Extending Fluorescence Thermometry to Measuring Wall Surface Temperatures Using Evanescent-Wave Illumination

被引:8
|
作者
Kim, Myeongsub [1 ]
Yoda, Minami [1 ]
机构
[1] Georgia Inst Technol, GW Woodruff Sch Mech Engn, Atlanta, GA 30332 USA
来源
基金
美国国家科学基金会;
关键词
wall surface temperature measurement; fluorescence thermometry; evanescent waves; LASER-INDUCED FLUORESCENCE; CONVECTIVE HEAT-TRANSFER; MICROCHANNELS; FLOWS; FIELD;
D O I
10.1115/1.4004871
中图分类号
O414.1 [热力学];
学科分类号
摘要
Cooling microelectronics with heat flux values of hundreds of kW/cm(2) over hot spots with typical dimensions well below 1 mm will require new single- and two-phase thermal management technologies with micron-scale addressability. However, experimental studies of thermal transport through micro- and mini-channels report a wide range of Nusselt numbers even in laminar single-phase flows, presumably due in part to variations in channel geometry and surface roughness. These variations make constructing accurate numerical models for what would be otherwise straightforward computational simulations challenging. There is, therefore, a need for experimental techniques that can measure both bulk fluid and wall surface temperatures at micron-scale spatial resolution without disturbing the flow in both heat transfer and microfluidics applications. We report here the evaluation of a nonintrusive technique, fluorescence thermometry (FT), to determine wall surface and bulk fluid temperatures with a spatial resolution of O(10 mu m) for water flowing through a heated channel. Fluorescence thermometry is typically used to estimate water temperature fields based on variations in the emission intensity of a fluorophore dissolved in the water. The accuracy of FT can be improved by taking the ratio of the emission signals from two different fluorophores (dual-tracer FT or DFT) to eliminate variations in the signal due to (spatial and temporal) variations in the excitation intensity. In this work, two temperature-sensitive fluorophores, fluorescein and sulforhodamine B, with emission intensities that increase and decrease, respectively, with increasing temperature, are used to further improve the accuracy of the temperature measurements. Water temperature profiles were measured in steady Poiseuille flow at Reynolds numbers of 3.3 and 8.3 through a 1 mm(2) heated minichannel. Water temperatures in the bulk flow (i.e., away from the walls) were measured using DFT with an average uncertainty of 0.2 degrees C at a spatial resolution of 30 mu m. Temperatures within the first 0.3 mu m next to the wall were measured using evanescent-wave illumination of a single temperature-sensitive fluorophore with an average uncertainty of less than 0.2 degrees C at a spatial resolution of 10 mu m. The results are compared with numerical predictions, which suggest that the water temperatures at an average distance of similar to 70 nm from the wall are identical within experimental uncertainty to the wall surface temperature. [DOI: 10.1115/1.4004871]
引用
收藏
页数:8
相关论文
共 50 条
  • [1] FLUORESCENCE THERMOMETRY FOR MEASURING WALL SURFACE AND BULK FLUID TEMPERATURES
    Kim, Myeongsub
    Yoda, Minami
    PROCEEDINGS OF THE ASME INTERNATIONAL HEAT TRANSFER CONFERENCE - 2010, VOL 4: HEAT TRANSFER MEASUREMENT TECHNIQUES, HEAT TRANSFER EQUIPMENT, THERMOELECTRICS, 2010, : 65 - 74
  • [2] Evanescent-Wave Filtering in Images Using Remote Terahertz Structured Illumination
    Flammini, M.
    Pontecorvo, E.
    Giliberti, V.
    Rizza, C.
    Ciattoni, A.
    Ortolani, M.
    DelRe, E.
    PHYSICAL REVIEW APPLIED, 2017, 8 (05):
  • [3] Evanescent-wave fluorescence microscopy using symmetric planar waveguides
    Agnarsson, Bjoern
    Ingthorsson, Saevar
    Gudjonsson, Thorarinn
    Leosson, Kristjan
    OPTICS EXPRESS, 2009, 17 (07): : 5075 - 5082
  • [4] Fluorescence imaging technique of surface electrostatic potential using evanescent wave illumination
    Kazoe, Yutaka
    Miyakawa, Shu
    Miki, Norihisa
    Sato, Yohei
    APPLIED PHYSICS LETTERS, 2009, 95 (23)
  • [5] EVANESCENT-WAVE SPECTROSCOPIC STUDIES OF SURFACE-ENHANCED FLUORESCENCE QUANTUM EFFICIENCIES
    DEMELLO, AJ
    CRYSTALL, B
    RUMBLES, G
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1995, 169 (01) : 161 - 167
  • [6] Wetting observed by evanescent-wave generated fluorescence spectroscopy
    Univ, Sheffield, United Kingdom
    Phys A Stat Theor Phys, 1-2 (225-238):
  • [7] Multiparameter evanescent-wave Imaging in biological fluorescence microscopy
    Oheim, M
    Stühmer, W
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 2002, 38 (02) : 142 - 148
  • [8] Optical resolution below λ/4 using synthetic aperture microscopy and evanescent-wave illumination
    Neumann, Alexander
    Kuznetsova, Yuliya
    Brueck, S. R. J.
    OPTICS EXPRESS, 2008, 16 (25) : 20477 - 20483
  • [9] Model of a fiber-optic evanescent-wave fluorescence sensor
    Woerdeman, DL
    Parnas, RS
    APPLIED SPECTROSCOPY, 2001, 55 (03) : 331 - 337
  • [10] Near-surface velocimetry using evanescent wave illumination
    Jin, S
    Huang, P
    Park, J
    Yoo, JY
    Breuer, KS
    EXPERIMENTS IN FLUIDS, 2004, 37 (06) : 825 - 833