An echocardiographic and magnetic resonance imaging comparative study of right ventricular volume determination

被引:19
|
作者
Aebischer, N
Meuli, R
Jeanrenaud, X
Koerfer, J
Kappenberger, L
机构
[1] Univ Lausanne, Sch Med, Div Cardiol, Lausanne, Switzerland
[2] Univ Lausanne, Sch Med, Dept Radiol, Lausanne, Switzerland
来源
关键词
right ventricular volume; echocardiography; magnetic resonance;
D O I
10.1023/A:1006055512362
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Assessment of right ventricular volume and function is important in many clinical settings involving heart or lung disease. However, the complexity of the right ventricular anatomy has prevented accurate volume determination by two-dimensional echocardiography. In the present study, 5 models :incorporating standard echocardiographic views, were used to determine right ventricular volume in 10 human subjects. Two models were contingent on the true crescentic appearance of the right ventricle, whereas the remaining 3 calculated the right ventricular volume as a pyramid, an ellipsoid or other tapering geometrical figures, respectively. Subsequently, echocardiographic right ventricular volumes were compared to magnetic resonance imaging derived volumes. Correlation analysis and agreement measurement between the echocardiographic and magnetic resonance end-diastolic volume were performed in 10 out of 10 subjects and in 9 out of 10 subjects for the end-systolic volume. The 2 crescentic models resulted in the most reliable estimation of right ventricular volume. Those findings suggest that models based on right ventricular anatomical landmarks are feasible and should be preferred in echocradiographic studies.
引用
收藏
页码:271 / 278
页数:8
相关论文
共 50 条
  • [1] An echocardiographic and magnetic resonance imaging comparative study of right ventricular volume determination
    Nicole Aebischer
    Reto Meuli
    Xavier Jeanrenaud
    Jacques Koerfer
    Lukas Kappenberger
    The International Journal of Cardiac Imaging, 1998, 14 : 271 - 278
  • [2] Echocardiographic indices of right ventricular systolic function: a cardiac magnetic resonance comparative study
    Leong, D.
    Khurana, S.
    Molaee, P.
    Shipp, N.
    Penhall, A.
    Perry, R.
    Shirazi, M.
    Chakrabarty, A.
    Joseph, M.
    Selvanayagam, J. B.
    EUROPEAN HEART JOURNAL, 2010, 31 : 749 - 749
  • [4] Comparison of echocardiographic parameters with cardiac magnetic resonance imaging in the assessment of right ventricular function
    Agasthi, Pradyumna
    Chao, Chieh-Ju
    Siegel, Robert J.
    Pujari, Sai Harika
    Mookadam, Farouk
    Venepally, Nithin R.
    Wang, Panwen
    Ashraf, Hasan
    Marcotte, Francois
    Brown, Lisa
    Semkiv, Oksana I.
    Fath, Ayman R.
    Allam, Mohamed N. A.
    Jokerst, Clinton E.
    Arsanjani, Reza
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2020, 37 (11): : 1792 - 1802
  • [5] VENTRICULAR SEPTUM IN RIGHT VENTRICULAR VOLUME OVERLOAD - ECHOCARDIOGRAPHIC STUDY
    MEYER, RA
    BENZING, G
    SCHWARTZ, DC
    KAPLAN, S
    AMERICAN JOURNAL OF CARDIOLOGY, 1972, 30 (04): : 349 - &
  • [6] Echocardiographic Linear Dimensions for Assessment of Right Ventricular Chamber Volume as Demonstrated by Cardiac Magnetic Resonance
    Kim, Jiwon
    Srinivasan, Aparna
    Seoane, Tania
    Di Franco, Antonino
    Peskin, Charles S.
    McQueen, David M.
    Paul, Tracy K.
    Feher, Attila
    Geevarghese, Alexi
    Rozenstrauch, Meenakshi
    Devereux, Richard B.
    Weinsaft, Jonathan W.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2016, 29 (09) : 861 - 870
  • [7] Accuracy of right ventricular volume and function assessed with cardiovascular magnetic resonance: comparison with echocardiographic parameters
    Couto, Miguel
    Souto, Miguel
    Martinez, Amparo
    Maceira, Alicia
    Vieira, Cecilia
    Pumar, Jose M.
    Croisille, Pierre
    CLINICAL IMAGING, 2020, 59 (01) : 61 - 67
  • [8] Three-dimensional echocardiographic measurement of right ventricular volume in children with congenital heart disease validated by magnetic resonance imaging
    Papavassiliou, DP
    Parks, WJ
    Hopkins, KL
    Fyfe, DA
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1998, 11 (08) : 770 - 777
  • [9] Determination of Right Ventricular Volume by Combining Echocardiographic Distance Measurements
    Jorstig, Stina
    Waldenborg, Micael
    Liden, Mats
    Wodecki, Maciej
    Thunberg, Per
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2016, 33 (06): : 844 - 853
  • [10] Teamwork using strain imaging in the echocardiographic assessment of right ventricular systolic function: A cardiac magnetic resonance imaging correlation study
    Xu, Bo
    Grimm, Richard A.
    Jellis, Christine L.
    Collier, Patrick
    Desai, Milind Y.
    Phelan, Dermot
    Thamilarasan, Maran
    Rodriguez, Luis Leonardo
    Flamm, Scott D.
    Sato, Kimi
    Harb, Serge C.
    Popovic, Zoran B.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2019, 36 (01): : 94 - 101