A spectrometer with baseline correction and fast pulse pile-up rejection for prompt gamma neutron activation analysis technology

被引:18
|
作者
Zhong, Xiaodong [1 ,2 ]
Chen, Lian [1 ,2 ]
Wang, Baochen [1 ,2 ]
Jin, Ge [1 ,2 ]
机构
[1] Univ Sci & Technol China, State Key Lab Particle Detect & Elect, Hefei 230026, Anhui, Peoples R China
[2] Univ Sci & Technol China, Dept Modern Phys, Hefei 230026, Anhui, Peoples R China
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2018年 / 89卷 / 12期
基金
美国国家科学基金会;
关键词
RESTORER;
D O I
10.1063/1.5049517
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The prompt gamma neutron activation analysis (PGNAA) technology is an online nondestructive material analysis technology widely used in industries. In order to achieve real-time measurements, the gamma ray count rate should reach 400 kcps. Due to the limitation of the detector's decay time, the signal output from the detector is heavily piled up. Meanwhile, the industrial site has a temperature fluctuation of 0-50 degrees C, causing the peak drift in the energy spectrum. This paper presents a readout electronic system specified for PGNAA and proposes series of algorithms that are dedicated for the gamma-ray spectrometric system. The system can achieve a count rate of 400 kcps, and it overcomes poor resolution, spectral distortion, and peak position shift, which are caused by pulse pileups and temperature fluctuations. Published by AIP Publishing.
引用
收藏
页数:8
相关论文
共 29 条
  • [1] Pile-Up Correction for Inelastic Gamma-Ray Detection in Pulsed Fast Neutron Analysis
    Bae, Junwoo
    Graham, Colton
    Clarke, Shaun
    Pozzi, Sara
    Jovanovic, Igor
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2024, 71 (07) : 1420 - 1428
  • [2] Implementation and Performance Analysis of Pulse Pile-up Correction Algorithm on DSP architecture
    Chi, Tao
    Chen, Ming
    Zhang, Dingsong
    PROCEEDINGS OF 2015 IEEE 5TH INTERNATIONAL CONFERENCE ON ELECTRONICS INFORMATION AND EMERGENCY COMMUNICATION, 2015, : 372 - 375
  • [3] Degenerate Pile-up Correction in Pulse Height Spectra from Gamma-ray Spectrometers
    Marcer, Giulia
    Dal Molin, Andrea
    Rebai, Marica
    Rigamonti, Davide
    Tardocchi, Marco
    JOURNAL OF FUSION ENERGY, 2024, 43 (01)
  • [4] PILE-UP REJECTION LIVE-TIME CORRECTION UNIT FOR PRECISION GAMMA-RAY SPECTROMETRY
    ANDAI, A
    JEDLOVSZKY, R
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1983, 34 (02): : 501 - 507
  • [5] PRECISE DETERMINATION OF GE(LI) SPECTROMETER EFFICIENCY AND PRACTICAL ASSESSMENT OF DEAD TIME AND PULSE PILE-UP CORRECTION
    DRYAK, P
    KOKTA, L
    NOVOTNA, P
    RADIOCHEMICAL AND RADIOANALYTICAL LETTERS, 1978, 32 (3-4): : 173 - 179
  • [6] AN EMPIRICAL CORRECTION FOR DEAD-TIME AND PULSE PILE-UP LOSSES IN GAMMA-RAY SPECTROMETRY
    MACWANI, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 225 (01): : 122 - 126
  • [7] Neutron self-shielding correction for prompt gamma neutron activation analysis of large samples
    Blaauw, M
    Belgya, T
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2005, 265 (02) : 257 - 259
  • [8] Neutron self-shielding correction for prompt gamma neutron activation analysis of large samples
    M. Blaauw
    T. Belgya
    Journal of Radioanalytical and Nuclear Chemistry, 2005, 265 : 257 - 259
  • [9] NGD cold-neutron prompt gamma-ray activation analysis spectrometer at NIST
    Paul, Rick L.
    Sahin, Dagistan
    Cook, Jeremy C.
    Brocker, Christoph
    Lindstrom, Richard M.
    O'Kelly, Donna J.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2015, 304 (01) : 189 - 193
  • [10] NGD cold-neutron prompt gamma-ray activation analysis spectrometer at NIST
    Rick L. Paul
    Dağıstan Şahin
    Jeremy C. Cook
    Christoph Brocker
    Richard M. Lindstrom
    Donna J. O’Kelly
    Journal of Radioanalytical and Nuclear Chemistry, 2015, 304 : 189 - 193