Wireless body sensor network for continuous cuff-less blood pressure monitoring

被引:16
|
作者
Espina, Javier [1 ]
Falck, Thomas [1 ]
Muehlsteff, Jens [1 ]
Aubert, Xavier [1 ]
机构
[1] Philips Res Europe, PO 500145, D-52085 Aachen, Germany
关键词
D O I
10.1109/ISSMDBS.2006.360085
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes an unobtrusive IEEE 802.15.4-based wireless Body Sensor Network (BSN) that enables continuous cuff-less blood pressure monitoring, opening up new perspectives for hypertension diagnosis and treatment, cardio-vascular event detection, and stress monitoring. We estimate the arterial blood pressure based on the Pulse Arrival Time (PAT), which is measured with a waist electrocardiogram (ECG) and an ear photo-plethysmogram (PPG). The PAT measurement requires the synchronization of the wireless sensors' clocks. This is achieved with the Flooding Time Synchronization Protocol (FTSP). The evaluation of both the implemented time synchronization and the robustness of the wireless data transmission yielded promising results. Future work will include the study of packet collisions in synchronized IEEE 802.15.4 networks, the enhancement of the BSN with additional context-providing sensors (e.g. accelerometer, magnetometer, thermistor), and the integration of the blood pressure estimation algorithm in a wireless sensor unit.
引用
收藏
页码:11 / +
页数:2
相关论文
共 50 条
  • [1] Wearable Body Sensor Network towards Continuous Cuff-less Blood Pressure Monitoring
    Espina, Javier
    Falck, Thomas
    Muehlsteff, Jens
    Jin, Yilin
    Adan, Miguel A.
    Aubert, Xavier
    2008 5TH INTERNATIONAL SUMMER SCHOOL AND SYMPOSIUM ON MEDICAL DEVICES AND BIOSENSORS, 2008, : 183 - +
  • [2] Design and Development of Continuous Cuff-less Blood Pressure Monitoring Devices
    Griggs, Devon
    Sharma, Manuja
    Naghibi, Arian
    Wallin, Colton
    Ho, Victor
    Barbosa, Karinne
    Ghirmai, Tadesse
    Cao, Hung
    Krishnan, Sandeep K.
    2016 IEEE SENSORS, 2016,
  • [3] CUFF-LESS BLOOD PRESSURE MONITORING DURING SLEEP
    Noda, A.
    Mita, Y.
    Miyata, S.
    Ando, M.
    Okumura, T.
    JOURNAL OF HYPERTENSION, 2019, 37 : E254 - E254
  • [4] CONTINUOUS CUFF-LESS BLOOD PRESSURE PARAMETER MONITORING BY THE OPTICAL SENSOR IN PATIENTS WITH OBSTRUCTIVE SLEEP APNEA SYNDROME
    Yamazaki, M.
    Eda, H.
    Sasou, A.
    Kamiya, A.
    Miyagi, Y.
    Oota, M.
    Takeda, I.
    Takagi, S.
    Matsuura, M.
    Yamashiro, Y.
    SLEEP MEDICINE, 2017, 40 : E352 - E352
  • [5] Continuous cuff-less blood pressure monitoring using vascular elasticity model on photoplethysmogram
    Lin, T. T. L.
    Guo, H. W. G.
    Lee, H. F. L.
    Su, P. Y. S.
    EUROPEAN HEART JOURNAL, 2019, 40 : 402 - 402
  • [6] InstaBP: Cuff-less Blood Pressure Monitoring on Smartphone using Single PPG Sensor
    Dey, Jishnu
    Gaurav, Aman
    Tiwari, Vijay N.
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 5002 - 5005
  • [7] Cuff-Less PPG based Continuous Blood Pressure Monitoring - A Smartphone based Approach
    Gaurav, Aman
    Maheedhar, Maram
    Tiwari, Vijay N.
    Narayanan, Rangavittal
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 607 - 610
  • [8] Cuff-Less Blood Pressure Monitoring System Using Smartphones
    Tabei, Fatemehsadat
    Gresham, Jon Michael
    Askarian, Behnam
    Jung, Kwanghee
    Chong, Jo Woon
    IEEE ACCESS, 2020, 8 : 11534 - 11545
  • [9] THE ACCURACY OF THE NEW CUFF-LESS BLOOD PRESSURE MONITORING SYSTEM
    Shin, Myung-Jun
    Choi, Jung Hyun
    Lee, Byeong-Ju
    Han, Junhee
    Hong, Jungmin
    Hong, Jiwon
    JOURNAL OF HYPERTENSION, 2016, 34 : E511 - E511
  • [10] Cuff-Less Continuous Blood Pressure Monitoring System Using Pulse Transit Time Techniques
    Zaki, Wan Suhaimizan Wan
    Correia, Ricardo
    Korposh, Serhiy
    Hayes-Gill, Barrie R.
    Morgan, Stephen P.
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2016, 8 (01): : 51 - 57