HES 200/0.5 treated patients at 6 h postoperatively ( P< 0.05). Moreover, prothrombin time ( PT) was higher and consequently international normalized ratio (INR) was lower at the same time point for patients who received HES 130/0.4 ( P< 0.05). Conclusion: This clinical trial demonstrated therapeutic equivalence of this novel low-substituted HES 130/0.4 solution and a standard HES 200/0.5 solution for perioperative volume replacement. Moreover, both HES preparations were equally well-tolerated and safe.
引用
收藏
页码:1151 / 1158
页数:8
相关论文
共 50 条
  • [1] Influence of Hydroxyethyl Starch (6% HES 200/0.5 and 6% HES 130/0.4) on Perioperative Renal Function of Orthotopic Liver Transplant
    Yang, Lu
    Niu, Li-Jun
    Tam, Nga-Lei
    Huang, Wen-Qi
    Ye, Jian-Hong
    Wu, Lin-Wei
    LIVER TRANSPLANTATION, 2010, 16 (06) : S220 - S220
  • [2] Voluven®, a lower substituted novel hydroxyethyl starch (HES 130/0.4), causes fewer effects on coagulation in major orthopedic surgery than HES 200/0.5
    Langeron, O
    Doelberg, M
    Ang, ET
    Bonnet, F
    Capdevila, X
    Coriat, P
    ANESTHESIA AND ANALGESIA, 2001, 92 (04): : 855 - 862
  • [3] Hydroxyethyl starch (HES) 130/0.4 during acute normovolemic hemodilution increases tissue oxygen tension larger and faster than HES 70/0.5 or HES 200/0.5 - Response
    Standl, T
    ANESTHESIA AND ANALGESIA, 2004, 98 (02): : 559 - 560
  • [4] Volume replacement during major orthopedic surgery: a new 6% hydroxyethyl starch solution (HES 130/0.4) might reduce blood loss
    Langeron, O
    Hbitz, D
    Faure, E
    Marty, J
    Coriat, P
    BRITISH JOURNAL OF ANAESTHESIA, 1999, 82 : 74 - 74
  • [5] The influence of two different hydroxyethyl starch solutions (6% HES 130/0.4 and 200/0.5) on blood viscosity
    Neff, TA
    Fischler, L
    Mark, M
    Stocker, R
    Reinhart, WH
    ANESTHESIA AND ANALGESIA, 2005, 100 (06): : 1773 - 1780
  • [6] Plasma substitution effects of a new hydroxyethyl starch HES 130/0.4 compared with HES 200/0.5 during and after extended acute normovolaemic haemodilution
    Ickx, BE
    Bepperling, F
    Melot, C
    Schulman, C
    Van der Linden, PJ
    BRITISH JOURNAL OF ANAESTHESIA, 2003, 91 (02) : 196 - 202
  • [7] Efficacy and safety of 10% HES 130/0.4 versus 10% HES 200/0.5 for plasma volume expansion in cardiac surgery patients
    C Ertmer
    H Van Aken
    H Wulf
    P Friederich
    C Mahl
    F Bepperling
    M Westphal
    W Gogarten
    Critical Care, 15 (Suppl 1):
  • [8] Tissue Storage of 14C-Labelled Hydroxyethyl Starch (HES) 130/0.4 and HES 200/0.5 after Repeated Intravenous Administration to Rats
    Jost Leuschner
    Jens Opitz
    Andreas Winkler
    Roland Scharpf
    Frank Bepperling
    Drugs in R & D, 2003, 4 (6) : 331 - 338
  • [9] Efficacy and safety of 10% HES 130/0.4 versus 10% HES 200/0.5 for plasma volume expansion in cardiac surgery patients
    Ertmer, C.
    Wulf, H.
    Van Aken, H.
    Friederich, P.
    Mahl, C.
    Bepperling, F.
    Westphal, M.
    Gogarten, W.
    MINERVA MEDICA, 2012, 103 (02) : 111 - 122
  • [10] Effects of two different hydroxyethyl starch solutions (HES200/0.5 vs. HES130/0.4) on the expression of platelet membrane glycoprotein
    Chen, G.
    Yan, M.
    Lu, Q. H.
    Gong, M.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2006, 50 (09) : 1089 - 1094