Diagnostic Benefit of High b-Value Computed Diffusion-Weighted Imaging in Patients with Hepatic Metastasis

被引:9
|
作者
Ablefoni, Maxime [1 ,2 ]
Surup, Hans [2 ]
Ehrengut, Constantin [2 ]
Schindler, Aaron [3 ]
Seehofer, Daniel [4 ]
Denecke, Timm [2 ]
Meyer, Hans-Jonas [2 ]
机构
[1] Univ Leipzig, Dept Paediat Radiol, Liebigstr 20a, D-04103 Leipzig, Germany
[2] Univ Leipzig, Dept Diagnost & Intervent Radiol, Liebigstr 20, D-04103 Leipzig, Germany
[3] Univ Leipzig, Dept Hepatol, Liebigstr 20, D-04103 Leipzig, Germany
[4] Univ Leipzig, Dept Visceral Transplantat Vasc & Thorac Surg, Liebigstr 20, D-04103 Leipzig, Germany
关键词
computed diffusion-weighted imaging; high b-value; hepatic metastasis; MRI; MRI; METAANALYSIS; CANCER;
D O I
10.3390/jcm10225289
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Diffusion-weighted imaging (DWI) has rapidly become an essential tool for the detection of malignant liver lesions. The aim of this study was to investigate the usefulness of high b-value computed DWI (c-DWI) in comparison to standard DWI in patients with hepatic metastases. In total, 92 patients with histopathologic confirmed primary tumors with hepatic metastasis were retrospectively analyzed by two readers. DWI was obtained with b-values of 50, 400 and 800 or 1000 s/mm(2) on a 1.5 T magnetic resonance imaging (MRI) scanner. C-DWI was calculated with a monoexponential model with high b-values of 1000, 2000, 3000, 4000 and 5000 s/mm(2). All c-DWI images with high b-values were compared to the acquired DWI sequence at a b-value of 800 or 1000 s/mm(2) in terms of volume, lesion detectability and image quality. In the group of a b-value of 800 from a b-value of 2000 s/mm(2), hepatic lesion sizes were significantly smaller than on acquired DWI (metastases lesion sizes b = 800 vs. b 2000 s/mm(2): mean 25 cm(3) (range 10-60 cm(3)) vs. mean 17.5 cm(3) (range 5-35 cm(3)), p < 0.01). In the second group at a high b-value of 1500 s/mm(2), liver metastases were larger than on c-DWI at higher b-values (b = 1500 vs. b 2000 s/mm(2), mean 10 cm(3) (range 4-24 cm(3)) vs. mean 9 cm(3) (range 5-19 cm(3)), p < 0.01). In both groups, there was a clear reduction in lesion detectability at b = 2000 s/mm(2), with hepatic metastases being less visible compared to c-DWI images at b = 1500 s/mm(2) in at least 80% of all patients. Image quality dropped significantly starting from c-DWI at b = 3000 s/mm(2). In both groups, almost all high b-values images at b = 4000 s/mm(2) and 5000 s/mm(2) were not diagnostic due to poor image quality. High c-DWI b-values up to b = 1500 s/mm(2) offer comparable detectability for hepatic metastases compared to standard DWI. Higher b-value images over 2000 s/mm(2) lead to a noticeable reduction in imaging quality, which could hamper diagnosis.
引用
下载
收藏
页数:12
相关论文
共 50 条
  • [1] Diagnostic benefit of high b-value computed diffusion-weighted imaging in acute brainstem infarction
    Ablefoni, Maxime
    Ullrich, Sebastian
    Surov, Alexey
    Hoffmann, Karl-Titus
    Meyer, Hans-Jonas
    JOURNAL OF NEURORADIOLOGY, 2022, 49 (01) : 47 - 52
  • [2] Potential diagnostic value of high b-value computed diffusion-weighted imaging in hepatocellular carcinoma
    Ablefoni, Maxime
    Richter, Theresa
    Leonhardi, Jakob
    Ehrengut, Constantin
    Prasse, Gordian
    Mehdorn, Matthias
    Seehofer, Daniel
    Hoehn, Anne Kathrin
    Denecke, Timm
    Meyer, Hans-Jonas
    CLINICAL AND EXPERIMENTAL HEPATOLOGY, 2024, 10 (02) : 129 - 136
  • [3] Diagnostic value of computed high b-value whole-body diffusion-weighted imaging for primary prostate cancer
    Arita, Yuki
    Yoshida, Soichiro
    Waseda, Yuma
    Takahara, Taro
    Ishii, Chikako
    Ueda, Ryo
    Kwee, Thomas C.
    Miyahira, Kei
    Ishii, Ryota
    Okuda, Shigeo
    Jinzaki, Masahiro
    Fujii, Yasuhisa
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 137
  • [4] Evaluation of the impact of computed high b-value diffusion-weighted imaging on prostate cancer detection
    Sadhna Verma
    Saradwata Sarkar
    Jason Young
    Rajesh Venkataraman
    Xu Yang
    Anil Bhavsar
    Nilesh Patil
    James Donovan
    Krishnanath Gaitonde
    Abdominal Radiology, 2016, 41 : 934 - 945
  • [5] Magnetic Resonance Imaging of Peritoneal Carcinomatosis: Evaluation of High b-Value Computed Diffusion-Weighted Imaging
    Ablefoni, Maxime
    Leonhardi, Jakob
    Ehrengut, Constantin
    Mehdorn, Matthias
    Sucher, Robert
    Gockel, Ines
    Denecke, Timm
    Meyer, Hans-Jonas
    CURRENT ONCOLOGY, 2022, 29 (07) : 4593 - 4603
  • [6] Evaluation of the impact of computed high b-value diffusion-weighted imaging on prostate cancer detection
    Verma, Sadhna
    Sarkar, Saradwata
    Young, Jason
    Venkataraman, Rajesh
    Yang, Xu
    Bhavsar, Anil
    Patil, Nilesh
    Donovan, James
    Gaitonde, Krishnanath
    ABDOMINAL RADIOLOGY, 2016, 41 (05) : 934 - 945
  • [7] How to Improve the Conspicuity of Breast Tumors on Computed High b-value Diffusion-weighted Imaging
    Tamura, Takayuki
    Takasu, Miyuki
    Higaki, Toru
    Yokomachi, Kazushi
    Akiyama, Yuji
    Sumida, Hiroomi
    Nagata, Yasushi
    Awai, Kazuo
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2019, 18 (02) : 119 - 125
  • [8] High b-value diffusion-weighted imaging in progressive multifocal leukoencephalopathy in HIV patients
    Claudia Godi
    Enrico De Vita
    Enrico Tombetti
    Indran Davagnanam
    Lewis Haddow
    Hans Rolf Jäger
    European Radiology, 2017, 27 : 3593 - 3599
  • [9] High b-value diffusion-weighted imaging of acute brain infarction
    Aihara, Hiroshi
    Ohnishi, Manabu
    Kadota, Tomohito
    Abe, Tomoyasu
    Nishio, Shinsaku
    Kawauti, Masamitsu
    Matsumoto, Yuzo
    NEUROLOGICAL SURGERY, 2006, 34 (12): : 1225 - 1230
  • [10] High b-value diffusion-weighted imaging in progressive multifocal leukoencephalopathy in HIV patients
    Godi, Claudia
    De Vita, Enrico
    Tombetti, Enrico
    Davagnanam, Indran
    Haddow, Lewis
    Jager, Hans Rolf
    EUROPEAN RADIOLOGY, 2017, 27 (09) : 3593 - 3599