Implantation of the Syncardia Total Artificial Heart

被引:9
|
作者
Tang, Daniel G. [1 ]
Shah, Keyur B. [2 ]
Hess, Micheal L. [2 ]
Kasirajan, Vigneshwar [1 ]
机构
[1] Virginia Commonwealth Univ, Div Cardiothorac Surg, Richmond, VA 23284 USA
[2] Virginia Commonwealth Univ, Div Cardiol, Richmond, VA 23284 USA
来源
关键词
Medicine; Issue; 89; mechanical circulatory support; total artificial heart; biventricular failure; operative techniques; VENTRICULAR ASSIST DEVICE; RISK SCORE; BRIDGE;
D O I
10.3791/50377
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
With advances in technology, the use of mechanical circulatory support devices for end stage heart failure has rapidly increased. The vast majority of such patients are generally well served by left ventricular assist devices (LVADs). However, a subset of patients with late stage biventricular failure or other significant anatomic lesions are not adequately treated by isolated left ventricular mechanical support. Examples of concomitant cardiac pathology that may be better treated by resection and TAH replacement includes: post infarction ventricular septal defect, aortic root aneurysm / dissection, cardiac allograft failure, massive ventricular thrombus, refractory malignant arrhythmias (independent of filling pressures), hypertrophic / restrictive cardiomyopathy, and complex congenital heart disease. Patients often present with cardiogenic shock and multi system organ dysfunction. Excision of both ventricles and orthotopic replacement with a total artificial heart (TAH) is an effective, albeit extreme, therapy for rapid restoration of blood flow and resuscitation. Perioperative management is focused on end organ resuscitation and physical rehabilitation. In addition to the usual concerns of infection, bleeding, and thromboembolism common to all mechanically supported patients, TAH patients face unique risks with regard to renal failure and anemia. Supplementation of the abrupt decrease in brain natriuretic peptide following ventriculectomy appears to have protective renal effects. Anemia following TAH implantation can be profound and persistent. Nonetheless, the anemia is generally well tolerated and transfusion are limited to avoid HLA sensitization. Until recently, TAH patients were confined as inpatients tethered to a 500 Ib pneumatic console driver. Recent introduction of a backpack sized portable driver (currently under clinical trial) has enabled patients to be discharged home and even return to work. Despite the profound presentation of these sick patients, there is a 79-87% success in bridge to transplantation.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Heart transplantation after SynCardia® total artificial heart implantation
    Morshuis, Michiel
    Rojas, Sebastian, V
    Hakim-Meibodi, Kavous
    Razumov, Artyom
    Gummert, Jan F.
    Schramm, Rene
    [J]. ANNALS OF CARDIOTHORACIC SURGERY, 2020, 9 (02) : 98 - 103
  • [2] SynCardia: the total artificial heart
    Torregrossa, Gianluca
    Anyanwu, Anelechi
    Zucchetta, Fabio
    Gerosa, Gino
    [J]. ANNALS OF CARDIOTHORACIC SURGERY, 2014, 3 (06) : 612 - 620
  • [3] Virtual implantation of the 50cc SynCardia total artificial heart
    Moore, Ryan A.
    Lorts, Angela
    Madueme, Peace C.
    Taylor, Michael D.
    Morales, David L. S.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (06): : 824 - 827
  • [4] SynCardia, total artificial heart, as a bridge to transplant
    Hulman, M.
    Artemiou, P.
    Hudec, V
    Olejarova, I
    Goncalvesova, E.
    [J]. BRATISLAVA MEDICAL JOURNAL-BRATISLAVSKE LEKARSKE LISTY, 2019, 120 (05): : 325 - 330
  • [5] SynCardia Total Artificial Heart Update and Future
    Copeland, Jack G.
    [J]. TEXAS HEART INSTITUTE JOURNAL, 2013, 40 (05) : 587 - 588
  • [6] Prone Position with the Syncardia Total Artificial Heart
    Tannouri, Sami
    Pitcher, Harrison
    Cavarocchi, Nicholas
    Hirose, Hitoshi
    [J]. CRITICAL CARE MEDICINE, 2013, 41 (12)
  • [7] Pathology of the SynCardia Total Artificial Heart: A Case Series
    Glass, Carolyn
    Padera, Robert
    [J]. LABORATORY INVESTIGATION, 2015, 95 : 78A - 78A
  • [8] Pathology of the SynCardia Total Artificial Heart: A Case Series
    Glass, Carolyn
    Padera, Robert
    [J]. MODERN PATHOLOGY, 2015, 28 : 78A - 78A
  • [9] Experience with the SynCardia total artificial heart in a Canadian centre
    Nguyen, Anthony
    Pellerin, Michel
    Perrault, Louis P.
    White, Michel
    Ducharme, Anique
    Racine, Normand
    Carrier, Michel
    [J]. CANADIAN JOURNAL OF SURGERY, 2017, 60 (06) : 375 - 379
  • [10] Renal Dysfunction Following Syncardia Total Artificial Heart Implantation Does Not Affect Survival Following Heart Transplantation
    Kalya, A.
    Boyle, K.
    Goel, R.
    Arabia, F.
    Pajaro, O.
    Scott, R.
    Gopalan, R.
    Jaroszewski, D.
    Kasper, D.
    Wu, Q.
    Staley, L.
    Pierce, C.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2012, 31 (04): : S197 - S197