Influence of laboratory homogenization procedures on trace element content of food samples: an ICP-MS study on soft and durum wheat

被引:31
|
作者
Cubadda, F
Baldini, M
Carcea, M
Pasqui, LA
Raggi, A
Stacchini, P
机构
[1] Ist Super Sanita, Lab Alimenti, I-00161 Rome, Italy
[2] Ist Nazl Ric Alimenti & Nutr, Unita Studi Cereali, I-00178 Rome, Italy
来源
FOOD ADDITIVES AND CONTAMINANTS | 2001年 / 18卷 / 09期
关键词
ICP-MS; wheat; trace elements; sample contamination; grinding; milling;
D O I
10.1080/02652030110045353
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Sample contamination as a consequence of abrasion of grinding tools during the homogenization of food materials to be analysed for trace elements was addressed. The possible release of 15 trace elements (Al, As, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Se, Sn, V, Zn) from six different grinding and milling devices, operating either continuously or discontinuously, was evaluated. All the devices were commercially available and were representative of models usually employed in food and agricultural laboratories. Wheat grains belonging to one soft and one durum cultivar were used as test material. The determination of the analyte concentrations in subsamples submitted to the different preparation treatments was performed by quadrupole inductively coupled plasma mass spectrometry (Q-ICP-MS). Accordingly, a suitable digestion method was developed and the ArC+ interference affecting Cr determination was evaluated and corrected. Statistical differences with respect to the control were detected for 10 elements (Al, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb) and in most cases contamination of the samples was traced back to the composition of the grinding equipment. None of the investigated devices was contamination-free with respect to all of the quantified elements. Abrasion of the grinding tools was higher with durum wheat than with soft wheat as a consequence of their different hardness.
引用
收藏
页码:778 / 787
页数:10
相关论文
共 50 条
  • [1] Trace element determinations in food and biological samples using ICP-MS
    Baker, SA
    Bradshaw, DK
    Miller-Ihli, NJ
    ATOMIC SPECTROSCOPY, 1999, 20 (05) : 167 - 173
  • [2] Determination of the Trace Element Content of Fruit Juice Samples by ICP OES and ICP-MS
    Belo de Souza, Max Jose
    Carmen Barciela-Alonso, Maria
    Aboal-Somoza, Manuel
    Bermejo-Barrera, Pilar
    BRAZILIAN JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 9 (35): : 49 - 61
  • [3] Study on Element Distribution in Meteorite Samples by XRF and ICP-MS
    Li Wen-cui
    Yu Zhan
    Fu Yu
    Wu You
    Xin Shi-gang
    Lu Yong
    Zhao Zhen
    Wang Ying
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38 (10) : 3261 - 3263
  • [4] Trace element content of selected fertilizers and dairy manures as determined by ICP-MS
    McBride, MB
    Spiers, G
    COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS, 2001, 32 (1-2) : 139 - 156
  • [5] Classical and New Procedures of Whole Rock Dissolution for Trace Element Determination by ICP-MS
    Cotta, Aloisio J. B.
    Enzweiler, Jacinta
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2012, 36 (01) : 27 - 50
  • [6] Thermodynamic Study of Ga Extraction for Trace Element Analysis by ICP-MS
    Min, Kyungjean
    Johnson, David
    Trumble, Kevin
    RARE METAL TECHNOLOGY 2018, 2018, : 157 - 164
  • [7] New trace element and REE data in thirteen GSF reference samples by ICP-MS
    Balaram, V
    Ramesh, SL
    Anjaiah, KV
    GEOSTANDARDS NEWSLETTER, 1996, 20 (01): : 71 - 78
  • [8] Preparation of Food Samples Using Homogenization and Microwave-Assisted Wet Acid Digestion for Multi-Element Determination with ICP-MS
    Rantasa, Matjaz
    Majer, David
    Finsgar, Matjaz
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2023, (202):
  • [10] Application of ICP-MS trace element analysis in study of ancient Chinese ceramics
    Li, BP
    Zhao, JX
    Collerson, KD
    Greig, A
    CHINESE SCIENCE BULLETIN, 2003, 48 (12): : 1219 - 1224