Assembling a prototype resonance electrical impedance spectroscopy system for breast tissue signal detection: Preliminary assessment

被引:4
|
作者
Sumkin, Jules [1 ]
Zheng, Bin [1 ]
Gruss, Michelle [1 ]
Drescher, John [1 ]
Leader, Joseph [1 ]
Good, Walter [1 ]
Lu, Amy [1 ]
Cohen, Cathy [1 ]
Shah, Ratan [1 ]
Zuley, Margarita [1 ]
Gur, David [1 ]
机构
[1] Univ Pittsburgh, Dept Radiol, Pittsburgh, PA 15213 USA
关键词
electrical impedance spectroscopy; breast cancer; technology assessment;
D O I
10.1117/12.770457
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Using electrical impedance spectroscopy (EIS) technology to detect breast abnormalities in general and cancer in particular has been attracting research interests for decades. Large clinical tests suggest that current EIS systems can achieve high specificity (>= 90%) at a relatively low sensitivity ranging from 15% to 35%. In this study, we explore a new resonance frequency based electrical impedance spectroscopy (REIS) technology to measure breast tissue EIS signals in vivo, which aims to be more sensitive to small tissue changes. Through collaboration between our imaging research group and a commercial company, a unique prototype REIS system has been assembled and preliminary signal acquisition has commenced. This REIS system has two detection probes mounted in the two ends of a Y-shape support device with probe separation of 60 mm. During REIS measurement, one probe touches the nipple and the other touches to an outer point of the breast. The electronic system continuously generates sweeps of multi-frequency electrical pulses ranging from 100 to 4100 kHz. The maximum electric voltage and the current applied to the probes are 1.5V and 30mA, respectively. Once a "record" command is entered, multi-frequency sweeps are recorded every 12 seconds until the program receives a "stop recording" command. In our imaging center, we have collected REIS measurements from 150 women under an IRB approved protocol. The database includes 58 biopsy cases, 78 screening negative cases, and other "recalled" cases (for additional imaging procedures). We measured eight signal features from the effective REIS sweep of each breast. We applied a multi-feature based artificial neural network (ANN) to classify between "biopsy" and normal "non-biopsy" breasts. The ANN performance is evaluated using a leave-one-out validation method and ROC analysis. We conducted two experiments. The first experiment attempted to classify 58 "biopsy" breasts and 58 "non-biopsy" breasts acquired on 58 women each having one breast recommended for biopsy. The second experiment attempted to classify 58 "biopsy'; breasts and 58 negative breasts from the set of screening negative cases. The areas under ROC curves are 0.679 +/- 0.033 and 0.606 +/- 0.035 for the first and the second experiment, respectively. The preliminary results demonstrate (1) even with this rudimentary system with only one paired probes there is a measurable signal of changes in breast tissue demonstrating the feasibility of applying REIS technology for identifying at least some women with highly suspicious breast abnormalities and (2) the electromagnetic asymmetry between two breasts may be more sensitive in detecting changes in the abnormal breast. To further improve the REIS system performance, we are currently designing a new REIS system with multiple electrical probes and a more sophisticated analysis scheme.
引用
收藏
页数:8
相关论文
共 43 条
  • [1] Detection of breast abnormalities using a prototype resonance electrical impedance spectroscopy system: A preliminary study
    Zheng, Bin
    Zuley, Margarita L.
    Sumkin, Jules H.
    Catullo, Victor J.
    Abrams, Gordon S.
    Rathfon, Grace Y.
    Chough, Denise M.
    Gruss, Michelle Z.
    Gur, David
    [J]. MEDICAL PHYSICS, 2008, 35 (07) : 3041 - 3048
  • [2] An electrical impedance spectroscopy system for breast cancer detection
    Saulnier, Gary J.
    Liu, Ning
    Tamma, Chandana
    Xia, Hongjun
    Kao, Tzu-Jen
    Newell, J. C.
    Isaacson, David
    [J]. 2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 4154 - 4157
  • [3] Classification of breast tissue by electrical impedance spectroscopy
    da Silva, JE
    de Sá, JPM
    Jossinet, J
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2000, 38 (01) : 26 - 30
  • [4] Classification of breast tissue by electrical impedance spectroscopy
    J. Estrela da Silva
    J. P. Marques de Sá
    J. Jossinet
    [J]. Medical and Biological Engineering and Computing, 2000, 38 : 26 - 30
  • [5] Breast Tissue Classification based on Electrical Impedance Spectroscopy
    Liu Chang
    Chang Tiantian
    Li Changxing
    [J]. PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY AND MANAGEMENT SCIENCE (ITMS 2015), 2015, 34 : 237 - 240
  • [6] Computerized Detection of Breast Cancer using Resonance-Frequency-based Electrical Impedance Spectroscopy
    Gao, Wei
    Fan, Ming
    Zhao, Weijie
    Zheng, Bin
    Li, Lihua
    [J]. MEDICAL IMAGING 2017: IMAGING INFORMATICS FOR HEALTHCARE, RESEARCH, AND APPLICATIONS, 2017, 10138
  • [7] Resonance-frequency based Electrical Impedance Spectroscopy and Its Detection Sensitivity to Breast Lesions
    Dhurjaty, Sreeram
    Zheng, Bin
    Gur, David
    [J]. MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [8] Fuzzy Ordination of Breast Tissue with Electrical Impedance Spectroscopy Measurements
    Yuvali, Meliz
    Kavalcioglu, Cemal
    Kaba, Serife
    Isin, Ali
    [J]. 10TH INTERNATIONAL CONFERENCE ON THEORY AND APPLICATION OF SOFT COMPUTING, COMPUTING WITH WORDS AND PERCEPTIONS - ICSCCW-2019, 2020, 1095 : 151 - 157
  • [9] Classification of Thyroid Nodules Using a Resonance-Frequency-Based Electrical Impedance Spectroscopy: A Preliminary Assessment
    Zheng, Bin
    Tublin, Mitchell E.
    Klym, Amy H.
    Gur, David
    [J]. THYROID, 2013, 23 (07) : 854 - 862
  • [10] Developing and Testing a Multi-probe Resonance Electrical Impedance Spectroscopy System for Detecting Breast Abnormalities
    Gur, David
    Zheng, Bin
    Dhurjaty, Sreeram
    Wolfe, Gene
    Fradin, Mary
    Weil, Richard
    Sumkin, Jules
    Zuley, Margarita
    [J]. MEDICAL IMAGING 2009: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2009, 7263