Deep-inspiration breath-hold PET/CT versus free breathing PET/CT and respiratory gating PET for reference: evaluation in 95 patients with lung cancer

被引:23
|
作者
Kawano, Tsuyoshi [1 ]
Ohtake, Eiji [1 ]
Inoue, Tomio [2 ]
机构
[1] Kanagawa Canc Ctr, Div Nucl Med, Asahi Ku, Yokohama, Kanagawa 2410815, Japan
[2] Yokohama City Univ, Dept Radiol, Sch Med, Kanazawa Ku, Yokohama, Kanagawa 2360004, Japan
关键词
Deep-inspiration breath-hold; PET/CT; Maximum SUV; Respiratory gating; Lung cancer; MOTION CORRECTION; GATED PET; ARTIFACTS; LESIONS; IMAGES; THORAX; ACQUISITION;
D O I
10.1007/s12149-010-0442-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective The objective of this study was to define the factors that correlate with differences in maximum standardized uptake value (SUV(max)) in deep-inspiration breath-hold (DIBH) and free breathing (FB) PET/CT admixed with respiratory gating (RG) PET for reference. Methods Patients (n = 95) with pulmonary lesions were evaluated at one facility over 33 months. After undergoing whole-body PET/CT, a RG PET and FB PET/CT scans were obtained, followed by a DIBH PET/CT scan. All scans were recorded using a list-mode dynamic collection method with respiratory gating. The RG PET was reconstructed using phase gating without attenuation correction; the FB PET was reconstructed from the RG PET sinogram datasets with attenuation correction. Respiratory motion distance, breathing cycle speed, and waveform of RG PET were recorded. The SUV(max) of FB PET/CT and DIBH PET/CT were recorded: the percent difference in SUV(max) between the FB and DIBH scans was defined as the % BH-index. Results The % BH-index was significantly higher for lesions in the lower lung area than in the upper lung area. Respiratory motion distance was significantly higher in the lower lung area than in the upper lung area. A significant relationship was observed between the % BH-index and respiratory motion distance. Waveforms without steady end-expiration tended to show a high % BH-index. Significant inverse relationships were observed between % BH-index and cycle speed, and between respiratory motion distance and cycle speed. Conclusion Decrease in SUV(max) of FB PET/CT was due to (1) tumor size, (2) distribution of lower lung, (3) long respiratory movement at slow breathing cycle speeds, and (4) respiratory waveforms without steady end-expiration.
引用
下载
收藏
页码:109 / 116
页数:8
相关论文
共 50 条
  • [1] Deep-inspiration breath-hold PET/CT versus free breathing PET/CT and respiratory gating PET for reference: evaluation in 95 patients with lung cancer
    Tsuyoshi Kawano
    Eiji Ohtake
    Tomio Inoue
    Annals of Nuclear Medicine, 2011, 25 : 109 - 116
  • [2] Deep-inspiration breath-hold PET/CT of the thorax
    Nehmeh, Sadek A.
    Erdi, Yusuf E.
    Meirelles, Gustavo S. P.
    Squire, Olivia
    Larson, Steven M.
    Humm, John L.
    Schoder, Heiko
    JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (01) : 22 - 26
  • [3] Deep-inspiration breath-hold PET/CT of lung cancer: Maximum standardized uptake value analysis of 108 patients
    Kawano, Tsuyoshi
    Ohtake, Eiji
    Inoue, Tornio
    JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (08) : 1223 - 1231
  • [4] Baseline FDG PET/CT in free breathing versus deep inspiration breath-hold for pediatric patients with mediastinal lymphoma
    Lundgaard, Anni Young
    Dejanovic, Danijela
    Berthelsen, Anne Kiil
    Andersen, Flemming Littrup
    Rechner, Laura Ann
    Borgwardt, Lise
    Hjalgrim, Lisa Lyngsie
    Specht, Lena
    Maraldo, Maja Vestmo
    ACTA ONCOLOGICA, 2022, 61 (02) : 239 - 246
  • [5] Optimum emission time in deep-inspiration breath-hold PET–CT: a preliminary result
    Koichi Miyashita
    Ukihide Tateishi
    Yuji Nishiyama
    Ryogo Minamimoto
    Kazuya Shizukuishi
    Tomio Inoue
    Annals of Nuclear Medicine, 2010, 24 : 559 - 563
  • [6] 20-s acquisition of deep-inspiration breath-hold PET/CT: Clinical feasibility for imaging of lung cancer
    Torizuka, Tatsuo
    Tanizaki, Yasuo
    Kanno, Toshihiko
    Futatsubashi, Masami
    Yoshikawa, Etsuji
    Okada, Hiroyuki
    Ouchi, Yasuomi
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [7] Single 20-Second Acquisition of Deep-Inspiration Breath-Hold PET/CT: Clinical Feasibility for Lung Cancer
    Torizuka, Tatsuo
    Tanizaki, Yasuo
    Kanno, Toshihiko
    Futatsubashi, Masami
    Yoshikawa, Etsuji
    Okada, Hiroyuki
    Ouchi, Yasuomi
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (10) : 1579 - 1584
  • [8] Fundamental evaluation for optimized imaging methods between respiratory gated PET/CT and deep-inspiration breath hold PET/CT with rapid acquisition
    Yamashita, S.
    Onoguchi, M.
    Hiko, S.
    Yamamoto, H.
    Horita, A.
    Yokoyama, K.
    Tsuji, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S619 - S619
  • [9] Repeatability of FDG PET/CT metrics assessed in free breathing and deep inspiration breath hold in lung cancer patients
    Nygard, Lotte
    Aznar, Marianne C.
    Fischer, Barbara M.
    Persson, Gitte F.
    Christensen, Charlotte B.
    Andersen, Flemming L.
    Josipovic, Mirjana
    Langer, Seppo W.
    Kjaer, Andreas
    Vogelius, Ivan R.
    Bentzen, Soren M.
    AMERICAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 8 (02): : 127 - +
  • [10] Optimum emission time in deep-inspiration breath-hold PET-CT: a preliminary result
    Miyashita, Koichi
    Tateishi, Ukihide
    Nishiyama, Yuji
    Minamimoto, Ryogo
    Shizukuishi, Kazuya
    Inoue, Tomio
    ANNALS OF NUCLEAR MEDICINE, 2010, 24 (07) : 559 - 563