Endoscopic ultrasound-guided elastography in the nodal staging of oesophageal cancer

被引:30
|
作者
Paterson, Stuart
Duthie, Fraser [1 ]
Stanley, Adrian J. [2 ]
机构
[1] Glasgow Royal Infirm, Dept Pathol, Glasgow G4 0SF, Lanark, Scotland
[2] Glasgow Royal Infirm, Dept Gastroenterol, Glasgow G4 0SF, Lanark, Scotland
关键词
Endoscopic ultrasound; Oesophageal cancer; Lymph nodes; Elastography; Tumour staging; FINE-NEEDLE-ASPIRATION; LYMPH-NODES; TRANSIENT ELASTOGRAPHY; EUS ELASTOGRAPHY; VIRTUAL BIOPSY; DIAGNOSIS; LYMPHADENOPATHY; ACCURACY; METAANALYSIS; LESIONS;
D O I
10.3748/wjg.v18.i9.889
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
AIM: To assess quantitative endoscopic ultrasound (EUS)-guided elastography in the nodal staging of oesophagogastric cancers. METHODS: This was a single tertiary centre study assessing 50 patients with established oesophago-gastric cancer undergoing EUS-guided fine needle aspiration biopsy (FNAB) of lymph nodes between July 2007 and July 2009. EUS-guided elastography of lymph nodes was performed before EUS-FNAB. Standard EUS characteristics were also described. Cytological determination of whether a lymph node was malignant or benign was used as the gold standard for this study. Comparisons of elastography and standard EUS characteristics were made between the cytologically benign and malignant nodes. The main outcome measure was the accuracy of elastography in differentiating between benign and malignant lymph nodes in oesophageal cancers. RESULTS: EUS elastography and FNAB were performed on 53 lymph nodes. Cytological malignancy was found in 23 nodes, one was indeterminate, one was found to be a gastrointestinal stromal tumor and 25 of the nodes were negative for malignancy. On 3 occasions insufficient material was obtained for analysis. The area under the curve for the receiver operating characteristic curve for elastography strain ratio was 0.87 (P < 0.0001). Elastography strain ratio had a sensitivity 83%, specificity 96%, positive predictive value 95%, and negative predictive value 86% for distinguishing between malignant and benign nodes. The overall accuracy of elastography strain ratio was 90%. Elastography was more sensitive and specific in determining malignant nodal disease than standard EUS criteria. CONCLUSION: EUS elastography is a promising modality that may complement standard EUS and help guide EUS-FNAB during staging of upper gastrointestinal tract cancer. (C) 2012 Baishideng. All rights reserved.
引用
收藏
页码:889 / 895
页数:7
相关论文
共 50 条
  • [1] Endoscopic ultrasound-guided elastography in the nodal staging of oesophageal cancer
    Stuart Paterson
    Fraser Duthie
    Adrian J Stanley
    [J]. World Journal of Gastroenterology, 2012, (09) : 889 - 895
  • [2] Quantitative endoscopic ultrasound elastography in the nodal staging of esophageal cancer
    Ramirez-Ramirez, M. A.
    Martinez-Garcia, C. L.
    Zaragoza-Serna, I.
    Zamorano-Orozco, Y.
    [J]. REVISTA DE GASTROENTEROLOGIA DE MEXICO, 2014, 79 (04): : 296 - 299
  • [3] Combined endobronchial and endoscopic ultrasound-guided fine needle aspiration for mediastinal nodal staging of lung cancer
    Ohnishi, R.
    Yasuda, I.
    Kato, T.
    Tanaka, T.
    Kaneko, Y.
    Suzuki, T.
    Yasuda, S.
    Sano, K.
    Doi, S.
    Nakashima, M.
    Hara, T.
    Tsurumi, H.
    Murakami, N.
    Moriwaki, H.
    [J]. ENDOSCOPY, 2011, 43 (12) : 1082 - 1089
  • [4] Endoscopic ultrasound-guided fine needle aspiration is useful for nodal staging in patients with pleural mesothelioma
    Bean, Sarah M.
    Eloubeidi, Mohamad A.
    Cerfolio, Robert
    Chhieng, David C.
    Eltoum, Isam A.
    [J]. DIAGNOSTIC CYTOPATHOLOGY, 2008, 36 (01) : 32 - 37
  • [5] Endoscopic ultrasound-guided fine needle aspiration in the staging of rectal cancer.
    Park, HH
    Nguyen, PT
    Tran, Q
    Chang, KJ
    [J]. GASTROINTESTINAL ENDOSCOPY, 2000, 51 (04) : AB171 - AB171
  • [6] Rapid on site evaluation with oesophageal ultrasound-guided FNA in the diagnosis and staging of metastatic lung cancer
    Obaidee, S.
    Tang, W.
    Raja, S. V.
    McCrudden, R.
    Maddox, A. J.
    Barlow, A. B. T.
    [J]. LUNG CANCER, 2015, 87 : S14 - S15
  • [7] Lung Cancer Staging by Endoscopic and Endobronchial Ultrasound-Guided Fine-Needle Aspiration
    Gottlieb, Klaus
    Wallace, Michael B.
    [J]. ARCHIVOS DE BRONCONEUMOLOGIA, 2009, 45 (12): : 603 - 610
  • [8] ENDOSCOPIC ULTRASOUND-GUIDED TRUCUT BIOPSY FOR EVALUATION OF MEDIASTINAL LYMPHADENOPATHY AND LUNG CANCER STAGING
    Sovani, M. P.
    Jameson, M.
    Thomas, T.
    Ragunath, K.
    Aital, G.
    [J]. THORAX, 2008, 63 : A68 - A69
  • [9] FEASIBILITY OF USING SELECTIVE ENDOSCOPIC ULTRASOUND FOR STAGING OF OESOPHAGEAL CANCER
    Farag, Maged F.
    Lo, Ning
    Abdelrahman, Tarig
    Abdeldayem, Mahmoud A.
    Bowen, Rhiannon
    Havard, Tim
    Escofet, Xavier
    Willicombe, Anita
    [J]. GASTROENTEROLOGY, 2017, 152 (05) : S1285 - S1285
  • [10] Feasibility of using Selective Endoscopic Ultrasound for staging of Oesophageal cancer
    Farag, M.
    Lo, N.
    Abdelrahman, T.
    Havard, T.
    Escofet, X.
    [J]. BRITISH JOURNAL OF SURGERY, 2017, 104 : 37 - 38