Swept source optical coherence tomography using an all-fiber 1300-nm ring laser source

被引:148
|
作者
Choma, MA
Hsu, K
Izatt, JA
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
[2] Micron Opt Inc, Atlanta, GA 30345 USA
关键词
optical coherence tomography; medical imaging; biological imaging; tunable lasers; ophthalmic imaging; skin imaging;
D O I
10.1117/1.1961474
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The increased sensitivity of spectral domain optical coherence tomography (OCT) has driven the development of a new generation of technologies in OCT, including rapidly tunable, broad bandwidth swept laser sources and spectral domain OCT interferometer topologies. In this work, the operation of a turnkey 1300-nm swept laser source is demonstrated. This source has a fiber ring cavity with a semiconductor optical amplifier gain medium. Intracavity mode selection is achieved with an in-fiber tunable fiber Fabry-Perot filter. A novel optoelectronic technique that allows for even sampling of the swept source OCT signal in k space also is described. A differential swept source OCT system is presented, and images of in vivo human cornea and skin are presented. Lastly, the effects of analog-to-digital converter aliasing on image quality in swept source OCT are discussed. (C) 2005 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Single mode fiber based polarization sensitive optical coherence tomography using a swept laser source
    Sharma, P.
    Verma, Y.
    Rao, K. D.
    Gupta, P. K.
    JOURNAL OF OPTICS, 2011, 13 (11)
  • [2] Swept source at 1060 nm for Fourier domain optical coherence tomography
    Zhang, Jun
    Wang, Qiang
    Rao, Bin
    Chen, Zhongping
    Hsu, Kevin
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE XI, 2007, 6429
  • [3] All ceramic "table tops" analyzed using swept source optical coherence tomography
    Stoica, Eniko Tunde
    Marcauteanu, Corina
    Sinescu, Cosmin
    Negrutiu, Meda Lavinia
    Topala, Florin
    Duma, Virgil-Florin
    Bradu, Adrian
    Podoleanu, Adrian Gh.
    HIGH-END MEDICINE BASED ON LASER AND BIOTECHNOLOGIES, 2016, 9670
  • [4] Swept source optical coherence tomography based on scanning fiber probe
    Wu, Tong
    Ding, Zhihua
    Wang, Kai
    Xu, Lei
    Chen, Minghui
    Wang, Chuan
    Guangxue Xuebao/Acta Optica Sinica, 2009, 29 (SUPPL.): : 37 - 41
  • [5] All-fiber ring-cavity based frequency swept laser source for frequency domain OCT
    陈明惠
    丁志华
    徐磊
    吴彤
    王川
    史国华
    张雨东
    ChineseOpticsLetters, 2010, 8 (02) : 202 - 205
  • [6] All-fiber ring-cavity based frequency swept laser source for frequency domain OCT
    Chen, Minghui
    Ding, Zhihua
    Xu, Lei
    Wu, Tong
    Wang, Chuan
    Shi, Guohua
    Mang, Yudong
    CHINESE OPTICS LETTERS, 2010, 8 (02) : 202 - 205
  • [7] Swept Source Optical Coherence Tomography: a Review
    Yasin Alibhai A.
    Or C.
    Witkin A.J.
    Current Ophthalmology Reports, 2018, 6 (1) : 7 - 16
  • [8] Multiband swept laser source for frequency domain optical coherence tomography
    Jiang, Junfeng
    Hui, Rongqing
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIV, 2010, 7554
  • [9] MEMS scanner based swept source laser for optical coherence tomography
    Totsuka, Kouki
    Isamoto, Keiji
    Sakai, Tooru
    Morosawa, Atsushi
    Chong, Changho
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIV, 2010, 7554
  • [10] Laser Lens Size Measurement Using Swept-Source Optical Coherence Tomography
    Jia, Pingping
    Zhao, Hong
    Qin, Yuwei
    APPLIED SCIENCES-BASEL, 2020, 10 (14):