EMG variability during maximum voluntary isometric and anisometric contractions is reduced using spatial averaging

被引:17
|
作者
Kasprisin, JE [1 ]
Grabiner, MD [1 ]
机构
[1] Cleveland Clin Educ Fdn, Dept Biomed Engn, Cleveland, OH 44106 USA
关键词
anisometric; elbow; electrodes; EMG; isokinetic; isometric;
D O I
10.1016/S1050-6411(97)00013-8
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Electromyography (EMG) is a commonly used tool that can be plagued with poor signal-to-noise ratios. One result of poor signal-to-noise ratios is increased within-and between-subject variability of quantified EMG variables, for example, the integrated EMG. Methods that reduce within-and between-subject variability of quantified EMG variables can increase the statistical power of an experimental design and aid in the functional interpretation of experimental results. The purpose of this investigation was to determine the effectiveness of spatially averaging the surface EMG signal to reduce the variability of the quantified EMG obtained during maximum voluntary contractions (MVC). The present study extends the work of earlier investigators describing the enhanced signal characteristics obtained by spatially averaging the surface EMG measured during submaximum voluntary isometric contractions and stretch reflexes. Ten subjects performed maximum voluntary isometric and anisometric (concentric and eccentric) contractions of the elbow flexors. Four electrodes, forming two pairs of bipolar electrodes were placed over both the biceps brachii and brachioradialis muscles. Four rectified and integrated EMG signals from the electrode array were compared. Data from each subject's contraction condition and from each muscle were used to compute a coefficient of variation that was considered representative of the within-subject variability. These data were analysed with a multifactorial repeated measures analysis of variance (ANOVA). The results revealed a muscle-specific, statistically significant superiority of one of the methods in reducing the variability of the rectified and integrated EMG signal. Summing the rectified and integrated signals from each bipolar pair of electrodes in the array was shown to reduce significantly the within-subject variability. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:45 / 50
页数:6
相关论文
共 50 条
  • [1] Normalization procedures using maximum voluntary isometric contractions for the serratus anterior and trapezius muscles during surface EMG analysis
    Ekstrom, RA
    Soderberg, GL
    Donatelli, RA
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2005, 15 (04) : 418 - 428
  • [2] Comparison of algorithms for estimation of EMG variables during voluntary isometric contractions
    Farina, D
    Merletti, R
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2000, 10 (05) : 337 - 349
  • [3] A comparison of surface and fine wire EMG recordings of gluteus medius during selected maximum isometric voluntary contractions of the hip
    Semciw, Adam I.
    Neate, Rachel
    Pizzari, Tania
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2014, 24 (06) : 835 - 840
  • [4] Repeatability of surface EMG variables during voluntary isometric contractions of the biceps brachii muscle
    Rainoldi, A
    Galardi, G
    Maderna, L
    Comi, G
    Lo Conte, L
    Merletti, R
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1999, 9 (02) : 105 - 119
  • [5] Selective activation of lower leg muscles during maximum voluntary isometric contractions
    Hagen, Marco
    Schwiertz, Gerrit
    Landorf, Karl B.
    Menz, Hylton B.
    Murley, George S.
    HUMAN MOVEMENT SCIENCE, 2016, 50 : 30 - 37
  • [6] AVERAGED RECTIFIED SMOOTH EMG DURING BRISK MAXIMUM VOLUNTARY MUSCLE CONTRACTIONS
    SECHER, NH
    LARSEN, K
    RUBE, N
    ACTA PHYSIOLOGICA SCANDINAVICA, 1980, 108 (02): : A45 - A45
  • [7] Joint position dependence of weakness during maximum isometric voluntary contractions in subjects with hemiparesis
    Koo, TK
    Mak, AF
    Hung, LK
    Dewald, JP
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2003, 84 (09): : 1380 - 1386
  • [8] Reliability of spike and turn variables of surface EMG during isometric voluntary contractions of the biceps brachii muscle
    Lee, Jin
    Jung, Min-Ye
    Kim, Sung-Hwan
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2011, 21 (01) : 119 - 127
  • [9] Surface EMG signal processing during isometric contractions
    Merletti, R
    LoConte, LR
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1997, 7 (04) : 241 - 250
  • [10] A Multi-pad Electrode EMG System for Studying Muscle Activity during Voluntary Isometric Contractions
    Jankovic, M. M.
    Malesevic, N.
    Popovic, D. B.
    5TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2012, 37 : 773 - 776