Image-domain Noise Reduction with Multiscale Decomposition and Anisotropic Diffusion

被引:0
|
作者
Tang, Shaojie [1 ,2 ]
Yang, Yi [7 ]
Gong, Yan [3 ]
Huang, Kuidong [4 ]
Niu, Tianye [5 ,6 ]
Tang, Xiangyang [7 ]
机构
[1] Xian Univ Posts & Telecommun, Sch Automat, Xian 710121, Shaanxi, Peoples R China
[2] Zhejiang Univ, Sir Run Run Shaw Hosp, Sch Med, Hangzhou 310016, Zhejiang, Peoples R China
[3] Zhejiang Univ, Coll Biomed Engn & Instrument Sci, Hangzhou 310009, Zhejiang, Peoples R China
[4] Northwestern Polytech Univ, Minist Educ, Key Lab Contemporary Design & Integrated Mfg Tech, Xian 710072, Shaanxi, Peoples R China
[5] Zhejiang Univ, Sir Run Run Shaw Hosp, Hangzhou 310009, Zhejiang, Peoples R China
[6] Zhejiang Univ, Inst Translat Med, Hangzhou 310009, Zhejiang, Peoples R China
[7] Emory Univ, Dept Radiol & Imaging Sci, Sch Med, Atlanta, GA 30322 USA
基金
中国国家自然科学基金;
关键词
WEIGHTED LEAST-SQUARES; SCALE-SPACE; COMPUTED-TOMOGRAPHY; RECONSTRUCTION;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Noise reduction in x-ray computed tomography (CT) is a critical technique for improving the diagnostic quality and saving radiation dose. Here, we propose an image-domain multiscale decomposition and anisotropic diffusion based noise reduction method for clinical CT applications. As used in the projection domain, a practical multiscale decomposition of CT image is first carried out using isotropic diffusion partial differential equation (PDE) in the image domain. Then, the image-domain anisotropic diffusion is adopted to reduce noise in each scale. Finally, in order to compensate for the degradation of image sharpness, an edge compensation step is followed. The performance of the proposed image-domain method for noise reduction is experimentally evaluated and verified using the scan data of an anthropomorphic head phantom acquired by a CT scanner. The preliminary result shows that the proposed image-domain multiscale decomposition-based anisotropic diffusion performs very well in noise reduction.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Noise Suppression in Image-Domain Multimaterial Decomposition for Dual-Energy CT
    Jiang, Y.
    Xue, Y.
    Yang, P.
    Xu, L.
    Luo, C.
    Yang, C.
    Niu, T.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E408 - E408
  • [2] Noise Suppression in Image-Domain Material Decomposition for Triple-Energy CT
    Niu, S.
    Zhong, Y.
    Huang, X.
    Zhang, Y.
    Ma, J.
    Wang, J.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E674 - E675
  • [3] Multiscale stategies in automatic image-domain waveform tomography
    Liu, Yujin
    Li, Zhenchun
    [J]. JOURNAL OF EARTH SCIENCE, 2015, 26 (04) : 577 - 585
  • [4] Multiscale Stategies in Automatic Image-Domain Waveform Tomography
    Yujin Liu
    Zhenchun Li
    [J]. Journal of Earth Science, 2015, (04) : 577 - 585
  • [5] Multiscale stategies in automatic image-domain waveform tomography
    Yujin Liu
    Zhenchun Li
    [J]. Journal of Earth Science, 2015, 26 : 577 - 585
  • [6] Multiscale Stategies in Automatic Image-Domain Waveform Tomography
    Yujin Liu
    Zhenchun Li
    [J]. Journal of Earth Science., 2015, 26 (04) - 585
  • [7] Noise Suppression in Image-Domain Multi-Material Decomposition for Dual-Energy CT
    Jiang, Yangkang
    Xue, Yi
    Lyu, Qihui
    Xu, Lei
    Luo, Chen
    Yang, Pengfei
    Yang, Chunlin
    Wang, Jing
    Hu, Xi
    Zhang, Xiaoqun
    Sheng, Ke
    Niu, Tianye
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (02) : 523 - 535
  • [8] Multiscale Penalized Weighted Least-Squares Image-domain Decomposition for Dual-energy CT
    Tang, Shaojie
    Yang, Meili
    Hu, Xiuhua
    Niu, Tianye
    [J]. 2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [9] Iterative image-domain decomposition for dual-energy CT
    Niu, Tianye
    Dong, Xue
    Petrongolo, Michael
    Zhu, Lei
    [J]. MEDICAL PHYSICS, 2014, 41 (04)
  • [10] Iterative Image-Domain Decomposition for Dual-Energy CT
    Niu, T.
    Dong, X.
    Petrongolo, M.
    Zhu, L.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 475 - 476