Study on Transient Performance Testing Method of Electronic Current Transformer in Smart Substation

被引:0
|
作者
Wang Xiao-ming [1 ]
Zhou Wei [1 ]
Zhou Ke [1 ]
Li Ming-po [1 ]
Wang Bin [1 ]
机构
[1] GUANGXI Power Grid Co Ltd, Elect Power Res Inst, Nanning, Peoples R China
关键词
Electronic current transformer; Transient performance; Smart substation; RTDS;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Transient performance is an important parameter to measure the performance of electronic current transformer in smart substation, the transient performance of electronic current transformer with analog integrator and digital integrator is analyzed theoretical and simulated, Simulation results show that the transient performance is greatly degraded when integrator parameter or integral algorithm is improperly used. Therefore, it is necessary to test the transient performance. In view of the transient testing limitations of traditional dynamic model test system, a test method based on the technology of RTDS simulation is proposed and the real-time simulation of the transient performance is given, using the method to test the electronic current transformer transient C, the test results show that the method can provide effective reflected in the transient response of the electronic current transformer.
引用
收藏
页码:1638 / 1643
页数:6
相关论文
共 50 条
  • [1] The field calibration method of electronic current transformer in intelligent substation
    Xu, Xianyong
    Fang, Lu
    Ou, Chaolong
    Cheng, Fusheng
    [J]. 2014 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2014,
  • [2] The study of transient performance for electronic current transformer sensor based on Rogowski coil
    Li, Wei
    Yin, Xianggen
    Chen, Deshu
    Zhang, Zhe
    Chen, Wei
    [J]. PROCEEDINGS OF THE 41ST INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1 AND 2, 2006, : 162 - +
  • [3] The Application Key Problem and On-site Test Study of Electronic Transformer in Smart Substation
    Yang Huayun
    Jiang Bo
    Jiang Wei
    Aibing
    Yang Huayun
    [J]. 2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [4] Study of the Electronic Current Transformer's Additional Error Testing
    Yang, Chun-Yan
    Li, Deng-Yun
    Hu, Hao-Liang
    Peng, Hui
    Yao, Li
    Xu, Tao
    [J]. PROCEEDINGS OF THE 3RD ANNUAL INTERNATIONAL CONFERENCE ON ELECTRONICS, ELECTRICAL ENGINEERING AND INFORMATION SCIENCE (EEEIS 2017), 2017, 131 : 143 - 149
  • [5] New Application of Fibre Optical Current Transformer in Smart Retrofit Substation
    Li, Yingjin
    Ma, Yue
    Wang, Wenli
    [J]. ADVANCES IN POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 614-615 : 1846 - 1850
  • [6] COMPUTATION OF CURRENT TRANSFORMER TRANSIENT PERFORMANCE
    POLJAK, M
    KOLIBAS, N
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1988, 3 (04) : 1816 - 1822
  • [7] Correction of current transformer transient performance
    Wiszniewski, Andrzej
    Rebizant, Waldemar
    Schiel, Ludwig
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (02) : 624 - 632
  • [8] Optical Electric Current Transformer for Monitoring Its Performance in the Substation
    Li, Jingxiang
    Lai, Hao
    Liu, Yuchao
    Xia, Xiaopeng
    [J]. JOURNAL OF NANOELECTRONICS AND OPTOELECTRONICS, 2023, 18 (11) : 1302 - 1309
  • [9] Application of the Fiber Optical Current Transformer in the 110kV Smart Substation
    Na, Wang
    Quan, Wan
    [J]. 2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [10] Self-healing Optical Current Transformer and Its Application in Smart Substation
    Yu Wen-bin
    Li Shen-wang
    Zhang Guo-qing
    Guo Zhi-zhong
    Yu Wen-bin
    Zhang Guo-qing
    Wang Gui-zhong
    Guo Zhi-zhong
    [J]. ELECTRONIC INFORMATION AND ELECTRICAL ENGINEERING, 2012, 19 : 340 - 345