Saturation modelling in D-Q axis models of salient pole synchronous machines

被引:96
|
作者
Levi, E [1 ]
机构
[1] Liverpool John Moores Univ, Sch Elect Engn Elect & Phys, Liverpool L3 3AF, Merseyside, England
关键词
D O I
10.1109/60.749146
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Presently available transient d-q axis models of saturated salient pole synchronous machines are derived by selecting either all age winding currents or all the winding nux linkages as state-space variables. This paper presents a number of novel models where state-space variables are selected in various different ways. The idea originates in the 'generalised flux' and 'generalised inductance' concept, which has recently been successfully developed and applied in derivation of numerous models of saturated smooth air-gap a.c, machines. The concept is here extended to salient pole synchronous machines. Saturation itself is accounted for by means of single saturation factor approach and conversion of anisotropic to isotropic machine is executed in the usual way. The new models, presented its the paper, yield the same accuracy as the existing models that are basted an single saturation factor approach, This statement is confirmed by a simulation study and a sample of simulation results is included. However, a number of new models are considerably simpler than the existing ones and thus more convenient for application in simulations.