A carefully designed study was conducted during the summer of 1998 to collect samples of ambient air by canisters and compare the analysis results to direct sorbent preconcentration results taken at the time of sample collection. Thirty-two 1 h sample sets were taken, each composed of a "near-real-time" sample analyzed by an autoGC-MS XonTech 930/Varian Saturn 2000 system, and Summa and Silco canisters. Hourly total nonmethane organic carbon (TNMOC), ozone, and meteorological measurements were also made. Each canister was analyzed on the autoGC-MS system for a target list of 108 volatile organic compounds (VOCs) and on a manual cryosampling GC-FID system. Comparisons were made between the collection and analysis methods, Because of the low sample loading (150-250 ppbC TNMOC), these comparisons were a stringent test of sample collection and analysis capabilities. The following specific conclusions may be drawn from this study. Reasonable precision (within 15% mean difference of duplicate analyses from the same canister) can be obtained for analyses of target VOCs at low-ppbC concentrations. Relative accuracy between the GC-MS and GC-FID analysis methods is excellent, as demonstrated by comparisons of analyses of the same canisters, if measurements are sufficiently above the detection limits. This is especially significant as the GC-MS and GC-FID were independently calibrated. While statistically significant differences may be observed between the results from canister and near-real-time samples, the differences were generally small and there were clear correlations between the canister results and the near-real-time results. Canister cleanliness limits detection below the EPA Method TO-14 acceptance standard of 0.2 ppbv (0.2-2 ppbC for target analytes).
引用
收藏
页码:166 / 174
页数:9
相关论文
共 50 条
  • [1] Volatile organic compounds: Sampling methods and their worldwide profile in ambient air
    Kumar, Anuj
    Viden, Ivan
    [J]. ENVIRONMENTAL MONITORING AND ASSESSMENT, 2007, 131 (1-3) : 301 - 321
  • [2] Volatile Organic Compounds: Sampling Methods and Their Worldwide Profile in Ambient Air
    Anuj Kumar
    Ivan Víden
    [J]. Environmental Monitoring and Assessment, 2007, 131 : 301 - 321
  • [3] Determination of volatile organic compounds in ambient air - Comparison of methods
    Czaplicka, M
    Klejnowski, K
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 976 (1-2) : 369 - 376
  • [4] Diffusive sampling of volatile organic compounds in ambient air
    Brown, VM
    Crump, DR
    [J]. ENVIRONMENTAL MONITORING AND ASSESSMENT, 1998, 52 (1-2) : 43 - 55
  • [5] Diffusive Sampling of Volatile Organic Compounds in Ambient Air
    V. M. Brown
    D. R. Crump
    [J]. Environmental Monitoring and Assessment, 1998, 52 : 43 - 55
  • [6] Comparison of Measurement Methods for Volatile Organic Compounds in Ambient Air Using Adsorbent Tubes and Canisters
    Baek, Sung-Ok
    Seo, Young-Kyo
    Heo, Gwi-Seok
    Jeon, Chan-Gon
    Lee, Min-do
    Han, Jin-Seok
    [J]. JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2016, 32 (03) : 305 - 319
  • [7] Passive sampling of aromatic volatile organic compounds (VOC) in ambient air in Switzerland
    Monn, C
    Hangartner, M
    [J]. ENVIRONMENTAL TECHNOLOGY, 1996, 17 (03) : 301 - 307
  • [8] Recent Advances in Microextraction Methods for Sampling and Analysis of Volatile Organic Compounds in Air: A Review
    Poormohammadi, Ali
    Bahramy, Abdolrahman
    Giri, Balendu Shekher
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2019, 6 (02): : 253 - 269
  • [9] Miniaturised air sampling techniques for analysis of volatile organic compounds in air
    Lan, Hangzhen
    Hartonen, Kari
    Riekkola, Marja-Liisa
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2020, 126
  • [10] COMPARISON OF TENAX TA AND CARBOTRAP FOR SAMPLING AND ANALYSIS OF VOLATILE ORGANIC-COMPOUNDS IN AIR
    ROTHWEILER, H
    WAGER, PA
    SCHLATTER, C
    [J]. ATMOSPHERIC ENVIRONMENT PART B-URBAN ATMOSPHERE, 1991, 25 (02): : 231 - 235